Vibro-acoustic and nonlinear analysis of cadavric femoral bone impaction in cavity preparations

被引:6
|
作者
Oberst, Sebastian [1 ,2 ,3 ,6 ]
Baetz, Johanna [4 ]
Campbell, Graeme [4 ]
Lampe, Frank [5 ]
Leis, Joseph C. S. [6 ]
Hoffmann, Norbert [2 ,3 ]
Morlock, Michael [4 ]
机构
[1] Univ Technol Sydney, Fac Engn & Informat Technol, Ctr Audio Acoust & Vibrat, Sydney, NSW, Australia
[2] Hamburg Univ Technol, Mech Engn, Dynam Grp, Hamburg, Germany
[3] Imperial Coll London, Dept Mech Engn, London, England
[4] Hamburg Univ Technol, Mech Engn, Inst Biomech, Hamburg, Germany
[5] Hamburg Univ Appl Sci, Dept Life Sci, Hamburg, Germany
[6] Univ New South Wales Canberra, Sch Engn & IT, Canberra, ACT, Australia
关键词
D O I
10.1051/matecconf/201814814007
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Owing to an ageing population, the impact of unhealthy lifestyle, or simply congenital or gender specific issues (dysplasia), degenerative bone and joint disease (osteoarthritis) at the hip pose an increasing problem in many countries. Osteoarthritis is painful and causes mobility restrictions; amelioration is often only achieved by replacing the complete hip joint in a total hip arthroplasty (THA). Despite significant orthopaedic progress related to THA, the success of the surgical process relies heavily on the judgement, experience, skills and techniques used of the surgeon. One common way of implanting the stem into the femur is press fitting uncemented stem designs into a prepared cavity. By using a range of compaction broaches, which are impacted into the femur, the cavity for the implant is formed. However, the surgeon decides whether to change the size of the broach, how hard and fast it is impacted or when to stop the excavation process, merely based on acoustic, haptic or visual cues which are subjective. It is known that non-ideal cavity preparations increase the risk of peri-prosthetic fractures especially in elderly people. This study reports on a simulated hip replacement surgery on a cadaver and the analysis of impaction forces and the microphone signals during compaction. The recorded transient signals of impaction forces and acoustic pressures (approximate to 80 mu s - 2 ms) are statistically analysed for their trend, which shows increasing heteroscedasticity in the force-pressure relationship between broach sizes. TIKHONOV regularisation, as inverse deconvolution technique, is applied to calculate the acoustic transfer functions from the acoustic responses and their mechanical impacts. The extracted spectra highlight that system characteristics altered during the cavity preparation process: in the high-frequency range the number of resonances increased with impacts and broach size. By applying nonlinear time series analysis the system dynamics increase in complexity and demand for a larger minimum embedding dimension. The growing number of resonances with similar level of the transfer function indicates a higher propensity to dissipate energy over sound; the change in embedding dimension indicates a decrease in linearity. The spectral changes as well as the altered dimension requirements indicate either an improved coupling between the bone and the broach or the onset of micro-fractures caused by growing stress levels within the bone.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] VIBRO-ACOUSTIC ANALYSIS OF PASSENGER COMPARTMENT
    Coroian, Adrian
    Lupea, Iulian
    ACTA TECHNICA NAPOCENSIS SERIES-APPLIED MATHEMATICS MECHANICS AND ENGINEERING, 2012, 55 (04): : 831 - 836
  • [22] Vibro-acoustic analysis of composite plates
    Sarigul, A. S.
    Karagozlu, E.
    2ND INTERNATIONAL CONFERENCE ON MATHEMATICAL MODELING IN PHYSICAL SCIENCES 2013 (IC-MSQUARE 2013), 2014, 490
  • [23] Vibro-Acoustic Analysis for Muffler Design
    Zhou, Ze
    SOUND AND VIBRATION, 2014, 48 (12): : 15 - 16
  • [24] Analysis of the Vibro-Acoustic Behavior of a Stiffened Double Panel-Cavity System
    Wang, Na
    Chen, Mingfei
    Zhang, Yantao
    Shi, Shuangxia
    Jin, Guoyong
    Liu, Zhigang
    SHOCK AND VIBRATION, 2022, 2022
  • [25] Modeling and vibro-acoustic behavior analysis of a plate-cavity coupling system equipped with a nonlinear energy sink
    Chen, Yilin
    Du, Jingtao
    Zhao, Yuhao
    Liu, Yang
    THIN-WALLED STRUCTURES, 2024, 200
  • [26] Vibro-acoustic and buckling analysis of a thermal plate-cavity coupled system
    Luo, Qing
    Wang, Yanfeng
    Yang, Yukang
    Xu, Qi
    Li, Yinghui
    Cheng, Li
    INTERNATIONAL JOURNAL OF MECHANICAL SCIENCES, 2024, 263
  • [27] Analysis of the Vibro-Acoustic Behavior of a Stiffened Double Panel-Cavity System
    Wang, Na
    Chen, Mingfei
    Zhang, Yantao
    Shi, Shuangxia
    Jin, Guoyong
    Liu, Zhigang
    SHOCK AND VIBRATION, 2022, 2022
  • [28] Damage assessment with nonlinear vibro-acoustic modulation technique
    Donskoy, Dimitri
    Zagrai, Andrei
    Chudnovsky, Alexander
    Golovin, Eduard
    Agarwala, Vinod
    PROCEEDINGS OF THE ASME INTERNATIONAL DESIGN ENGINEERING TECHNICAL CONFERENCE AND INFORMATION IN ENGINEERING CONFERENCE, VOL 1, PTS A-C, 2008, : 1949 - 1956
  • [29] Damage imaging in nonlinear vibro-acoustic modulation tests
    Pieczonka, Lukasz
    Klepka, Andrzej
    Uhl, Tadeusz
    Staszewski, Wieslaw J.
    HEALTH MONITORING OF STRUCTURAL AND BIOLOGICAL SYSTEMS 2015, 2015, 9438
  • [30] Nonlinear Vibro-acoustic Interactions for Crack Detection in Beams
    Broda, Dariusz
    Pieczonka, Lukasz
    Hiwarkar, Vikrant
    Staszewski, Wieslaw J.
    Silberschmidt, Vadim V.
    STRUCTURAL HEALTH MONITORING 2015: SYSTEM RELIABILITY FOR VERIFICATION AND IMPLEMENTATION, VOLS. 1 AND 2, 2015, : 1443 - 1450