摘要
The purpose of this study was to determine ability of cyst aspiration and core biopsy to differentiate malignancies, and benign lesions needing intervention from benign complex cysts in the group of Bosmak 2F and 3 renal cysts. One hundred ninety-nine indeterminate complex renal cysts were biopsied under CT or US guidance using a coaxial system (19-G sheath, 20- or 21-G Chiba or Franseen or 18-G spring biopsy needle). Cytology, amylase, lipase, LDH, fat, protein, urea nitrogen, creatine, and culture and sensitivity were assessed in all patients, histopathology in 116, and flow cytometry in 32. In 179 patients (87.9%) a definitive diagnosis was made; in 20 the specimen was inadequate. Twenty of 28 malignancies were correctly diagnosed (sensitivity 0.71); 27 of 31 benign lesions needing intervention (sensitivity 0.87) and 128 of 140 benign complex cysts (sensitivity 0.91). All inconclusive biopsies were explored revealing six malignancies. There were four CT biopsy misdiagnoses: two renal cell carcinomas; one angiomyolipoma; and one abscess. Guided cyst puncture aspiration and core biopsy significantly altered management of Bosniak 3 and 2F renal cysts obviating surgery or invasive procedures in 70% of the patients with an affirmed diagnosis of benign complex cyst and rendering timely surgical and other interventions in the remaining patients. Long-term follow-up (mean 5.6 years) revealed no further misdiagnosis.
引用
收藏
页码:2518 / 2524
页数:7
相关论文
共 50 条
  • [31] Active Surveillance of Small (< 4 cm) Bosniak Category 2F, 3, and 4 Renal Lesions: What Happens on Imaging Follow-Up?
    Shaish, Hiram
    Ahmed, Firas
    Schreiber, Jessica
    Hindman, Nicole M.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2019, 212 (06) : 1215 - 1222
  • [32] Clinical value of CT-guided biopsy of small (≤1.5 cm) suspicious lung nodules: Diagnostic accuracy, molecular characterization and long-term clinical outcomes
    Tamrazi, Anobel
    Sundaresan, Srividya
    Parvizi, Amin
    Eller, Andrea
    Fujii, Juanita
    Shaheen, Zayna
    Campbell, Ann
    CANCER TREATMENT AND RESEARCH COMMUNICATIONS, 2022, 33
  • [33] The Diagnostic Accuracy of Percutaneous Renal Needle Core Biopsy and Its Potential Impact on the Clinical Management of Renal Cortical Neoplasms
    Gellert, Lan L.
    Mehra, Rohit
    Chen, Ying-Bei
    Gopalan, Anuradha
    Fine, Samson W.
    Al-Ahmadie, Hikmat
    Reuter, Victor E.
    Tickoo, Satish K.
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2014, 138 (12) : 1673 - 1679
  • [34] CT-guided thick needle percutaneous biopsy of pulmonary nodules smaller than 2 cm: technical aspects and factors that influence the accuracy
    de Andrade, Juliano Ribeiro
    Rocha, Rafael Dahmer
    Falsarella, Priscila Mina
    Rahal Junior, Antonio
    dos Santos, Ricardo Sales
    Franceschini, Juliana Pereira
    Fernando, Hiran Chrishantha
    Garcia, Rodrigo Gobbo
    JORNAL BRASILEIRO DE PNEUMOLOGIA, 2018, 44 (04) : 307 - 314
  • [35] Immediate Cytological Assessment of Touch Preparations of CT-guided Needle Core Biopsies of Renal Masses Improves Diagnostic Accuracy, Avoiding Repeat Procedures/Unnecessary Surgery
    Padmanabhan, V.
    Schned, A. R.
    Quinlisk, F. M.
    Forauer, A. R.
    Forauer, J. D.
    Seigne, J. D.
    Gonzalez, J. L.
    MODERN PATHOLOGY, 2009, 22 : 92A - 93A
  • [36] Immediate Cytological Assessment of Touch Preparations of CT-guided Needle Core Biopsies of Renal Masses Improves Diagnostic Accuracy, Avoiding Repeat Procedures/Unnecessary Surgery
    Padmanabhan, V.
    Schned, A. R.
    Quinlisk, F. M.
    Forauer, A. R.
    Seigne, J. D.
    Gonzalez, J. L.
    LABORATORY INVESTIGATION, 2009, 89 : 92A - 93A
  • [37] Effects of Contrast-Enhanced Ultrasound of Indeterminate Renal Masses on Patient Clinical Management Retrospective Analysis From 2 Institutions
    Eisenbrey, John R.
    Kamaya, Aya
    Gummadi, Sriharsha
    Bird, Kristen
    Burrowes, David
    Arias, Diego
    Lallas, Costas D.
    Trabulsi, Edouard J.
    Lyshchik, Andrej
    JOURNAL OF ULTRASOUND IN MEDICINE, 2021, 40 (01) : 131 - 139
  • [38] Contrast-Enhanced Ultrasound (CEUS) for Follow-Up of Bosniak 2F Complex Renal Cystic Lesions-A 12-Year Retrospective Study in a Specialized European Center
    Ruebenthaler, Johannes
    Cecatka, Sasa
    Froelich, Matthias Frank
    Stechele, Matthias
    Marschner, Constantin
    Sabel, Bastian Oliver
    Bogner, Florian
    Schnitzer, Moritz Ludwig
    Overhoff, Daniel
    Grosse Hokamp, Nils
    Staehler, Michael
    Schwarze, Vincent
    Clevert, Dirk-Andre
    CANCERS, 2020, 12 (08) : 1 - 17
  • [39] F-18-FDG PET/CT-Guided Clinical Management of the Rare Aggressive "Columnar-Cell" Variant of Papillary Thyroid Cancer
    Vadrucci, Manuela
    Serio, Giovanni
    Baroli, Alberto
    ENDOCRINOLOGY AND METABOLISM, 2016, 31 (02) : 343 - 344
  • [40] Stellenwert der CT-gesteuerten perkutanen Biopsie kleiner Tumoren in der Diagnostik des Nierenzellkarzinoms: aktueller StandAccuracy of CT-guided percutaneous biopsy of small masses in the diagnosis of renal cell carcinoma: status quo
    M. Regier
    J. Kemper
    A. Mahnken
    C. Nolte-Ernsting
    P.G.C. Begemann
    C. Eichelberg
    H. Heinzer
    H. Huland
    G. Adam
    Der Onkologe, 2008, 14 (10): : 1022 - 1031