Maximum likelihood estimation of detector efficiencies in positron emission tomography

被引:0
|
作者
Lee, WH [1 ]
Anderson, JMM [1 ]
Votaw, JR [1 ]
机构
[1] Univ Florida, Dept Elect & Comp Engn, Gainesville, FL 32611 USA
关键词
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In this paper, we introduce a maximum-likelihood (ML) method for estimating detector efficiencies; in positron emission tomography. First, we develop a Poisson model for blank scan data obtained from rotating rod sources. Then, we estimate the detector efficiencies using two expectation-maximization (EM) algorithms that differ in the way the maximization step is solved. As desired, the resulting algorithms have the property that the log-likelihood function is non-decreasing as the iteration number increases. Simulation studies using synthetic data demonstrate that the proposed algorithms outperformed two alternative approaches.
引用
收藏
页码:2049 / 2053
页数:5
相关论文
共 50 条
  • [41] EVALUATION OF A FAST MAXIMUM-LIKELIHOOD METHOD FOR ESTIMATION OF REGION-OF-INTEREST VALUES IN EMISSION TOMOGRAPHY
    CARSON, RE
    BERG, GW
    GREEN, MV
    LARSON, SM
    JOURNAL OF NUCLEAR MEDICINE, 1986, 27 (06) : 895 - 895
  • [42] Positron emission tomography detector performance with different crystal pitches
    Tong L.G.
    Fan Y.M.
    Dong M.
    Zhao L.
    Li Z.X.
    Li Y.G.
    Wang T.Q.
    Yin Y.Z.
    Chen X.M.
    Radiation Detection Technology and Methods, 2017, 1 (2)
  • [43] A NEW LIQUID XENON SCINTILLATION DETECTOR FOR POSITRON EMISSION TOMOGRAPHY
    CHEPEL, VY
    NUCLEAR TRACKS AND RADIATION MEASUREMENTS, 1993, 21 (01): : 47 - 51
  • [44] A BAF2-TMAE DETECTOR FOR POSITRON EMISSION TOMOGRAPHY
    MINE, P
    SANTIARD, JC
    SCIGOCKI, D
    SUFFERT, M
    TAVERNIER, S
    CHARPAK, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (2-3): : 881 - 885
  • [45] A POSITION-SENSITIVE DETECTOR FOR USE IN POSITRON EMISSION TOMOGRAPHY
    KARP, JS
    MANKOFF, DA
    MUEHLLEHNER, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 273 (2-3): : 891 - 897
  • [46] Development of a low cost planar detector for positron emission tomography
    Retiere, F.
    Amaudruz, P. -A.
    Bishop, D.
    Boone, K.
    Lim, C.
    Gumplinger, P.
    Southcott, C.
    Vincent, P.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2012, 695 : 139 - 142
  • [47] Position-sensitive detector for use in positron emission tomography
    Karp, Joel S.
    Mankoff, David A.
    Muehllehner, Gerd
    Nuclear instruments and methods in physics research, 1988, 273 (2-3): : 891 - 897
  • [48] An edge-readout, multilayer detector for positron emission tomography
    Li, Xin
    Ruiz-Gonzalez, Maria
    Furenlid, Lars R.
    MEDICAL PHYSICS, 2018, 45 (06) : 2425 - 2438
  • [49] LOCAL SOLUTIONS OF MAXIMUM LIKELIHOOD ESTIMATION IN QUANTUM STATE TOMOGRAPHY
    Goncalves, Douglas S.
    Gomes-Ruggiero, Marcia A.
    Lavor, Carlile
    Jimenez Farias, Osvaldo
    Souto Ribeiro, P. H.
    QUANTUM INFORMATION & COMPUTATION, 2012, 12 (9-10) : 775 - 790
  • [50] Unified approach to regularized maximum likelihood estimation in computed tomography
    De Pierro, AR
    COMPUTATIONAL, EXPERIMENTAL, AND NUMERICAL METHODS FOR SOLVING ILL-POSED INVERSE IMAGING PROBLEMS: MEDICAL AND NONMEDICAL APPLICATIONS, 1997, 3171 : 218 - 224