Laboratory evaluation of two point-of-care detection systems for early and accurate detection of influenza viruses in the Lao People's Democratic Republic

被引:0
|
作者
Kittikraisak, Wanitchaya [1 ]
Khamphaphongphane, Bouaphanh [2 ]
Xayadeth, Sinakhone [2 ]
Oulay, Virasack Som [2 ]
Khanthamaly, Viengphone [3 ]
Sengvilaipaseuth, Onanong [2 ]
Davis, C. Todd [4 ]
Yang, Genyan [4 ]
Zanders, Natosha [4 ]
Mott, Joshua A. [1 ,4 ]
Xangsayarath, Phonepadith [2 ]
机构
[1] US Ctr Dis Control & Prevent Collaborat, Influenza Program, Thailand Minist Publ Hlth, Nonthaburi, Thailand
[2] Natl Ctr Lab & Epidemiol, Viangchan, Laos
[3] US Ctr Dis Control & Prevent, Viangchan, Laos
[4] US Ctr Dis Control & Prevent, Influenza Div, Atlanta, GA USA
关键词
Point-of-care; Molecular; Influenza; Detection system; Laboratory evaluation;
D O I
10.1016/j.ijid.2020.12.059
中图分类号
R51 [传染病];
学科分类号
100401 ;
摘要
Background: We evaluated molecular-based point-of-care influenza virus detection systems in a laboratory prior to a field evaluation of on-site specimen testing. Methods: The performance characteristics of 1) insulated isothermal polymerase chain reaction (PCR) on a POCKIT (TM) device and 2) real-time reverse transcription-PCR (rRT-PCR) on a MyGo Mini (TM) device were evaluated using human clinical specimens, beta-propiolactone-inactivated influenza viruses, and RNA controls. The rRT-PCR carried out on a CXF-96 (TM) real-time detection system was used as a gold standard for comparison. Results: Both systems demonstrated 100% sensitivity and specificity and test results were in 100% agreement with the gold standard. POCKIT (TM) only correctly identified influenza A (M gene) in clinical specimens due to the unavailability of typing and subtyping reagents for human influenza viruses, while MyGo Mini (TM) had either a one log higher or the same sensitivity in detecting influenza viruses in clinical specimens compared to the gold standard. For inactivated viruses and/or viral RNA, the analytic sensitivity of POCKIT (TM) was shown to be comparable to, or more sensitive, than the gold standard. The analytic sensitivity of MyGo Mini (TM) had mixed results depending on the types and subtypes of influenza viruses. Conclusions: The performance of the two systems in a laboratory is promising and supports further evaluation in field settings. Published by Elsevier Ltd on behalf of International Society for Infectious Diseases.
引用
收藏
页码:214 / 221
页数:8
相关论文
共 41 条
  • [31] Clinical evaluation of a novel digital microfluidic based point-of-care test platform for detection of SARS-Cov-2 and influenza A/B
    Huang, Huitao
    Long, Dongling
    Lin, Yixiong
    Dong, Cheng
    Huang, Wenyan
    Zhang, Mengjuan
    Wan, Liang
    Gou, Hongna
    Chen, Tianlan
    Li, Fei
    JOURNAL OF CLINICAL VIROLOGY, 2024, 173
  • [32] Accurate PCR Detection of Influenza A/B and RSV Using the Cepheid Xpert Flu plus RSV Xpress Assay in Point-of-Care Settings: Comparison to Prodesse ProFlu
    Gibson, J. S.
    Rodriguez, C.
    Bruce, E.
    McGann, K.
    Gunsolue, B.
    May, L.
    Harnett, G.
    Mayer, M.
    Gaydos, C.
    Barnes, M.
    Cohen, D.
    Kline, J.
    Liang, S.
    House, S.
    Rafique, Z.
    Cohen, J.
    Robak, N.
    Phillips, D.
    JOURNAL OF MOLECULAR DIAGNOSTICS, 2016, 18 (06): : 980 - +
  • [33] Multisite Laboratory Evaluation of a Dual Human Immunodeficiency Virus (HIV)/Syphilis Point-of-Care Rapid Test for Simultaneous Detection of HIV and Syphilis Infection
    Bristow, Claire C.
    Adu-Sarkodie, Yaw
    Ondondo, Raphael O.
    Bukusi, Elizabeth Anne
    Dagnra, Claver Anoumou
    Oo, Khin Yi
    Pe, Eh Htoo
    Khamsay, Chanthavysouk
    Houng, Le Thi
    Campuzano, Roberto Vazquez
    Estes, Jason
    Klausner, Jeffrey D.
    OPEN FORUM INFECTIOUS DISEASES, 2014, 1 (01):
  • [34] Point-of-Care Test for Detection of Urogenital Chlamydia in Women Shows Low Sensitivity. A Performance Evaluation Study in Two Clinics in Suriname
    van der Helm, Jannie J.
    Sabajo, Leslie O. A.
    Grunberg, Antoon W.
    Morre, Servaas A.
    Speksnijder, Arjen G. C. L.
    de Vries, Henry J. C.
    PLOS ONE, 2012, 7 (02):
  • [35] Detection of active hepatitis C by two-step point-of-care based strategy and linkage to care among excluded people using a mobile unit in Madrid, Spain
    Ryan, Pablo
    Valencia, Jorge
    Cuevas, Guillermo
    Torres, Juan
    Troya, Jesus
    Lazarus, Jeffrey
    Jose Munoz-Gomez, Maria
    Vazquez-Moron, Sonia
    Resino-Garcia, Salvador
    JOURNAL OF HEPATOLOGY, 2021, 75 : S771 - S771
  • [36] Diagnostic accuracy of a rapid RT-PCR assay for point-of-care detection of influenza A/B virus at emergency department admission: A prospective evaluation during the 2017/2018 influenza season
    Maignan, Maxime
    Viglino, Damien
    Hablot, Maud
    Masson, Nicolas Termoz
    Lebeugle, Anne
    Muret, Roselyne Collomb
    Makele, Prudence Mabiala
    Guglielmetti, Valerie
    Morand, Patrice
    Lupo, Julien
    Forget, Virginie
    Landelle, Caroline
    Larrat, Sylvie
    PLOS ONE, 2019, 14 (05):
  • [37] Detection of pyrethroid resistance mutations and intron variants in the voltage-gated sodium channel of Aedes (Stegomyia) aegypti and Aedes (Stegomyia) albopictus mosquitoes from Lao People's Democratic Republic
    Marcombe, Sebastien
    Shimell, Katherine
    Savage, Rachel
    Howlett, Edward
    Luangamath, Phonesavanh
    Nilaxay, Somphat
    Vungkyly, Vacky
    Baby, Anne
    King, Mathew
    Clarke, Josie
    Jeffries, Chloe
    Jojo, Josna
    Lacey, Emily
    Bhatty, Farris
    Mabika, Dadirayi
    Dela Cruz, Andrea
    Fisher, Cerys
    Mbadu, Milca
    Despiniadis, Iasonas
    Brey, Paul T.
    Thammavong, Phoutmany
    Jones, Andrew K.
    MEDICAL AND VETERINARY ENTOMOLOGY, 2022, 36 (04) : 424 - 434
  • [38] Clinical evaluation of rapid point-of-care testing for detection of novel influenza A (H1N1) virus in a population-based study in Spain
    Ortiz de la Tabla, V.
    Antequera, P.
    Masia, M.
    Ros, P.
    Martin, C.
    Gazquez, G.
    Bunuel, F.
    Sanchez, V.
    Robledano, C.
    Gutierrez, F.
    CLINICAL MICROBIOLOGY AND INFECTION, 2010, 16 (09) : 1358 - 1361
  • [39] Evaluation of the Xpert Flu A Panel nucleic acid amplification-based point-of-care test for influenza A virus detection and pandemic H1 subtyping
    Jenny, Shireen L.
    Hu, Yaobi
    Overduin, Pieter
    Meijer, Adam
    JOURNAL OF CLINICAL VIROLOGY, 2010, 49 (02) : 85 - 89
  • [40] Efficacy of careHPV™ human papillomavirus screening versus conventional cytology tests for the detection of precancerous and cancerous cervical lesions among women living with HIV-1 in Lao People's Democratic Republic
    Paboriboune, Phimpha
    Phongsavan, Keokedthong
    Arounlangsy, Phetsamone
    Flaissier, Bruno
    Aphayarath, Oukham
    Phimmasone, Prasit
    Banchongphanith, Ketmala
    Xayaovong, Mixi
    Jourdain, Gonzague
    Schott, Anne-Marie
    Saadatian-Elahi, Mitra
    Magaud, Laurent
    Klich, Amna
    Ngo-Giang-Huong, Nicole
    Heard, Isabelle
    Rabilloud, Muriel
    Picot, Valentina Sanchez
    Longuet, Christophe
    CANCER MEDICINE, 2022, : 1984 - 1994