A Technic for Ground Anchor Force Determination from Distributied Strain Using Fiber Optic OFDR Sensor with the Rejection of a Temperature Effect

被引:7
|
作者
Kwon, Il-Bum [1 ]
Kwon, Yong-Seok [1 ]
Seo, Dae-Cheol [1 ]
Yoon, Dong-Jin [1 ]
Kim, Eunho [2 ]
机构
[1] Korea Res Inst Stand & Sci KRISS, Safety Measurement Inst, Daejeon 34113, South Korea
[2] Jeonbuk Natl Univ, Dept Mech Syst Engn, Jeonju 54896, South Korea
来源
APPLIED SCIENCES-BASEL | 2020年 / 10卷 / 23期
基金
芬兰科学院;
关键词
anchor force; ground anchor; bearing plate; distributed strain; OFDR (optical frequency domain reflectometry); temperature effect; RESOLUTION;
D O I
10.3390/app10238437
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Anchor systems are widely used to stabilize soil slope and suppress slope failure. Thus, monitoring conditions of an anchor system is important to prevent disasters due to slope failure. The slope condition can be indirectly monitored by sensing the tensile force applied to the anchor because the slope deformation directly affects the anchor force. Previously, we propose a way to monitor the tensile force of the anchor by measuring the strain field on a bearing plate using a distributed fiber optic sensor (OFDR) and experimentally demonstrate that the anchor force has a large correlation with the strain distribution on the bearing plate. However, it was found that a spatial variation of the strain and thermal strain due to temperature change makes it difficult to get a reliable correlation coefficient. In this study, we newly propose a way to get a reliable correlation coefficient between the anchor force and the strain field on the bearing plate. We install a distributed optical fiber sensor in two concentric circles on the bearing plate and measure circumferential strain distribution. We take average values of the strain field in each circle as representative strain values minimizing the spatial variation and takes a difference of the two strains to exclude the temperature effect. We experimentally demonstrate that the proposed method gives a reliable correlation coefficient between the anchor force and the strain field on the bearing plate. This technique can be applied to various anchor systems to monitor the anchor force and manage the anchor systems safely.
引用
收藏
页码:1 / 10
页数:10
相关论文
共 22 条
  • [21] Real-time seepage health monitoring using spatial autocorrelation of distributed temperature data from fiber optic sensor
    Bekele, Binyam
    Song, Chung
    Abualshar, Basil
    Hunde, Alemtsehay
    JOURNAL OF CIVIL STRUCTURAL HEALTH MONITORING, 2024, : 1101 - 1116
  • [22] High-Temperature Fiber-Optic Sensor for Low-Power Measurement of Wide Dynamic Strain Using Interferometric Techniques and Analog/DSP Methods
    Krisch, Henrik
    Fernandes, Neville
    Gossner, Kai
    Lau, Markus
    Tournillon, Sylvain
    IEEE SENSORS JOURNAL, 2012, 12 (01) : 33 - 38