Comparison of dosimetric effects of MLC positional errors on VMAT and IMRT plans for SBRT radiotherapy in non-small cell lung cancer

被引:4
|
作者
Deng, Jia [1 ,2 ]
Huang, Yun [3 ]
Wu, Xiangyang [1 ]
Hong, Ye [4 ]
Zhao, Yaolin [2 ]
机构
[1] Shaanxi Prov Canc Hosp, Dept Radiat Oncol, Xian, Shaanxi, Peoples R China
[2] Xi An Jiao Tong Univ, Sch Nucl Sci & Technol, Xian, Shaanxi, Peoples R China
[3] Xianyang Cent Hosp, Dept Radiat Oncol, Xian, Shaanxi, Peoples R China
[4] Shaanxi Prov Canc Hosp, Ctr Digest Endoscopy, Xian, Shaanxi, Peoples R China
来源
PLOS ONE | 2022年 / 17卷 / 12期
关键词
BODY RADIATION-THERAPY; CLINICAL-SIGNIFICANCE; DELIVERY;
D O I
10.1371/journal.pone.0278422
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
The positional accuracy of multi-leaf collimators (MLC) is important in stereotactic body radiotherapy (SBRT). The aim of this study was to investigate the impact between MLC positional error and dosimetry of volume intensity modulated (VMAT) and general intensity modulated (IMRT) plans for non-small cell lung cancer (NSCLC). Fifteen patients with NSCLC were selected to design the 360 SBRT-VMAT plans and the 360 SBRT-IMRT error plans. The DICOM files for these treatment plans were imported into a proprietary computer program that introduced delivery errors. Random and systematic MLC position (0.1, 0.2, 0.5, 1.0, 1.5, and 2.0 mm) errors were introduced. The systematic errors were shift errors (caused by gravity), opening errors, and closing errors. The CI, GI, d(2cm) and generalized equivalent uniform dose (gEUD) were calculated for the original plan and all treatment plans, accounting for the errors. Dose sensitivity was calculated using linear regression for MLC position errors. The random MLC errors were relatively insignificant. MLC shift, opening, and closing errors had a significant effect on the dose distribution of the SBRT plan. VMAT was more significant than IMRT. To ensure that the gEUD variation of PTV is controlled within 2%, the shift error, opening error, and closing error of IMRT should be less than 2.4 mm, 1.15 mm, and 0.97 mm, respectively. For VMAT, the shift error, opening error, and closing error should be less than 0.95 mm, 0.32 mm, and 0.38 mm, respectively. The dose sensitivity results obtained in this study can be used as a guide for patient-based quality assurance efforts. The position error of the MLC system had a significant impact on the gEUD of the SBRT technology. The MLC systematic error has a greater dosimetric impact on the VMAT plan than on the IMRT plan for SBRT, which should be carefully monitored.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Dosimetric evaluation of different IMRT treatment plans for non-small cell lung cancer
    Shenglin, M.
    Yaping, X.
    Jian, W.
    Pu, L.
    Xiaoyun, D.
    Xiaojiang, S.
    Yongling, J.
    Hao, J.
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2010, 28 (15)
  • [2] Dosimetric Comparison of Different Algorithms in SBRT Planning for Non-Small Cell Lung Cancer
    Zhang, J.
    Shen, J.
    Jiang, D.
    Yu, H.
    Liu, H.
    Xie, C.
    Dai, J.
    [J]. MEDICAL PHYSICS, 2019, 46 (06) : E543 - E544
  • [3] A dosimetric retrospective planning study comparing volumetric arc therapy (VMAT) and stereotactic body radiotherapy (SBRT) treatment plans for non-small cell lung cancer (NSCLC)
    Peter, Maungwe
    Crispen, Chamunyonga
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2015, 14 (03) : 260 - 267
  • [4] Dosimetric evaluation of VMAT for palliative radiotherapy for non-small cell lung carcinoma
    Iqbal, Muhammad Shahid
    Richmond, Neil
    Ogilvie, Audrey
    Pilling, Karen
    Willis, Nicholas
    Byrne, John
    Walker, Christoph Er
    West, Nicholas
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1091):
  • [5] A dosimetric comparison of radical radiotherapy techniques in non-small cell lung cancer
    Gleeson, I.
    Jayaprakash, K. Thippu
    [J]. LUNG CANCER, 2020, 139 : S37 - S38
  • [6] A dosimetric evaluation of VMAT for the treatment of non-small cell lung cancer
    Merrow, Caitlin E.
    Wang, Iris Z.
    Podgorsak, Matthew B.
    [J]. JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2013, 14 (01): : 228 - 238
  • [7] Dosimetric Discrepancies due to Positional Errors in MLC Movement During Stereotactic Lung VMAT
    Karan, T.
    Kim, S.
    Abbas, A.
    Moseley, D. J.
    Taremi, M. M.
    Yeung, I.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S190 - S190
  • [8] A Hybrid IMRT/VMAT technique for the treatment of non-small cell lung cancer
    Zhao, N.
    Yang, R. J.
    Wang, J. J.
    Zhang, X. L.
    Jiang, W. J.
    Li, J. N.
    Jiang, P.
    Meng, N.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S857 - S857
  • [9] Comparison of Dosimetric Parameters and Outcome in Non-Small Cell Lung Cancer Patients Having 3D Conformal or VMAT Plans
    Satar, N. Abdul
    Lynch, S.
    Wells, P.
    Bowles, S.
    Yip, K.
    Conibear, J.
    [J]. JOURNAL OF THORACIC ONCOLOGY, 2017, 12 (11) : S2038 - S2038
  • [10] Comparison of VMAT Vs Arc Treatment Plans for Patients Undergoing SBRT of Early-Stage Non-Small Cell Lung Cancer (NSCLC)
    Neicu, T.
    Chan, P.
    Valakh, V.
    Bizhan, M.
    Miyamoto, C.
    Li, S.
    [J]. MEDICAL PHYSICS, 2012, 39 (06) : 3855 - 3855