Regional survey of CT dose indices in India

被引:4
|
作者
Livingstone, Roshan S. [1 ]
Dinakaran, Paul M. [1 ]
机构
[1] Christian Med Coll & Hosp, Dept Radiol, Vellore, Tamil Nadu, India
关键词
MULTISLICE; TOMOGRAPHY; REDUCTION; HEAD;
D O I
10.1093/rpd/ncp160
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This study intends to evaluate the current level of computed tomography (CT) scanner doses installed in a region in India. In-site CT dose measurement was performed for 127 CT scanners in a region in India. CT dose index (CTDI) was measured using a 10 cm3 pencil ion chamber and 32-cm polymethyl methacrylate body phantom. The CT numbers and image noise were measured for the phantom using software available on each CT scanner. Of the 127 CT scanners, 13 were conventional, 53 helical single-section, 44 multidetector row CT (MDCT) and 17 refurbished machines. The mean-weighted CTDI (CTDIw) values calculated using standard exposure parameters for conventional, conventional refurbished, single-section helical scanner (SSHS), refurbished SSHS and MDCT scanners were 7.5, 6.53, 6.8, 6.6 and 7.04 mGy. Twenty-seven CT scanners had deranged CT numbers. Periodic quality assurance and regional dose surveys would be beneficial to set up regional reference levels in India.
引用
收藏
页码:222 / 227
页数:6
相关论文
共 50 条
  • [1] Assessment of Regional Computed Tomography Dose Indices in India Towards Establishing DRL
    Kumar, A. Saravana
    Rajakumar, R.
    Jose, A.
    Balalakshmoji, D.
    MEDICAL PHYSICS, 2019, 46 (06) : E161 - E161
  • [2] Application of draft European Commission reference levels to a regional CT dose survey
    Clarke, J
    Cranley, K
    Robinson, J
    Smith, PHS
    Workman, A
    BRITISH JOURNAL OF RADIOLOGY, 2000, 73 (865): : 43 - 50
  • [3] ACR Dose Index Registry for Comparing CT Dose Indices
    Morin, R.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [4] The first UK survey of dose indices from radiotherapy treatment planning CT scans for adult patients
    Williams, M.
    Wood, T.
    Davis, A.
    Earley, J.
    Plaistow, R.
    Lindsay, R.
    Palmer, A.
    Nesbit, A.
    Edyvean, S.
    Findlay, U.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S318 - S318
  • [5] Regional anaesthesia practices in India: A nationwide survey
    Malhotra, Naveen
    Ramachandran, Srinivasan
    Velayudhan, Savitri
    Bajwa, SukhminderJit Singh
    Joshi, Muralidhar
    Mehdiratta, Lalit
    Hiremath, VishwanathR
    INDIAN JOURNAL OF ANAESTHESIA, 2021, 65 (12) : 853 - 861
  • [6] Survey of CT dose for PET/CT localization and attenuation correction
    Jallow, Ngoneh
    Nye, Jonathon
    Christian, Paul
    Sunderland, John
    Graham, Michael
    Hoffman, John
    JOURNAL OF NUCLEAR MEDICINE, 2015, 56 (03)
  • [7] A national survey on radiation dose in CT in The Netherlands
    van der Molen, A. J.
    Schilham, A.
    Stoop, P.
    Prokop, M.
    Geleijns, J.
    INSIGHTS INTO IMAGING, 2013, 4 (03): : 383 - 390
  • [8] CT Dose Survey for Simulations in Radiation Oncology
    Rice, R.
    Kim, G.
    Wang, J.
    Pawlicki, T.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [9] A national survey on radiation dose in CT in The Netherlands
    A. J. van der Molen
    A. Schilham
    P. Stoop
    M. Prokop
    J. Geleijns
    Insights into Imaging, 2013, 4 (3) : 383 - 390
  • [10] Dose indices in dental cone beam CT and correlation with dose-area product
    Araki, K.
    Patil, S.
    Endo, A.
    Okano, T.