Blood flow characteristics in the ascending aorta after TAVI compared to surgical aortic valve replacement

被引:36
|
作者
Trauzeddel, Ralf Felix [1 ,2 ]
Loebe, Ulrike [3 ]
Barker, Alex J. [4 ,5 ]
Gelsinger, Carmen [3 ]
Butter, Christian [3 ]
Markl, Michael [4 ,5 ]
Schulz-Menger, Jeanette [1 ,2 ]
von Knobelsdorff-Brenkenhoff, Florian [1 ,2 ]
机构
[1] Charite, Working Grp Cardiovasc Magnet Resonance, Expt & Clin Res Ctr, Lindenberger Weg 80, D-13125 Berlin, Germany
[2] HELIOS Klinikum Berlin Buch, Dept Cardiol & Nephrol, Berlin, Germany
[3] Immanuel Klinikum Bernau, Dept Cardiol, Heart Ctr Brandenburg, Bernau, Germany
[4] Northwestern Univ, Dept Radiol, Feinberg Sch Med, Chicago, IL USA
[5] Northwestern Univ, Dept Biomed Engn, McCormick Sch Engn, Chicago, IL 60611 USA
来源
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING | 2016年 / 32卷 / 03期
基金
美国国家卫生研究院;
关键词
Magnetic resonance imaging; Aorta; Aortic valve replacement; Shear stress; Transcatheter aortic valve implantation; 4D-flow; WALL SHEAR-STRESS; MAGNETIC-RESONANCE; TRANSCATHETER; MRI; IMPLANTATION; STENOSIS; DISEASE; HEMODYNAMICS; ANEURYSMS; PATTERNS;
D O I
10.1007/s10554-015-0792-x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Ascending aortic blood flow characteristics are altered after aortic valve surgery, but the effect of transcatheter aortic valve implantation (TAVI) is unknown. Abnormal flow may be associated with aortic and cardiac remodeling. We analyzed blood flow characteristics in the ascending aorta after TAVI in comparison to conventional stented aortic bioprostheses (AVR) and healthy subjects using time-resolved three-dimensional flow-sensitive cardiovascular magnetic resonance imaging (4D-flow MRI). Seventeen patients with TAVI (Edwards Sapien XT), 12 with AVR and 9 healthy controls underwent 4D-flow MRI of the ascending aorta. Target parameters were: severity of vortical and helical flow pattern (semiquantitative grading from 0 = none to 3 = severe) and the local distribution of systolic wall shear stress (WSSsystole). AVR revealed significantly more extensive vortical and helical flow pattern than TAVI (p = 0.042 and p = 0.002) and controls (p < 0.001 and p = 0.001). TAVI showed significantly more extensive vortical flow than controls (p < 0.001). Both TAVI and AVR revealed marked blood flow eccentricity (64.7 and 66.7 %, respectively), whereas controls showed central blood flow (88.9 %). TAVI and AVR exhibited an asymmetric distribution of WSSsystole in the mid-ascending aorta with local maxima at the right anterior aortic wall and local minima at the left posterior wall. In contrast, controls showed a symmetric distribution of WSSsystole along the aortic circumference. Blood flow was significantly altered in the ascending aorta after TAVI and AVR. Changes were similar regarding WSSsystole distribution, while TAVI resulted in less helical and vortical blood flow.
引用
收藏
页码:461 / 467
页数:7
相关论文
共 50 条
  • [41] SUCCESSFUL REPLACEMENT OF ENTIRE ASCENDING AORTA + AORTIC VALVE
    WHEAT, MW
    BARTLEY, TD
    WILSON, JR
    JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1964, 188 (08): : 717 - &
  • [42] Clinical outcomes after separate and composite replacement of the aortic valve and ascending aorta
    Sioris, T
    David, TE
    Ivanov, J
    Armstrong, S
    Feindel, CM
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2004, 128 (02): : 260 - 265
  • [43] AORTIC VALVE REPLACEMENT AFTER PREVIOUS TAVI
    Titov, D. A.
    Sorkomov, M. N.
    Pursanova, D. M.
    Fedoseykina, M. I.
    Babenko, S. I.
    Muratov, R. M.
    VESTNIK TRANSPLANTOLOGII I ISKUSSTVENNYH ORGANOV, 2023, 25 (03): : 129 - 138
  • [44] A Case of Ascending Aortic Replacement and Aortic Valve Replacement in a Patient with Giant Pseudoaneurysm of the Ascending Aorta due to Prosthetic Valve Endocarditis after Transcatheter Aortic Valve Replacement Using Evolut PRO
    Tomita, Satoru
    Maeda, Koichi
    Shimamura, Kazuo
    Yamashita, Kizuku
    Kawamura, Ai
    Yoshioka, Daisuke
    Miyagawa, Shigeru
    ANNALS OF THORACIC AND CARDIOVASCULAR SURGERY, 2024, 30 (01)
  • [45] Surgical aortic valve replacement for stenosis of TAVI device
    Sooknunden, M.
    Radermecker, M. A.
    Defraigne, J. O.
    Tchana-Sato, Vincent
    ACTA CHIRURGICA BELGICA, 2017, 117 (06) : 401 - 403
  • [46] Replacement of calcified ascending aorta in patients undergoing aortic valve replacement
    Chang, Hyoung Woo
    Jeong, Dong Seop
    Cho, Yang Hyun
    Sung, Kiick
    Kim, Wook-Sung
    Lee, Young Tak
    Park, Pyo Won
    JOURNAL OF THORACIC DISEASE, 2017, 9 (11) : 4424 - 4433
  • [47] Surgical approach to ascending aorta in bicuspid aortic valve
    Kuralay, E
    Özal, E
    Cingöz, F
    Ceylan, S
    Tatar, H
    JOURNAL OF CARDIAC SURGERY, 2003, 18 (02) : 173 - 180
  • [48] Is cardiac rehabilitation (CR) safe and useful in octogenarians after transcatheter aortic valve implantation (TAVI) compared to surgical aortic valve replacement (sAVR) for aortic stenosis?
    Genta, F. Tarro
    Eleuteri, E.
    Bertolin, F.
    Bouslenko, Z.
    Taglieri, C.
    Tidu, M.
    Giannuzzi, P.
    EUROPEAN HEART JOURNAL, 2015, 36 : 515 - 515
  • [49] Isolated surgical aortic valve replacement in octogenarians before and after the introduction of transcatheter aortic valve implantation (TAVI)
    Khounlaboud, M.
    Donal, E.
    Auffret, V.
    Ingels, A.
    Flecher, E.
    Verhoye, J. P.
    Mabo, P.
    Le Breton, H.
    Leguerrier, A.
    EUROPEAN HEART JOURNAL, 2014, 35 : 686 - 686
  • [50] A SAFER TECHNIQUE FOR REPLACEMENT OF ENTIRE ASCENDING AORTA AND AORTIC VALVE
    EDWARDS, WS
    KERR, AR
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1970, 59 (06): : 837 - &