Realistic Fetus Skin Color Processing for Ultrasound Volume Rendering

被引:0
|
作者
Kim, Yun-Tae [1 ]
Kim, Kyuhong [1 ]
Park, Sung-Chan [1 ]
Kang, Jooyoung [1 ]
Kim, Jung-Ho [1 ]
机构
[1] Samsung Elect, SAIT, Med Syst Lab, Yongin 446712, Gyeonggi Do, South Korea
关键词
volume rendering; ray casting; color map; tone mapping function (TMF); IMAGES;
D O I
10.1117/12.2037151
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
This paper proposes realistic fetus skin color processing using a 2D color map and a tone mapping function (TMF) for ultrasound volume rendering. The contributions of this paper are a 2D color map generated through a gamut model of skin color and a TMF that depends on the lighting position. First, the gamut model of fetus skin color is calculated by color distribution of baby images. The 2D color map is created using a gamut model for tone mapping of ray casting. For the translucent effect, a 2D color map in which lightness is inverted is generated. Second, to enhance the contrast of rendered images, the luminance, color, and tone curve TMF parameters are changed using 2D Gaussian function that depends on the lighting position. The experimental results demonstrate that the proposed method achieves better realistic skin color reproduction than the conventional method.
引用
收藏
页数:8
相关论文
共 50 条
  • [31] Optimized Graphical Processing Unit Processing Framework for Surface Rendering in 4D Ultrasound Imaging
    Elnokrashy, Ahmed F.
    Hussein, Marwan H.
    Hosny, Tamer
    Ali, Ahmed
    Megawer, Alaa
    Hendy, Amr M.
    Kadah, Yasser M.
    JOURNAL OF MEDICAL IMAGING AND HEALTH INFORMATICS, 2014, 4 (02) : 197 - 202
  • [32] Remote Assessment of Heart Rate by Skin Color Processing
    Bogdan, Gavriloaia
    Radu, Vizireanu
    Octavian, Fratu
    Alin, Berechet
    Constantin, Mara
    Cristian, Cucu
    2015 IEEE INTERNATIONAL BLACK SEA CONFERENCE ON COMMUNICATIONS AND NETWORKING (BLACKSEACOM), 2015, : 112 - 116
  • [33] Fast re-rendering of volume and surface graphics by depth, color, and opacity buffering
    Bhalerao, A
    Pfister, H
    Halle, M
    Kikinis, R
    MEDICAL IMAGE ANALYSIS, 2000, 4 (03) : 235 - 251
  • [34] Robust processing of intracranial CT angiograms for 3D volume rendering
    E. A. Moore
    J. P. Grieve
    H. R. Jäger
    European Radiology, 2001, 11 : 137 - 141
  • [35] Robust processing of intracranial CT angiograms for 3D volume rendering
    Moore, EA
    Grieve, JP
    Jäger, HR
    EUROPEAN RADIOLOGY, 2001, 11 (01) : 137 - 141
  • [36] Cardiac vectors in the healthy human fetus: developmental changes assessed by magnetocardiography and realistic approximations of the volume conductor
    Tao, R.
    Popescu, E. A.
    Drake, W. B.
    Popescu, M.
    PHYSIOLOGICAL MEASUREMENT, 2013, 34 (05) : 527 - 540
  • [37] 3-DIMENSIONAL ULTRASOUND - ABNORMALITIES OF THE FETAL FACE IN SURFACE AND VOLUME RENDERING MODE
    LEE, A
    DEUTINGER, J
    BERNASCHEK, G
    BRITISH JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 1995, 102 (04): : 302 - 306
  • [38] Adaptive design of a global opacity transfer function for direct volume rendering of ultrasound data
    Hönigmann, D
    Ruisz, J
    Haider, C
    IEEE VISUALIZATION 2003, PROCEEDINGS, 2003, : 489 - 496
  • [39] Three-dimensional ultrasound performed with perspective volume rendering: Technique and clinical applications
    Yuh, EL
    Jeffrey, RB
    Birdwell, RL
    Chen, BH
    Napel, S
    RADIOLOGY, 1998, 209P : 265 - 265
  • [40] Interactive volume rendering of real-time three-dimensional ultrasound images
    Kuo, Johnny
    Bredthauer, Gregory R.
    Castellucci, John B.
    von Ramm, Olaf T.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (02) : 313 - 318