Comparison between Positive and Negative Corona Discharges by Hydrodynamic Plasma Simulations

被引:0
|
作者
Zogning, Calvin [1 ]
Lobry, Jacques [1 ]
Moiny, Francis [1 ]
机构
[1] Univ Mons, Gen Phys Dept, Fac Engn, B-7000 Mons, Belgium
关键词
corona discharge; negative and positive glow discharge; nonthermal hydrodynamic plasma; continuity equation; finite element method; DC CORONA; ELECTRON;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Corona discharges are due to the ionization of the gas between two electrodes when the electric field near one of them is very strong. The lack of a complete understanding of the physical processes in corona discharge in both positive and negative polarity means that interest in corona discharge is still current. In this work, we use a more realistic hydrodynamic plasma model which considers 12 charged species such electron, ions and molecules, and 32 chemical reactions present in the plasma. The digital algorithm based on the finite element method is implemented using the commercial software COMSOL Multiphysics (c). A geometrical configuration of a 1D-axisymmetric wire-cylinder is considered and the set of reactions takes place in the radial direction given the symmetry of the system. The results show that the electron density in the negative corona is four orders of magnitude greater than that in the positive corona. The total number of electrons in the plasma layer of the negative corona is more than 50 times that produced in the positive corona. Under identical temperature and pressure conditions, the weakest corona current in positive polarity, which implies a lower ignition DC voltage. Temperature has an opposite effect on the distribution of the electron density present in the plasma. While the rise in temperature causes a rapid increase in the density of electrons in negative corona, the increase is slower in positive corona. In both cases, the electric field is constant on the conductor surface, however the space charge modifies the local electric field.
引用
收藏
页码:552 / 560
页数:9
相关论文
共 50 条
  • [21] Negative DC Corona Inception in Coaxial Cylinders under Variable Atmospheric Conditions: A Comparison with Positive Corona
    Mikropoulos, P. N.
    Zagkanas, V. N.
    [J]. IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2016, 23 (03) : 1322 - 1330
  • [22] COMPLEX FORM OF CURRENT PULSES IN NEGATIVE CORONA DISCHARGES
    CERNAK, M
    HOSOKAWA, T
    [J]. PHYSICAL REVIEW A, 1991, 43 (02): : 1107 - 1109
  • [23] CHEMICAL ASPECTS OF STREAMER MECHANISM FOR NEGATIVE CORONA DISCHARGES
    Halanda, Juraj
    Zahoranova, Anna
    Kudelcik, Jozef
    Cernak, Mirko
    [J]. CHEMICKE LISTY, 2012, 106 : S1447 - S1449
  • [24] The Optical Diagnosis of Underwater Positive Sparks and Corona Discharges
    Chen Dan
    Zeng Xinwu
    Wang Yibo
    [J]. PLASMA SCIENCE & TECHNOLOGY, 2014, 16 (12) : 1100 - 1105
  • [25] Effects of nonlocality on the dynamics of streamers in positive corona discharges
    Naidis, GV
    [J]. TECHNICAL PHYSICS LETTERS, 1997, 23 (06) : 493 - 494
  • [27] The Optical Diagnosis of Underwater Positive Sparks and Corona Discharges
    陈聃
    曾新吾
    王一博
    [J]. Plasma Science and Technology, 2014, (12) : 1100 - 1105
  • [28] Effects of nonlocality on the dynamics of streamers in positive corona discharges
    G. V. Naidis
    [J]. Technical Physics Letters, 1997, 23 : 493 - 494
  • [29] The Optical Diagnosis of Underwater Positive Sparks and Corona Discharges
    陈聃
    曾新吾
    王一博
    [J]. Plasma Science and Technology, 2014, 16 (12) : 1100 - 1105
  • [30] POSITIVE AND NEGATIVE POINT TO PLANE CORONA
    LOEB, LB
    ENGLISH, WN
    [J]. PHYSICAL REVIEW, 1948, 73 (05): : 532 - 532