Assessment of Prosthesis Alignment after Revision Total Knee Arthroplasty Using EOS 2D and 3D Imaging: A Reliability Study

被引:26
|
作者
Meijer, Marrigje F. [1 ]
Boerboom, Alexander L. [1 ]
Stevens, Martin [1 ]
Bulstra, Sjoerd K. [1 ]
Reininga, Inge H. F. [2 ]
机构
[1] Univ Groningen, Univ Med Ctr Groningen, Dept Orthopaed, Groningen, Netherlands
[2] Univ Groningen, Univ Med Ctr Groningen, Dept Trauma Surg, Groningen, Netherlands
来源
PLOS ONE | 2014年 / 9卷 / 09期
关键词
LOWER-EXTREMITY; REPRODUCIBILITY; REHABILITATION; AGREEMENT; POSITION; ROTATION; SYSTEM;
D O I
10.1371/journal.pone.0104613
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Introduction: A new low-dose X-ray device, called EOS, has been introduced for determining lower-limb alignment in 2D and 3D. Reliability has not yet been assessed when using EOS on lower limbs containing a knee prosthesis. Therefore purpose of this study was to determine intraobserver and interobserver reliability of EOS 2D and 3D knee prosthesis alignment measurements after revision total knee arthroplasty (rTKA). Methods: Forty anteroposterior and lateral images of 37 rTKA patients were included. Two observers independently performed measurements on these images twice. Varus/valgus angles were measured in 2D (VV2D) and 3D (VV3D). Intraclass correlation coefficients and the Bland and Altman method were used to determine reliability. T-tests were used to test potential differences. Results: Intraobserver and interobserver reliability were excellent for VV2D and VV3D. No significant difference or bias between the first and second measurements or the two observers was found. A significant mean and absolute difference of respectively 1.00 degrees and 1.61 degrees existed between 2D and 3D measurements. Conclusions: EOS provides reliable varus/valgus measurements in 2D and 3D for the alignment of the knee joint with a knee prosthesis. However, significant differences exist between varus/valgus measurements in 2D and 3D.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Comparing reliability between 3D imaging and 2D photography for external nasal anthropometry
    Yoon-Soo Seo
    Ki-Hun Jo
    Joo-Yeon Kim
    Jae-Hwan Kwon
    Scientific Reports, 12
  • [42] Dose Assessment in 2D and 3D Mammography
    Saadi, S.
    Merad, A.
    Khelassi-Toutaoui, N.
    Boubrit, M.
    1ST INTERNATIONAL CONFERENCE ON RADIATIONS AND APPLICATIONS (ICRA-2017), 2018, 1994
  • [43] The nasopalatine canal revisited using 2D and 3D CT imaging
    Mraiwa, N
    Jacobs, R
    Van Cleynenbreugel, J
    Sanderink, G
    Schutyser, F
    Suetens, P
    van Steenberghe, D
    Quirynen, M
    DENTOMAXILLOFACIAL RADIOLOGY, 2004, 33 (06) : 396 - 402
  • [44] 3D Passive Imaging of Ultrasound Cavitation using a 2D Array
    Boulos, Paul
    Varray, Francois
    Gilles, Bruno
    Bera, Jean-Christophe
    Cachard, Christian
    2017 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2017,
  • [45] Assessment of 2D and 3D imaging for patients undergoing laparoscopic bariatric surgery
    Thapa, Dil Momin
    Wang, Mofei
    POLISH JOURNAL OF SURGERY, 2023, 95 (01) : 35 - 39
  • [46] Accuracy evaluation of fluoroscopy-based 2D and 3D pose reconstruction with unicompartmental knee arthroplasty
    Van Duren, B. H.
    Pandit, H.
    Beard, D. J.
    Murray, D. W.
    Gill, H. S.
    MEDICAL ENGINEERING & PHYSICS, 2009, 31 (03) : 356 - 363
  • [47] 3D AAM Based Face Alignment under Wide Angular Variations using 2D and 3D Data
    Wang, Hao-Hsueh
    Dopfer, Andreas
    Wang, Chieh-Chih
    2012 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION (ICRA), 2012, : 4450 - 4455
  • [48] Homogeneous 2D and 3D Alignment of Cardiomyocytes in Dilated Cardiomyopathy Revealed by Intravital Heart Imaging
    Masuyama, Kiyoshi
    Higo, Tomoaki
    Lee, Jong-Kook
    Miyagawa, Shigeru
    Sawa, Yoshiki
    Sakata, Yasushi
    CIRCULATION, 2020, 142
  • [49] Homogeneous 2D and 3D alignment of cardiomyocyte in dilated cardiomyopathy revealed by intravital heart imaging
    Kiyoshi Masuyama
    Tomoaki Higo
    Jong-Kook Lee
    Ryohei Matsuura
    Ian Jones
    Chris Bakal
    Shuichiro Higo
    Sachio Morimoto
    Shigeru Miyagawa
    Yoshiki Sawa
    Yasushi Sakata
    Scientific Reports, 11
  • [50] Homogeneous 2D and 3D alignment of cardiomyocyte in dilated cardiomyopathy revealed by intravital heart imaging
    Masuyama, Kiyoshi
    Higo, Tomoaki
    Lee, Jong-Kook
    Matsuura, Ryohei
    Jones, Ian
    Bakal, Chris
    Higo, Shuichiro
    Morimoto, Sachio
    Miyagawa, Shigeru
    Sawa, Yoshiki
    Sakata, Yasushi
    SCIENTIFIC REPORTS, 2021, 11 (01)