Effects of pole compliance and step frequency on the biomechanics and economy of pole carrying during human walking

被引:33
|
作者
Castillo, Eric R. [1 ]
Lieberman, Graham M. [2 ]
McCarty, Logan S. [3 ,4 ]
Lieberman, Daniel E. [1 ]
机构
[1] Harvard Univ, Dept Human Evolutionary Biol, Cambridge, MA 02138 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
[3] Harvard Univ, Dept Phys, Cambridge, MA 02138 USA
[4] Harvard Univ, Dept Chem & Biol Chem, Cambridge, MA 02138 USA
基金
美国国家科学基金会;
关键词
load carrying; gait; locomotion; energetics; mass-spring model; natural frequency; harmonic motion; DYNAMIC SIMILARITY HYPOTHESIS; ENERGETIC COST; LOAD CARRIAGE; TRANSPORT; EVOLUTION; ORIGIN; FORCE;
D O I
10.1152/japplphysiol.00119.2014
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
This study investigates whether a flexible pole can be used as an energy-saving method for humans carrying loads. We model the carrier and pole system as a driven damped harmonic oscillator and predict that the energy expended by the carrier is affected by the compliance of the pole and the ratio between the pole's natural frequency and the carrier's step frequency. We tested the model by measuring oxygen consumption in 16 previously untrained male participants walking on a treadmill at four step frequencies using two loaded poles: one made of bamboo and one of steel. We found that when the bamboo pole was carried at a step frequency 20% greater than its natural frequency, the motions of the centers of mass of the load and carrier were approximately equal in amplitude and opposite in phase, which we predicted would save energy for the carrier. Carrying the steel pole, however, resulted in the carrier and loads oscillating in phase and with roughly equal amplitude. Although participants were less economical using poles than predicted costs using conventional fixed-load techniques (such as backpacks), the bamboo pole was on average 5.0% less costly than the steel pole. When allowed to select their cadence, participants also preferred to carry the bamboo pole at step frequencies of similar to 2.0 Hz. This frequency, which is significantly higher than the preferred unloaded step frequency, is most economical. These experiments suggest that pole carriers can intuitively adjust their gaits, or choose poles with appropriate compliance, to increase energetic savings.
引用
收藏
页码:507 / 517
页数:11
相关论文
共 50 条
  • [31] Patterns of trunk muscle activation during walking and pole walking using statistical non-parametric mapping
    Zoffoli, Luca
    Ditroilo, Massimiliano
    Federici, Ario
    Lucertini, Francesco
    JOURNAL OF ELECTROMYOGRAPHY AND KINESIOLOGY, 2017, 37 : 52 - 60
  • [32] Do poles really “save the legs” during uphill pole walking at different intensities?
    Nicola Giovanelli
    Barbara Pellegrini
    Lorenzo Bortolan
    Lara Mari
    Federico Schena
    Stefano Lazzer
    European Journal of Applied Physiology, 2023, 123 : 2803 - 2812
  • [33] Photolysis frequency measurements at the South Pole during ISCAT-98
    Lefer, BL
    Hall, SR
    Cinquini, L
    Shetter, RE
    GEOPHYSICAL RESEARCH LETTERS, 2001, 28 (19) : 3637 - 3640
  • [34] Does the passability of apertures change when walking through human versus pole obstacles?
    Hackney, Amy L.
    Cinelli, Michael E.
    Frank, James S.
    ACTA PSYCHOLOGICA, 2015, 162 : 62 - 68
  • [35] Angular momentum regulation during human walking: Biomechanics and control
    Popovic, M
    Hofmann, A
    Herr, H
    2004 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND AUTOMATION, VOLS 1- 5, PROCEEDINGS, 2004, : 2405 - 2411
  • [36] STEP LENGTH, STEP FREQUENCY AND TEMPORAL FACTORS OF STRIDE IN NORMAL HUMAN WALKING
    CHATINIER, KD
    MOLEN, NH
    ROZENDAL, RH
    PROCEEDINGS OF THE KONINKLIJKE NEDERLANDSE AKADEMIE VAN WETENSCHAPPEN SERIES C-BIOLOGICAL AND MEDICAL SCIENCES, 1970, 73 (02) : 214 - +
  • [37] Comparison of the Effects of Walking with and without Nordic Pole on Upper Extremity and Lower Extremity Muscle Activation
    Shim, Je-myung
    Kwon, Hae-yeon
    Kim, Ha-roo
    Kim, Bo-in
    Jung, Ju-hyeon
    JOURNAL OF PHYSICAL THERAPY SCIENCE, 2013, 25 (12) : 1553 - 1556
  • [38] Biomechanics analysis of human lower limb during walking for exoskeleton design
    Chen, Jianhua
    Mu, Xihui
    Du, Fengpo
    JOURNAL OF VIBROENGINEERING, 2017, 19 (07) : 5527 - 5539
  • [39] Distinct fast and slow processes contribute to the selection of preferred step frequency during human walking
    Snaterse, Mark
    Ton, Robert
    Kuo, Arthur D.
    Donelan, J. Maxwell
    JOURNAL OF APPLIED PHYSIOLOGY, 2011, 110 (06) : 1682 - 1690
  • [40] A low-cost method for carrying loads during human walking
    Arellano, Christopher J.
    McReynolds, Obioma B.
    Thomas, Shernice A.
    JOURNAL OF EXPERIMENTAL BIOLOGY, 2020, 223 (23):