Quantification of an Amorphous Phase in a Cement Samples by Powder X-ray Diffractometry/Rietveld Refinement with Reference Intensity Ratio

被引:2
|
作者
Ohbuchi, Atsushi [1 ]
Kuzumaki, Takahiro [1 ]
Nakamura, Toshihiro [1 ,2 ]
机构
[1] Rigaku Corp, Xray Instrumental Div, 3-9-12 Matsubara Cho, Akishima, Tokyo 1968666, Japan
[2] Meiji Univ, Dept Appl Chem, Tama Ku, 1-1-1 Higashimita, Kawasaki, Kanagawa 2148571, Japan
关键词
X-ray difftactometry; Rietveld refinement; RIR method; amorphous phase; cement material; QUANTITATIVE INTERPRETATION; DIFFRACTION PATTERNS; MIXTURES;
D O I
10.2116/bunsekikagaku.68.609
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Quantitative analysis was performed by X-ray diffraction/Rietveld refinement with the Reference Intensity Ratio (RIR) method serving as the basis for determining the halo (background) intensity characteristic of the amorphous content. Although quantification by Rietveld analysis based on RIR is a standard-less method, there are few examples of this application in the literature. Since no RIR value exists for the amorphous phase, it was necessary to empirically determine the amorphous RIR value by gravimetrically preparing a set of simulated samples from blast-furnace slag and other reagents. The RIR value of the amorphous phase was determined to be 3.60, as calculated from the minimum root-meansquare error (RMSE) between known and analyzed values of crystalline and amorphous phases by a Rietveld refinement with various RIR values. Subsequently, this RIR value was applied to analyze the contents of amorphous phases in two commercial cement sample analytical results of the amorphous and crystalline phases in the cement samples by the RIR method were in good agreement with analytical results by the internal standard method (using silicon). It was thus demonstrated that Rietveld refinement, using the RIR value as the basis for the halo intensity, was an effective method for the quantitative analysis of the amorphous phase in cement.
引用
收藏
页码:609 / 614
页数:6
相关论文
共 50 条
  • [21] Rietveld refinement of KLaTiO4 from X-ray powder data
    Zhu, Bai-Chuan
    Tang, Kai-Bin
    [J]. ACTA CRYSTALLOGRAPHICA SECTION E-STRUCTURE REPORTS ONLINE, 2011, 67 : I26 - U65
  • [22] Local structure in amorphous phases of piroxicam from powder X-ray diffractometry
    Sheth, AR
    Bates, S
    Muller, FX
    Grant, DJW
    [J]. CRYSTAL GROWTH & DESIGN, 2005, 5 (02) : 571 - 578
  • [23] Simultaneous Quantification of an Enantiomer and the Racemic Compound of Ibuprofen by X-ray Powder Diffractometry
    Neelima V. Phadnis
    Raj Suryanarayanan
    [J]. Pharmaceutical Research, 1997, 14 : 1176 - 1180
  • [24] Simultaneous quantification of an enantiomer and the racemic compound of ibuprofen by X-ray powder diffractometry
    Phadnis, NV
    Suryanarayanan, R
    [J]. PHARMACEUTICAL RESEARCH, 1997, 14 (09) : 1176 - 1180
  • [25] X-ray powder diffraction data and Rietveld refinement for rare earth compound ErCoSn
    Wu, Shiwei
    Zhang, Liping
    Zeng, Lingmin
    Yan, Jialin
    He, Wei
    [J]. Zhongguo Youse Jinshu Xuebao/Chinese Journal of Nonferrous Metals, 9 (SUPPL. 1): : 242 - 245
  • [26] RIETVELD REFINEMENT OF POWDER X-RAY DIFFRACTION OF NANOCRYSTALLINE NOBLE METALS - TUNGSTEN TRIOXIDE
    Indrea, Emil
    Bica, Ecaterina
    Popovici, Elisabeth-Jeanne
    Suciu, Ramona-Crina
    Rosu, Marcela Corina
    Silipas, Teofil-Danut
    [J]. REVUE ROUMAINE DE CHIMIE, 2011, 56 (06) : 589 - +
  • [27] The structure of CeAlO3 by Rietveld refinement of X-ray powder diffraction data
    Fu, WT
    IJdo, DJW
    [J]. JOURNAL OF SOLID STATE CHEMISTRY, 2004, 177 (09) : 2973 - 2976
  • [28] 'Pink'-beam X-ray powder diffraction profile and its use in Rietveld refinement
    Von Dreele, Robert B.
    Clarke, Samantha M.
    Walsh, James P. S.
    [J]. JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2021, 54 (54) : 3 - 6
  • [29] Quantification of amorphous siliceous fly ash in hydrated blended cement pastes by X-ray powder diffraction
    Li, Xuerun
    Snellings, Ruben
    Scrivener, Karen L.
    [J]. JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2019, 52 : 1358 - 1370
  • [30] Precision and detection limit of quality test for amorphous drug in powder X-ray diffractometry
    Kitahara, S
    Ishizuka, T
    Kikkoji, T
    Matsuda, R
    Hayashi, Y
    [J]. INTERNATIONAL JOURNAL OF PHARMACEUTICS, 2004, 283 (1-2) : 63 - 69