Pentacyanoammineferrate-Based Non-Enzymatic Electrochemical Biosensing Platform for Selective Uric Acid Measurement

被引:6
|
作者
Jeon, Won-Yong [1 ]
Lee, Chang-Jun [2 ]
Sut, Tun Naw [1 ]
Kim, Hyug-Han [2 ]
Choi, Young-Bong [2 ]
机构
[1] Sungkyunkwan Univ, Biomed Inst Convergence, Sch Chem Engn, Suwon 16419, South Korea
[2] Dankook Univ, Dept Chem, Coll Nat Sci, Cheonan 31116, Chungnam, South Korea
基金
新加坡国家研究基金会;
关键词
uric acid; pentagonal metal complex; non-enzymatic electrochemical biosensor; nickel ion;
D O I
10.3390/s21051574
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical-based detection of uric acid (UA) is widely used for diagnostic purposes. However, various interfering species such as ascorbic acid, dopamine, and glucose can affect electrochemical signals, and hence there is an outstanding need to develop improved sensing platforms to detect UA with high selectivity. Herein, we report a pentagonal mediator-based non-enzymatic electrochemical biosensing platform to selectively measure UA in the presence of interfering species. The working electrode was fabricated by electrodepositing polymerized 1-vinylimidazole (PVI), which has an imidazole ligand, onto indium tin oxide (ITO), and then conjugating nickel ions to the PVI-coated ITO electrode. Electrode performance was characterized by cyclic voltammetry (CV) and electrochemical impedance spectroscopy (EIS) measurements and integrated together with pentacyanoammineferrate, which can bind to the amine groups of UA and function as an electron transferring mediator. The experimental results showed a wide linear range of UA concentration-dependent responses and the multi-potential step (MPS) technique facilitated selective detection of UA in the presence of physiologically relevant interfering species. Altogether, these findings support that pentacyanoammineferrate-based non-enzymatic electrodes are suitable biosensing platforms for the selective measurement of UA, and such approaches could potentially be extended to other bioanalytes as well.
引用
收藏
页码:1 / 14
页数:14
相关论文
共 50 条
  • [41] Deposition of Ni/RGO nanocomposite on conductive cotton fabric as non-enzymatic wearable electrode for electrochemical sensing of uric acid in sweat
    Singh, Anoop
    Sharma, Asha
    Arya, Sandeep
    DIAMOND AND RELATED MATERIALS, 2022, 130
  • [42] Review-Trends in the Development of Non-Enzymatic Electrochemical Sensors Modified with a Metal-Organic Framework for Quantification of Uric Acid
    Hernandez-Ramirez, D.
    Mendoza-Huizar, L. H.
    Galan-Vidal, C. A.
    Aguilar-Lira, G. Y.
    Alvarez-Romero, G. A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2022, 169 (05)
  • [43] Review-Trends on the Development of Non-Enzymatic Electrochemical Sensors Modified with Metal-Oxide Nanostructures for the Quantification of Uric Acid
    Hernandez-Ramirez, D.
    Mendoza-Huizar, L. H.
    Aguilar-Lira, G. Y.
    Alvarez-Romero, G. A.
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2021, 168 (05)
  • [44] SERS-Based Non-Enzymatic Detection of Uric Acid Using Au/CeO2 Nanorods
    Li, Yifei
    Li, Peng
    Qi, Mengyao
    Zhang, Xia
    Meng, Jun
    ACS APPLIED NANO MATERIALS, 2024, 7 (17) : 20920 - 20932
  • [45] Highly sensitive and selective rGO based Non-Enzymatic electrochemical sensor for propamocarb fungicide pesticide detection
    Tasaltin, Nevin
    Karakus, Selcan
    Tasaltin, Cihat
    Baytemir, Gulsen
    FOOD CHEMISTRY, 2022, 372
  • [46] ZnS and Reduced Graphene Oxide Nanocomposite-Based Non-Enzymatic Biosensor for the Photoelectrochemical Detection of Uric Acid
    Zhao, Yao
    Peng, Niancai
    Gao, Weizhuo
    Hu, Fei
    Zhang, Chuanyu
    Wei, Xueyong
    BIOSENSORS-BASEL, 2024, 14 (10):
  • [47] A Non-Enzymatic Electrochemical Sensing Platform Based on Hemin@MOF Composites for Detecting Hydrogen Peroxide and DNA
    Cheng, Dan
    Xiao, Xuelian
    Li, Xi
    Wang, Chen
    Liang, Yani
    Yu, Zhengsong
    Jin, Chenglong
    Zhou, Nan
    Chen, Ming
    Dong, Yulin
    Lin, Yawei
    Xie, Zhizhong
    Zhang, Chaocan
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2018, 165 (16) : B885 - B892
  • [48] Enzymatic and non-enzymatic electrochemical glucose sensor based on carbon nano-onions
    Mohapatra, Jeotikanta
    Ananthoju, Balakrishna
    Nair, Vishnu
    Mitra, Arijit
    Bahadur, D.
    Medhekar, N. V.
    Aslam, M.
    APPLIED SURFACE SCIENCE, 2018, 442 : 332 - 341
  • [49] Electrodeposited copper bismuth oxide as a low-cost, non-enzymatic electrochemical sensor for sensitive detection of uric acid and hydrogen peroxide
    Sinha, Gudipati Neeraja
    Subramanyam, Palyam
    Sivaramakrishna, Vanjari
    Subrahmanyam, Challapalli
    INORGANIC CHEMISTRY COMMUNICATIONS, 2021, 129
  • [50] Non-enzymatic Electrochemical Sensor for the Simultaneous Determination of Xanthine, its Methyl Derivatives Theophylline and Caffeine as well as its Metabolite Uric Acid
    Jesny, S.
    Kumar, K. Girish