DETERMINATION OF MELAMINE BASED ON THE FORMATION OF AN INSOLUBLE COPPER-MELAMINE COMPLEX AND FLAME ATOMIC ABSORPTION SPECTROMETRY

被引:5
|
作者
Bhawawet, Nakara [1 ]
Fuangswasdi, Saowarux [1 ]
Imyim, Apichat [1 ]
机构
[1] Chulalongkorn Univ, Dept Chem, Fac Sci, Bangkok 10330, Thailand
关键词
Copper(II); FAAS; Flame atomic absorption spectrometry; Melamine; MILK; RESIDUE;
D O I
10.1080/00032719.2014.888728
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A copper-melamine complex was optimally synthesized by heating excess copper(II), as 50 m mol L-1 copper(II) chloride in 50%(v/v) methanol, and melamine at 80 degrees C. The amount of residual copper(II) in solution after removal of the copper-melamine complex was then measured by flame atomic absorption spectrometry. The concentration of depleted copper was proportional to the concentration of melamine, with a linear calibration curve (melamine concentration against copper absorbance) between 0.5 and 2.5 m mol L-1 (R-2 = 0.9943) and with a limit of detection of 0.50 m mol L-1. Although external standard calibration provided poor recoveries in fortified fish flesh (40% to 74% for 5 to 10 mg melamine/g), the method of standard addition provided acceptable values (90% to 93%), with a relative standard deviation of 3% to 10%. The results obtained with the standard addition method were in broad agreement with those obtained by high performance liquid chromatography.
引用
收藏
页码:1931 / 1937
页数:7
相关论文
共 50 条
  • [1] A Electrochemical Sensor for Melamine Detection Based on Copper-Melamine Complex Using OMC Modified Glassy Carbon Electrode
    Zhuo Guo
    Yang-ting Zhao
    Ya-hui Li
    Tong Bao
    Tian-shuai Sun
    Dong-di Li
    Xian-ke Luo
    Hong-tao Fan
    Food Analytical Methods, 2018, 11 : 546 - 555
  • [2] A Electrochemical Sensor for Melamine Detection Based on Copper-Melamine Complex Using OMC Modified Glassy Carbon Electrode
    Guo, Zhuo
    Zhao, Yang-ting
    Li, Ya-hui
    Bao, Tong
    Sun, Tian-shuai
    Li, Dong-di
    Luo, Xian-ke
    Fan, Hong-tao
    FOOD ANALYTICAL METHODS, 2018, 11 (02) : 546 - 555
  • [3] Determination of Copper and Chromium in Red Wine by Flame Atomic Absorption Spectrometry
    Guo Jinying
    Song Lixia
    Li Li
    Liu Kaiyong
    Li Songbiao
    Hou Yuze
    Cui Guoting
    PROCEEDINGS OF THE SIXTH INTERNATIONAL SYMPOSIUM ON VITICULTURE AND ENOLOGY, 2009, : 206 - 212
  • [5] DETERMINATION OF COPPER, IRON, LEAD AND ZINC IN COMPLEX SULFIDE MATERIALS BY FLAME ATOMIC-ABSORPTION SPECTROMETRY
    ALVIN, JF
    GARDINER, FR
    ANALYST, 1986, 111 (08) : 897 - 899
  • [6] Electrochemical sensor for melamine based on its copper complex
    Zhu, Hong
    Zhang, Songxin
    Li, Meixian
    Shao, Yuanhua
    Zhu, Zhiwei
    CHEMICAL COMMUNICATIONS, 2010, 46 (13) : 2259 - 2261
  • [7] Manganese sensitised-indirect determination of melamine in milk-based samples by flame atomic absorption spectrometry coupled with ultrasound assisted-cloud point extraction
    Gurkan, Ramazan
    Temel, Nuket Kartal
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2020, 100 (02) : 152 - 174
  • [8] Determination of copper, magnesium and zinc in mononuclear leukocytes by flame atomic absorption spectrometry
    Rahn-Chique, Kareem
    Carrion, Nereida
    Murillo, Miguel
    INVESTIGACION CLINICA, 2012, 53 (04): : 342 - 352
  • [9] Copper complex formation with the groups of heterocyclic amines in polymeric melamine-based sorbents
    Myasoedova, GV
    Marov, IN
    Belyaeva, VK
    Shcherbinina, NI
    Kolobov, SS
    ZHURNAL NEORGANICHESKOI KHIMII, 1997, 42 (11): : 1844 - 1846
  • [10] Determination of Copper in Human Urine by Cloud Point Extraction and Flame Atomic Absorption Spectrometry
    Prochazkova, Simona
    Halko, Radoslav
    ANALYTICAL LETTERS, 2016, 49 (11) : 1656 - 1668