DETERMINATION OF MELAMINE BASED ON THE FORMATION OF AN INSOLUBLE COPPER-MELAMINE COMPLEX AND FLAME ATOMIC ABSORPTION SPECTROMETRY

被引:5
|
作者
Bhawawet, Nakara [1 ]
Fuangswasdi, Saowarux [1 ]
Imyim, Apichat [1 ]
机构
[1] Chulalongkorn Univ, Dept Chem, Fac Sci, Bangkok 10330, Thailand
关键词
Copper(II); FAAS; Flame atomic absorption spectrometry; Melamine; MILK; RESIDUE;
D O I
10.1080/00032719.2014.888728
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A copper-melamine complex was optimally synthesized by heating excess copper(II), as 50 m mol L-1 copper(II) chloride in 50%(v/v) methanol, and melamine at 80 degrees C. The amount of residual copper(II) in solution after removal of the copper-melamine complex was then measured by flame atomic absorption spectrometry. The concentration of depleted copper was proportional to the concentration of melamine, with a linear calibration curve (melamine concentration against copper absorbance) between 0.5 and 2.5 m mol L-1 (R-2 = 0.9943) and with a limit of detection of 0.50 m mol L-1. Although external standard calibration provided poor recoveries in fortified fish flesh (40% to 74% for 5 to 10 mg melamine/g), the method of standard addition provided acceptable values (90% to 93%), with a relative standard deviation of 3% to 10%. The results obtained with the standard addition method were in broad agreement with those obtained by high performance liquid chromatography.
引用
收藏
页码:1931 / 1937
页数:7
相关论文
共 50 条