Respiratory protection against Mycobacterium tuberculosis:: Quantitative fit test outcomes for five Type N95 filtering-facepiece respirators

被引:67
|
作者
Lee, K
Slavcev, A
Nicas, M
机构
[1] Univ Calif Davis, Dept Epidemiol & Prevent Med, Davis, CA 95616 USA
[2] Calif Dept Hlth Serv, Occupat Hlth Branch, Oakland, CA USA
[3] Univ Calif Berkeley, Sch Publ Hlth, Ctr Occupat & Environm Hlth, Berkeley, CA 94720 USA
基金
美国国家科学基金会;
关键词
quantitative fit test; respirator selection; respiratory protection; Type N95 respirator;
D O I
10.1080/15459620490250026
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
In preparing to fit test a large workforce, a respirator program manager needs to initially choose respirators that will fit the greatest proportion of employees and achieve the best fits. This article discusses our strategy in selecting respirators from the initial array of seven NIOSH-certified Type N95 filtering-facepiece devices for a respiratory protection program against Mycobacterium tuberculosis (M. tb) aerosol. The seven respirators were screened based on manufacturer-provided fit test data, comfort, and cost. From these 7 devices, 5 were chosen for quantitative fit testing on 40 subjects who were a convenience sample from a cohort of approximately 30,000 workers scheduled to undergo fit testing. Across the five brands, medium/regular-size respirators fit from 8% to 95% of the subjects: providing another size of the same brand improved the pass rates slightly. Gender was not found to significantly affect fit test pass rates for any respirator brand. Among test panel members, an Aearo Corporation respirator (TC 84A-2630) and a 3M Company respirator (TC 84A-0006) provided the highest overall pass rates of 98% and 90%, respectively. We selected these two brands for fit testing in the larger worker cohort. To date, these two respirators have provided overall pass rates of 98% (1793/1830) and 88% (50/57), respectively, which are similar to the test panel results. Among 1850 individuals who have been fit tested, 1843 (99.6%) have been successfully fitted with one or the other brand. In a separate analysis, we used the test panel pass rates to estimate the reduction in M. tb infection risk afforded by the medium/regular-size of five filtering-facepiece respirators. We posed a low-exposure versus a high-exposure scenario for health care workers and assumed that respirators could be assigned without conducting fit testing, as proposed by many hospital infection control practitioners. Among those who would pass versus fail the fit test, we assumed an average respirator penetration (primarily due to faceseal leakage) of .04 and 0.3, respectively. The respirator with the highest overall pass rate (95%) reduced M. tb infection risk by 95%, while the respirator with the lowest pass rate (8%) reduced M. tb infection risk by only 70%. To promote the marketing of respirators that will successfully fit the highest proportion of wearers, and to increase protection for workers who might use respirators without the benefit of being tested, we recommend that fit testing be part of the NIOSH certification process for negative-pressure air-purifying respirators with tightly fitting facepieces. At a minimum, we recommend that respirator manufacturers generate and provide pass rate data to assist in selecting candidate respirators. In any event, program managers can initially select candidate respirators by comparing quantitative fit tests for a representative sample of their employee population.
引用
收藏
页码:22 / 28
页数:7
相关论文
共 35 条
  • [21] Comparing mask fit and usability of traditional and nanofibre N95 filtering facepiece respirators before and after nursing procedures
    Suen, L. K. P.
    Guo, Y. P.
    Ho, S. S. K.
    Au-Yeung, C. H.
    Lam, S. C.
    JOURNAL OF HOSPITAL INFECTION, 2020, 104 (03) : 336 - 343
  • [22] Implementing fit testing for N95 filtering facepiece respirators: Practical information from a large cohort of hospital workers
    McMahon, Elizabeth
    Wada, Koji
    Dufresne, Andre
    AMERICAN JOURNAL OF INFECTION CONTROL, 2008, 36 (04) : 298 - 300
  • [23] Laboratory Faceseal Leakage Evaluation of N95 Filtering Facepiece Respirators Against Nanoparticles and "All Size" Particles
    Zhuang, Ziqing
    Bergman, Michael S.
    Eimer, Benjamin C.
    Shaffer, Ronald E.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2013, 10 (09) : 496 - 504
  • [24] Physiologic and fit factor profiles of N95 and P100 filtering facepiece respirators for use in hot, humid environments
    Kim, Jung-Hyun
    Wu, Tianzhou
    Powell, Jeffrey B.
    Roberge, Raymond J.
    AMERICAN JOURNAL OF INFECTION CONTROL, 2016, 44 (02) : 194 - 198
  • [25] Fit Test for N95 Filtering Facepiece Respirators and KF94 Masks for Healthcare Workers: a Prospective Single-center Simulation Study
    Park, Jin Ju
    Seo, Yu Bin
    Lee, Jacob
    JOURNAL OF KOREAN MEDICAL SCIENCE, 2021, 36 (21)
  • [26] P2/N95 filtering facepiece respirators: Results of a large-scale quantitative mask fit testing program in Australian health care workers
    Milosevic, Maxim
    Biswas, Raaj Kishore
    Innes, Lesley
    Ng, Martin
    Darendeliler, Ali Mehmet
    Wong, Alice
    Denney-Wilson, Elizabeth
    AMERICAN JOURNAL OF INFECTION CONTROL, 2022, 50 (05) : 509 - 515
  • [27] Evaluation of the Filtration Performance of NIOSH-Approved N95 Filtering Facepiece Respirators by Photometric and Number-Based Test Methods
    Rengasamy, Samy
    Miller, Adam
    Eimer, Benjamin C.
    JOURNAL OF OCCUPATIONAL AND ENVIRONMENTAL HYGIENE, 2011, 8 (01) : 23 - 30
  • [28] Fit-failure rate associated with simulated reuse and extended use of N95 respirators assessed by a quantitative fit test
    Jung, Jiwon
    Kim, Jiyun
    Yang, Hyejin
    Lim, Young-Ju
    Kwak, Sun-Hee
    Hong, Min Jee
    Kim, Eun Ok
    Kim, Sung-Han
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2021, 42 (11): : 1313 - 1317
  • [29] N95 respirators: quantitative fit test pass rates and usability and comfort assessment by health care workers
    Ng, Irene
    Kave, Benjamin
    Begg, Fiona
    Bodas, Charles R.
    Segal, Reny
    Williams, Daryl
    MEDICAL JOURNAL OF AUSTRALIA, 2022, 217 (02) : 88 - 93
  • [30] Impact on quantitative fit-test results after application of prophylactic hydrocolloid dressing under N95 respirators
    Ng, Irene
    Kave, Benjamin
    Begg, Fiona
    Sage, Sarah
    Segal, Reny
    Williams, Daryl L.
    INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2022, 43 (08): : 993 - 996