Stereotactic 11-gauge directional vacuum-assisted breast biopsy: experience with 249 patients

被引:0
|
作者
Travade, A
Isnard, A
Bagard, C
Bouchet, F
Chouzet, S
Gaillot, A
Vilmant, R
机构
[1] Ctr Republ, Ctr Senol, F-63100 Clermont Ferrand, France
[2] Ctr Republ, Anat Pathol Lab, F-63100 Clermont Ferrand, France
来源
JOURNAL DE RADIOLOGIE | 2002年 / 83卷 / 09期
关键词
breast; breast neoplasms; diagnosis; breast biopsy; mammotome; breast calcifications; specimen radiography;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To assess the value of percutaneous vacuum-assisted core biopsy to improve the diagnosis of non palpable mammographic abnormalities. Materials and methods: A total of 252 core biopsies using an 11G Mammotome(R) were performed in 249 patients. Stereotactic localization was performed in the prone position on a dedicated digital Fischer table. Results: Fifty-one, or 25%, of 200 clusters of microcalcifications corresponded to carcinomas: 126 benign lesions, 23 atypical hyperplasia and LCIS, 31 DCIS, 15 invasive ductal carcinomas, and 4 false negative biopsies. In these 4 last cases, surgery was performed because radiographs of the core biopsy showed no microcalcifications; carcinoma was confirmed at histology of the surgical specimen. Using the BI-RADS system, 7 lesions were category 3, 175 lesions were category 4, and 18 lesions were category 5. From a total of 52 masses, 31 were benign lesions, 2 were borderline lesions, and 19 were invasive carcinomas. From these, 5 lesions were category 3, 31 were category 4, and 16 were category 5. Diagnostic surgical biopsy was avoided in 161 cases (63%), in 152 cases for benign lesions including 151 lesions classified as category 4 lesions and in 9 cases for multifocal or recurrent malignant lesions. Conclusion: When technical pitfalls are avoided and when presence of microcalcifications in the core biopsy sample is verified, vacuum assisted core biopsy with Mammotome(R) 11G provides accurate diagnosis of non-palpable mammographic abnormalities.
引用
收藏
页码:1063 / 1071
页数:9
相关论文
共 50 条
  • [31] Evaluation of 11-gauge and 9-gauge vacuum-assisted breast biopsy systems in a breast parenchymal model
    Poellinger, Alexander
    Bick, Ulrich
    Freund, Torsten
    Diekmann, Susanne
    Hamm, Bernd
    Diekmann, Felix
    ACADEMIC RADIOLOGY, 2007, 14 (06) : 677 - 684
  • [32] Can galactography-guided stereotactic, 11-gauge, vacuum-assisted breast biopsy of intraductal lesions serve as an alternative to surgical biopsy?
    Reiner, Caecilia S.
    Helbich, Thomas H.
    Rudas, Margaretha
    Ponhold, Lothar
    Riedl, Christopher C.
    Kropf, Nina
    Fuchsjaeger, Michael H.
    EUROPEAN RADIOLOGY, 2009, 19 (12) : 2878 - 2885
  • [33] Can galactography-guided stereotactic, 11-gauge, vacuum-assisted breast biopsy of intraductal lesions serve as an alternative to surgical biopsy?
    Caecilia S. Reiner
    Thomas H. Helbich
    Margaretha Rudas
    Lothar Ponhold
    Christopher C. Riedl
    Nina Kropf
    Michael H. Fuchsjäger
    European Radiology, 2009, 19 : 2878 - 2885
  • [34] Upstaging of atypical ductal hyperplasia after vacuum-assisted 11-gauge stereotactic core needle biopsy
    Winchester, DJ
    Bernstein, JR
    Jeske, JM
    Nicholson, MH
    Hahn, EA
    Goldschmidt, RA
    Watkin, WG
    Sener, SF
    Bilimoria, MB
    Barrera, E
    Winchester, DP
    ARCHIVES OF SURGERY, 2003, 138 (06) : 619 - 622
  • [35] Causes of failure in removing calcium in microcalcification-only lesions using 11-gauge stereotactic vacuum-assisted breast biopsy
    Gumus, Hatice
    Gumus, Metehan
    Devalia, Haresh
    Mills, Philippa
    Fish, David
    Jones, Peter
    Uyar, Asur
    Sever, Ali
    DIAGNOSTIC AND INTERVENTIONAL RADIOLOGY, 2012, 18 (04) : 354 - 359
  • [36] Delayed migration of gel mark ultra clip within 15 days of 11-gauge vacuum-assisted stereotactic breast biopsy
    Parikh, JR
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2005, 185 (01) : 203 - 206
  • [38] Tissue marker clip placement after 11-gauge vacuum-assisted stereotactic breast biopsy: methodological issue on validity and reliability
    Siamak Sabour
    Breast Cancer, 2017, 24 : 730 - 731
  • [39] Atypical ductal hyperplasia diagnosed by 11-gauge, directional, vacuum-assisted breast biopsy: How often is carcinoma found at surgery?
    Jackman, RJ
    Burbank, FH
    Parker, SH
    Evans, WP
    Lechner, MC
    Richardson, TR
    RADIOLOGY, 1997, 205 : 781 - 781
  • [40] Value of stereotactic 11-gauge vacuum-assisted breast biopsy in non-palpable suspicious calcifications: an eight-year single institution experience with 587 patients
    Li, Shiping
    Qu, Feilin
    Yang, Yinlong
    Wang, Lei
    Shen, Juping
    Shao, Zhiming
    GLAND SURGERY, 2020, 9 (05) : 1258 - +