Regional survey of CT dose indices in India

被引:4
|
作者
Livingstone, Roshan S. [1 ]
Dinakaran, Paul M. [1 ]
机构
[1] Christian Med Coll & Hosp, Dept Radiol, Vellore, Tamil Nadu, India
关键词
MULTISLICE; TOMOGRAPHY; REDUCTION; HEAD;
D O I
10.1093/rpd/ncp160
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study intends to evaluate the current level of computed tomography (CT) scanner doses installed in a region in India. In-site CT dose measurement was performed for 127 CT scanners in a region in India. CT dose index (CTDI) was measured using a 10 cm3 pencil ion chamber and 32-cm polymethyl methacrylate body phantom. The CT numbers and image noise were measured for the phantom using software available on each CT scanner. Of the 127 CT scanners, 13 were conventional, 53 helical single-section, 44 multidetector row CT (MDCT) and 17 refurbished machines. The mean-weighted CTDI (CTDIw) values calculated using standard exposure parameters for conventional, conventional refurbished, single-section helical scanner (SSHS), refurbished SSHS and MDCT scanners were 7.5, 6.53, 6.8, 6.6 and 7.04 mGy. Twenty-seven CT scanners had deranged CT numbers. Periodic quality assurance and regional dose surveys would be beneficial to set up regional reference levels in India.
引用
收藏
页码:222 / 227
页数:6
相关论文
共 50 条
  • [31] CT dose survey in adults: what sample size for what precision?
    Taylor, Stephen
    Van Muylem, Alain
    Howarth, Nigel
    Gevenois, Pierre Alain
    Tack, Denis
    EUROPEAN RADIOLOGY, 2017, 27 (01) : 365 - 373
  • [32] Multi-Period Regional Survey Data from Vidarbha, Maharashtra, India
    Hawkes, Jason
    Abbas, Riza
    Toraskar, Sitaram
    JOURNAL OF OPEN ARCHAEOLOGY DATA, 2020, 8
  • [33] Regional Differences of Housing Environments in India: Facts from National Sample Survey
    Ravishankar, A. K.
    JOURNAL OF HEALTH MANAGEMENT, 2018, 20 (01) : 91 - 103
  • [34] A regional dose and image quality survey for chest, abdomen and pelvis radiographs in paediatrics
    López, M
    Morant, JJ
    Geleijns, K
    Calzado, A
    RADIATION PROTECTION DOSIMETRY, 2000, 90 (1-2) : 275 - 278
  • [35] Radiation doses from low-dose CT scans in SPECT/CT and PET/CT examinations: A survey in Germany
    Rinscheid, Andreas
    Janzen, Tilman
    Alikhani, Babak
    Beer, Ambros J.
    Braune, Anja
    Eberhardt, Nina
    Fechner, Diana
    Foerster, Stefan
    Freesmeyer, Martin
    Furth, Christian
    Grunert, Michael
    Hellwig, Dirk
    Costa, Pedro Fragoso
    Kuehnel, Christian
    Lange, Catharina
    Linke, Rainer
    Razlaw, Natalia
    Sack, Tobias
    Schmidt, Daniel
    Schuetze, Christina
    Starke, Alexander
    Tondera, Liane
    Wengenmair, Hermann
    Zoephel, Klaus
    Burchert, Wolfgang
    Lapa, Constantin
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2022, 61 (04): : 294 - 300
  • [36] Regional survey of pediatric patient doses from CT examinations in Tehran, Iran
    Khosravi, H. R.
    Sadri, L.
    Setayeshi, S.
    Asnaashari, K.
    Midia, M.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, 2015, VOLS 1 AND 2, 2015, 51 : 771 - 774
  • [37] CT Radiation Dose for Computer-Assisted Endoscopic Sinus Surgery: Dose Survey and Determination of Dose-Reduction Limits
    Nauer, C. B.
    Eichenberger, A.
    Dubach, P.
    Gralla, J.
    Caversaccio, M.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2009, 30 (03) : 617 - 622
  • [38] Local Dose Survey on Paediatric Multi-detector CT: A Preliminary Result
    Lubis, L. E.
    Jundi, A. F.
    Susilo, A.
    Evianti, A.
    Soejoko, D. S.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING 2018, VOL 3, 2019, 68 (03): : 571 - 575
  • [39] Regional survey
    Geertsen, Herman
    TIJDSCHRIFT VOOR DIERGENEESKUNDE, 2007, 132 (22) : 859 - 859
  • [40] The multicompartment CT technique:: Regional measurements and reduction of radiation dose in body composition studies
    Lönn, L
    Starck, G
    QUALITY OF THE BODY CELL MASS: BODY COMPOSITION IN THE THIRD MILLENNIUM, 2000, : 187 - 197