A dosimetric evaluation of VMAT for the treatment of non-small cell lung cancer

被引:31
|
作者
Merrow, Caitlin E. [1 ]
Wang, Iris Z.
Podgorsak, Matthew B.
机构
[1] Roswell Pk Canc Inst, Dept Radiat Med, Buffalo, NY 14263 USA
来源
关键词
volumetric-modulated arc therapy (VMAT); stereotactic body radiation therapy (SBRT); three-dimensional conformal radiation therapy (3D CRT); non-small cell lung cancer (NSCLC); VOLUMETRIC MODULATED ARC; BODY RADIATION-THERAPY; RADIOTHERAPY; IMRT; TUMORS;
D O I
10.1120/jacmp.v14i1.4110
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to demonstrate the dosimetric potential of volumetric-modulated arc therapy (VMAT) for the treatment of patients with medically inoperable stage I/II non-small cell lung cancer (NSCLC) with stereotactic body radiation therapy (SBRT). Fourteen patients treated with 3D CRT with varying tumor locations, tumor sizes, and dose fractionation schemes were chosen for study. The prescription doses were 48 Gy in 4 fractions, 52.5 Gy in 5 fractions, 57.5 Gy in 5 fractions, and 60 Gy in 3 fractions for 2, 5, 1, and 6 patients, respectively. VMAT treatment plans with a mix of two to three full and partial noncoplanar arcs with 5 degrees-25 degrees separations were retrospectively generated using Eclipse version 10.0. The 3D CRT and VMAT plans were then evaluated by comparing their target dose, critical structure dose, high dose spillage, and low dose spillage as defined according to RTOG 0813 and RTOG 0236 protocols. In the most dosimetrically improved case, VMAT was able to decrease the dose from 17.35 Gy to 1.54 Gy to the heart. The D-2cm decreased in 11 of 14 cases when using VMAT. The three that worsened were still within the acceptance criteria. Of the 14 3D CRT plans, seven had a D-2cm minor deviation, while only one of the 14 VMAT plans had a D-2cm minor deviation. The R-50% improved in 13 of the 14 VMAT cases. The one case that worsened was still within the acceptance criteria of the RTOG protocol. Of the 14 3D CRT plans, seven had an R-50% deviation. Only one of the 14 VMAT plans had an R50% deviation, but it was still improved compared to the 3D CRT plan. In this cohort of patients, no evident dosimetric compromises resulted from planning SBRT treatments with VMAT relative to the 3D CRT treatment plans actually used in their treatment.
引用
收藏
页码:228 / 238
页数:11
相关论文
共 50 条
  • [1] Dosimetric evaluation of VMAT for palliative radiotherapy for non-small cell lung carcinoma
    Iqbal, Muhammad Shahid
    Richmond, Neil
    Ogilvie, Audrey
    Pilling, Karen
    Willis, Nicholas
    Byrne, John
    Walker, Christoph Er
    West, Nicholas
    [J]. BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1091):
  • [2] Are there any dosimetric advantages in using VMAT for treatment of locally advanced non-small cell lung cancer?
    Rousseau, D.
    Autret, D.
    Krhili, S.
    Yossi, S.
    Dupas, A.
    Edouard, M.
    Mahe, M. -A.
    Giraud, P.
    Le Pechoux, C.
    Cellier, P.
    Denis, F.
    Paumier, A.
    [J]. CANCER RADIOTHERAPIE, 2012, 16 (07): : 619 - 626
  • [3] Dosimetric evaluation of VMAT treatment plans for patients with stage IIB or III non-small cell lung carcinoma
    Shaaer, Amani
    Darko, Johnson
    Gopaul, Darin
    Osei, Ernest
    [J]. MEDICAL PHYSICS, 2022, 49 (08) : 5684 - 5684
  • [4] Dosimetric evaluation of VMAT treatment plans for patients with stage IIB or III non-small cell lung carcinomas
    Shaaer, Amani
    Osei, Ernest
    Darko, Johnson
    Gopaul, Darin
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2023, 22
  • [5] Dosimetric evaluation of different IMRT treatment plans for non-small cell lung cancer
    Shenglin, M.
    Yaping, X.
    Jian, W.
    Pu, L.
    Xiaoyun, D.
    Xiaojiang, S.
    Yongling, J.
    Hao, J.
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2010, 28 (15)
  • [6] A Hybrid IMRT/VMAT technique for the treatment of non-small cell lung cancer
    Zhao, N.
    Yang, R. J.
    Wang, J. J.
    Zhang, X. L.
    Jiang, W. J.
    Li, J. N.
    Jiang, P.
    Meng, N.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S857 - S857
  • [7] On the possible benefits of a hybrid VMAT technique in the treatment of non-small cell lung cancer
    Agapito, John
    [J]. MEDICAL DOSIMETRY, 2013, 38 (04) : 460 - 466
  • [8] A Novel Integrated VMAT/IMRT Technique for the Treatment of Non-Small Cell Lung Cancer
    Zhao, N.
    Yang, R.
    Wang, J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S54 - S55
  • [9] A Novel Integrated VMAT/IMRT Technique For the Treatment of Non-Small Cell Lung Cancer
    Zhao, N.
    Yang, R.
    Wang, J.
    [J]. MEDICAL PHYSICS, 2014, 41 (06) : 367 - 367
  • [10] A Novel Integrated VMAT/IMRT Technique for the Treatment of Non-Small Cell Lung Cancer
    Zhao, N.
    Yang, R.
    Wang, J.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2014, 90 : S937 - S937