Experimental study on the thermal behaviour of fire exposed slim-floor beams

被引:0
|
作者
Albero, V [1 ]
Espinos, A. [1 ]
Serra, E. [1 ]
Romero, M. L. [1 ]
Hospitaler, A. [1 ]
机构
[1] Univ Politecn Valencia, ICITECH, Valencia, Spain
关键词
Composite steel-concrete beams; fire resistance; slim-floors; thermal behaviour;
D O I
10.4995/ASCCS2018.2018.8288
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Steel-concrete composite beams embedded in floors ( slim-floors) offer various advantages such as the floor thickness reduction or the ease of installation of under-floor technical equipment. However, this typology presents important differences in terms of thermal behaviour, as compared to other composite beams, when exposed to elevated temperatures. These differences are due to their special configuration, being totally contained within the concrete floor depth. Moreover, the current European fire design code for composite steel-concrete structures ( EN 1994-1-2) does not provide any simplified thermal model to evaluate the temperature evolution of each slim-floor part during a fire. Additionally, only a few experimental studies can be found which may help understand the thermal behaviour of these composite beams. This paper presents an experimental investigation on the thermal behaviour of slim-floor beams. Electrical radiative panels were used in the test setup to produce the thermal heating. The thermal gap between the lower flange of the steel profile and the bottom steel plate was studied, being found to be one of the most influential elements over the cross-section temperature gradient. The experimental campaign was developed by varying the cross-section configuration in order to evaluate the influence of this parameter over the slim-floor thermal behavior. Finally, the experiments carried out were used to develop and calibrate a finite element thermal model which may help in further research on the thermal behaviour of slim-floor composite beams.
引用
收藏
页码:819 / 823
页数:5
相关论文
共 50 条
  • [31] Effect of Load Ratios on the Behavior of Asymmetric Slim Floor Beams Exposed to Fire
    Sooyoung Park
    Heungyoul Kim
    Kappyo Hong
    Fire Technology, 2013, 49 : 907 - 926
  • [32] Effect of Load Ratios on the Behavior of Asymmetric Slim Floor Beams Exposed to Fire
    Park, Sooyoung
    Kim, Heungyoul
    Hong, Kappyo
    FIRE TECHNOLOGY, 2013, 49 (04) : 907 - 926
  • [33] Determination of moment resistance for composite shallow-floor beams - Additional design rules for slim-floor beams
    Schaefer, Markus
    STAHLBAU, 2015, 84 (04) : 231 - 238
  • [34] Fire resistance of composite slim floor beams
    Mäkeläinen, P
    Ma, ZC
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2000, 54 (03) : 345 - 363
  • [35] An Experimental Study on Fire Resistance of Slim Floor Beam
    Kim, Hyung Jun
    Kim, Heung You
    Park, Soo Young
    PERFORMANCE, PROTECTION AND STRENGTHENING OF STRUCTURES UNDER EXTREME LOADING, 2011, 82 : 752 - +
  • [36] Numerical modelling and analysis of dowel shear connector for composite slim-floor beams
    Xu, Xinxin
    Dai, Xianghe
    Lam, Dennis
    ADVANCES IN STRUCTURAL ENGINEERING, 2025,
  • [37] Effect of dowel shear connector on performance of slim-floor composite shear beams
    Dai, Xianghe
    Lam, Dennis
    Sheehan, Therese
    Yang, Jie
    Zhou, Kan
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2020, 173
  • [38] Internally fire protected composite steel-concrete slim-floor beam
    Albero, V.
    Serra, E.
    Espinos, A.
    Romero, M. L.
    Hospitaler, A.
    ENGINEERING STRUCTURES, 2021, 227
  • [39] Effect of dowel shear connector on performance of slim-floor composite shear beams
    Dai, Xianghe
    Lam, Dennis
    Sheehan, Therese
    Yang, Jie
    Zhou, Kan
    Dai, Xianghe (x.dai@bradford.ac.uk), 1600, Elsevier Ltd (173):
  • [40] Flexural behaviour of composite slim floor beams
    Sheehan, Therese
    Dai, Xianghe
    Yang, Jie
    Zhou, Kan
    Lam, Dennis
    STRUCTURES, 2019, 21 : 22 - 32