First Alignment of the Complete CMS Silicon Tracking Detector

被引:0
|
作者
Lucaroni, A. [1 ]
机构
[1] Univ Perugia, I-06100 Perugia, Italy
关键词
D O I
10.1142/9789814307529_0139
中图分类号
P1 [天文学];
学科分类号
0704 ;
摘要
An overview of the CMS tracker alignment is presented. The overall alignment strategy is described with an emphasis on the tracker-based alignment with inputs from optical survey and the laser alignment system. The presented studies with the full CMS Silicon Tracker are based on several millions of reconstructed tracks from cosmic data taken during the commissioning runs with the detector in its final position. Finally a study of the effect of the alignment on tracking subset of cosmic muons, where the informants are expected to be consistent with the collision mode.
引用
收藏
页码:869 / 873
页数:5
相关论文
共 50 条
  • [41] Alignment of the ATLAS inner detector tracking system
    Gray, Heather M.
    JOURNAL OF INSTRUMENTATION, 2009, 4
  • [42] Alignment of the ATLAS Inner Detector Tracking System
    Kollar, Daniel
    17TH INTERNATIONAL CONFERENCE ON COMPUTING IN HIGH ENERGY AND NUCLEAR PHYSICS (CHEP09), 2010, 219
  • [43] Alignment of the ATLAS Inner Detector Tracking System
    Cortiana, Giorgio
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 1183 - 1188
  • [44] Alignment of the ATLAS Inner Detector Tracking System
    Cooper, B.
    ASTROPARTICLE, PARTICLE AND SPACE PHYSICS, DETECTORS AND MEDICAL PHYSICS APPLICATIONS, 2010, 5 : 824 - 828
  • [45] Role of the RPC Detector in the CMS Muon System for Tracking and Trigger
    Kim, Min Suk
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [46] Alignment of the CMS silicon tracker during commissioning with cosmic rays
    Chatrchyan, S.
    Khachatryan, V.
    Sirunyan, A. M.
    Adam, W.
    Arnold, B.
    Bergauer, H.
    Bergauer, T.
    Dragicevic, M.
    Eichberger, M.
    Eroe, J.
    Friedl, M.
    Fruehwirth, R.
    Ghete, V. M.
    Hammer, J.
    Haensel, S.
    Hoch, M.
    Hoermann, N.
    Hrubec, J.
    Jeitler, M.
    Kasieczka, G.
    Kastner, K.
    Krammer, M.
    Liko, D.
    de Abril, I. Magrans
    Mikulec, I.
    Mittermayr, F.
    Neuherz, B.
    Oberegger, M.
    Padrta, M.
    Pernicka, M.
    Rohringer, H.
    Schmid, S.
    Schoefbeck, R.
    Schreiner, T.
    Stark, R.
    Steininger, H.
    Strauss, J.
    Taurok, A.
    Teischinger, F.
    Themel, T.
    Uhl, D.
    Wagner, P.
    Waltenberger, W.
    Walzel, G.
    Widl, E.
    Wulz, C. -E.
    Chekhovsky, V.
    Dvornikov, O.
    Emeliantchik, I.
    Litomin, A.
    JOURNAL OF INSTRUMENTATION, 2010, 5
  • [47] Alignment of the CMS silicon tracker - and how to improve detectors in the future
    Kleinwort, Claus
    Meier, Frank
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 650 (01): : 240 - 244
  • [48] CMS silicon tracker alignment strategy with the Millepede II algorithm
    Flucke, G.
    Schleper, P.
    Steinbrueck, G.
    Stoye, M.
    JOURNAL OF INSTRUMENTATION, 2008, 3
  • [49] The commissioning and first results on the performance of the CMS Preshower Detector
    Ming, Chia Kuo
    XIV INTERNATIONAL CONFERENCE ON CALORIMETRY IN HIGH ENERGY PHYSICS (CALOR 2010), 2011, 293
  • [50] Alignment of CMS Structures Using Silicon Photo-Detectors
    Virto, A. L.
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 1113 - 1115