Pulse pile-up identification and reconstruction for liquid scintillator based neutron detectors

被引:26
|
作者
Luo, X. L. [1 ,2 ]
Modamio, V. [3 ]
Nyberg, J. [2 ]
Valiente-Dobon, J. J. [3 ]
Nishada, Q. [2 ]
de Angelis, G. [3 ]
Agramunt, J. [4 ]
Egea, F. J. [4 ,5 ]
Erduran, M. N. [6 ]
Erturk, S. [7 ]
de France, G. [8 ,9 ]
Gadea, A. [4 ]
Gonzalez, V. [5 ]
Goasduff, A. [10 ]
Huyuk, T. [4 ]
Jaworski, G. [11 ,12 ]
Moszynski, M. [12 ,13 ]
Di Nitto, A. [14 ]
Palacz, M. [12 ]
Soederstroem, P. -A. [15 ,16 ]
Sanchis, E. [5 ]
Triossi, A. [3 ]
Wadsworth, R. [17 ]
机构
[1] Acad Mil Med Sci, Natl Innovat Inst Def Technol, Beijing 100010, Peoples R China
[2] Uppsala Univ, Dept Phys & Astron, SE-75120 Uppsala, Sweden
[3] Ist Nazl Fis Nucl, Lab Nazl Legnaro, I-35020 Padua, Italy
[4] Univ Valencia, CSIC, IFIC, Valencia, Spain
[5] Univ Valencia, Dept Elect Engn, E-46071 Valencia, Spain
[6] Istanbul Sabahattin Zaim Univ, Fac Engn & Nat Sci, Istanbul, Turkey
[7] Omer Halisdemir Univ, Nigde, Turkey
[8] CEA, DSAM, GANIL, Bd Henri Becquerel,BP 55027, F-14076 Caen 05, France
[9] CNRS, IN2P3, Bd Henri Becquerel,BP 55027, F-14076 Caen 05, France
[10] Univ Padua, Dipartimento Fis & Astron, Padua, Italy
[11] Warsaw Univ Technol, Fac Phys, Ul Koszykowa 75, PL-00662 Warsaw, Poland
[12] Univ Warsaw, Heavy Ion Lab, Ul Pasteura 5A, PL-02093 Warsaw, Poland
[13] Natl Ctr Nucl Res, A Soltana 7, PL-05400 Otwock, Poland
[14] Johannes Gutenberg Univ Mainz, D-55099 Mainz, Germany
[15] Tech Univ Darmstadt, Inst Kernphys, D-64289 Darmstadt, Germany
[16] GSI Helmholtzzentrum Schwerionenforsch GmbH, D-64291 Darmstadt, Germany
[17] Univ York, Dept Phys, York, N Yorkshire, England
基金
瑞典研究理事会;
关键词
Pile-up; Digital; First-order derivative; Neutron-gamma discrimination; Liquid scintillator; ARRAY NEDA; GAMMA DISCRIMINATION; BC501A;
D O I
10.1016/j.nima.2018.03.078
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The issue of pulse pile-up is frequently encountered in nuclear experiments involving high counting rates, which will distort the pulse shapes and the energy spectra. A digital method of off-line processing of pile-up pulses is presented. The pile-up pulses were firstly identified by detecting the downward-going zero-crossings in the first-order derivative of the original signal, and then the constituent pulses were reconstructed based on comparing the pile-up pulse with four models that are generated by combining pairs of neutron and.. standard pulses together with a controllable time interval. The accuracy of this method in resolving the pile-up events was investigated as a function of the time interval between two pulses constituting a pile-up event. The obtained results show that the method is capable of disentangling two pulses with a time interval among them down to 20 ns, as well as classifying them as neutrons or gamma rays. Furthermore, the error of reconstructing pile-up pulses could be kept below 6% when successive peaks were separated by more than 50 ns. By applying the method in a high counting rate of pile-up events measurement of the NEutron Detector Array (NEDA), it was empirically found that this method can reconstruct the pile-up pulses and perform neutron-gamma discrimination quite accurately. It can also significantly correct the distorted pulse height spectrum due to pile-up events.
引用
收藏
页码:59 / 65
页数:7
相关论文
共 50 条
  • [21] Pile-up pulse continuous zone reject method
    Yu, Jie
    Zhou, Jianbin
    Liu, Yi
    Tuo, Xianguo
    Wang, Min
    Zhu, Xing
    APPLIED RADIATION AND ISOTOPES, 2020, 165 (165)
  • [22] PULSE PILE-UP .2. TAILED PULSES
    WILKINSON, DH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 297 (1-2): : 244 - 249
  • [23] DISTORTION OF PULSE HEIGHT SPECTRA BY PILE-UP EFFECT
    WILLIAMSON, JH
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1966, 37 (06): : 736 - +
  • [24] PULSE PILE-UP .1. SHORT PULSES
    WILKINSON, DH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1990, 297 (1-2): : 230 - 243
  • [25] CALCULATION OF PILE-UP DISTORTION IN PULSE HEIGHT SPECTRA
    PAZMAN, A
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1969, (03): : 658 - &
  • [26] PULSE PILE-UP .4. BIPOLAR PULSES
    WILKINSON, DH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 307 (2-3): : 462 - 468
  • [27] Simultaneous photon counting and charge integrating for pulse pile-up correction in paralyzable photon counting detectors
    Treb, Kevin
    Radtke, Jeff
    Culberson, Wesley S.
    Li, Ke
    PHYSICS IN MEDICINE AND BIOLOGY, 2023, 68 (15):
  • [28] Simulation of the pulse pile-up effect on the pulse-height spectrum
    Molodtsov, S. L.
    Gurbich, A. F.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2009, 267 (20): : 3484 - 3487
  • [29] Calibration and Unfolding of the Pulse Height Spectra of Liquid Scintillator-Based Neutron Detectors Using Photon Sources
    谢旭飞
    袁熙
    张兴
    樊铁栓
    陈金象
    李湘庆
    Plasma Science and Technology, 2012, 14 (06) : 553 - 557
  • [30] Pile-up Pulse Recognition Method Based on Ballistic Deficit Shape Feature
    Wang M.
    Zhou J.
    Wang H.
    Wang X.
    Liu Y.
    Hong X.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2024, 58 (01): : 231 - 238