Reliability of high-resolution ultrasonography in the assessment of Achilles tendon enthesopathy in seronegative spondyloarthropathies

被引:77
|
作者
Filippucci, E. [1 ]
Aydin, S. Zehra [2 ]
Karadag, O. [3 ]
Salaffi, F. [1 ]
Gutierrez, M. [1 ]
Direskeneli, H. [2 ]
Grassi, W. [1 ]
机构
[1] Univ Politecn Marche, Dept Rheumatol, I-60035 Ancona, Italy
[2] Marmara Univ, Sch Med, Dept Rheumatol, Istanbul, Turkey
[3] Hacettepe Univ, Sch Med, Dept Rheumatol, Ankara, Turkey
关键词
POWER DOPPLER US; MUSCULOSKELETAL ULTRASOUND; ANKYLOSING-SPONDYLITIS; INTEROBSERVER RELIABILITY; PERIPHERAL ENTHESITIS; LOWER-LIMB; RHEUMATOLOGY; CLASSIFICATION; SYNOVITIS; AGREEMENT;
D O I
10.1136/ard.2008.096511
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: The present study was mainly aimed at investigating the interobserver and intraobserver reproducibility of ultrasound (US) results in the assessment of Achilles tendon enthesopathy in patients with seronegative spondyloarthropathies (SpA). Methods: A total of 28 patients with a diagnosis of SpA according to the European Spondyloarthropathy Study Group criteria were included. The patient female/male ratio was 1.8 (18/10), mean age was 42 (range 25-75) years and mean disease duration was 9 (range 1-35) years. Mean (SD) Bath Ankylosing Spondylitis Disease Activity Index (BASDAI) and Bath Ankylosing Spondylitis Functional Index (BASFI) scores were 32.4 (14.5) and 26.3 (9.2), respectively. Bilateral Achilles tendon US examinations were carried out independently by three investigators using a MyLab70 XVG (Esaote Biomedica, Genoa, Italy), equipped with a broadband 6-18 MHz linear probe. Each Achilles tendon was scanned for assessing the presence/absence of US findings indicative of enthesopathy according to the Outcome Measures in Rheumatoid Arthritis Clinical Trials (OMERACT) preliminary definition. The same findings were also scored on a 3-grade semiquantitative scoring system on which investigators reached a consensus prior to the study. Total additive scores per Achilles tendon were calculated. Results: Moderate to excellent interobserver and intraobserver agreements were found for most of the US findings indicative of enthesopathy. Similar results were obtained using semiquantitative assessments, with weighted kappa values estimating the interobserver and intraobserver agreements for soft tissue inflammation of 0.696 and 0.816, respectively and for tissue damage 0.711 and 0.901, respectively. Conclusion: US assessment of Achilles tendon enthesopathy in patients with SpA, using the OMERACT preliminary definition, was found to be reliable. Bone irregularity and entheseal hypoechogenicity were the most difficult abnormalities to reach agreement on.
引用
收藏
页码:1850 / 1855
页数:6
相关论文
共 50 条
  • [31] High-resolution ultrasound of the paratenon of the Achilles calcaneal tendon: anatomical study and description of the paratendinous injection technique
    Guenoun, Daphne
    Deniel, Cecile
    Champsaur, Pierre
    Pauly, Vanessa
    Moraux, Antoine
    Creze, Maud
    Corroller, Thomas Le
    SURGICAL AND RADIOLOGIC ANATOMY, 2024, 46 (09) : 1379 - 1386
  • [32] Utility of high-resolution ultrasonography and colour Doppler in the assessment of pigmented skin lesions
    Mandava, Anitha
    Konathan, Rajyalaxmi
    Neelala, Krishnaveni
    ULTRASOUND, 2012, 20 (03) : 155 - 160
  • [33] HIGH-SPEED HIGH-RESOLUTION ULTRASONOGRAPHY.
    Singh, S.
    Tandon, S.N.
    Gupta, H.M.
    Medical and Biological Engineering and Computing, 1987, 25 (05): : 585 - 589
  • [34] THE PREDICTIVE ACCURACY OF HIGH-RESOLUTION FETAL ULTRASONOGRAPHY
    CURRY, CJR
    SMITH, JC
    HOLLAND, JS
    WINTER, SC
    MARYMEE, K
    CLINICAL RESEARCH, 1985, 33 (01): : A117 - A117
  • [35] Nerve high-resolution ultrasonography in tangier disease
    Di Pasquale, Antonella
    Leonardi, Luca
    Fionda, Laura
    Vanoli, Fiammetta
    Garibaldi, Matted
    Inghilleri, Maurizio
    Ceccanti, Marco
    Cambieri, Chiara
    Onesti, Emanuela
    Antonini, Giovanni
    MUSCLE & NERVE, 2019, 59 (05) : 587 - 590
  • [36] Peritendinous lesions - The role of high-resolution ultrasonography
    Ho, CF
    Chiou, HJ
    Chou, YH
    Chang, CY
    CLINICAL IMAGING, 2003, 27 (04) : 239 - 250
  • [37] High-resolution ultrasonography in central serous chorioretinopathy
    Doro, D
    Visentin, S
    Maimone, PE
    Pilotto, E
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 2005, 139 (03) : 550 - 552
  • [38] HIGH-RESOLUTION ULTRASONOGRAPHY OF THE CARPAL-TUNNEL
    BUCHBERGER, W
    SCHON, G
    STRASSER, K
    JUNGWIRTH, W
    JOURNAL OF ULTRASOUND IN MEDICINE, 1991, 10 (10) : 531 - 537
  • [39] HIGH-RESOLUTION ULTRASONOGRAPHY OF THE TRANSVERSE CERVICAL NERVE
    Drlicek, Gregor
    Riegler, Georg
    Pivec, Christopher
    Mayer, Johannes A.
    Paraszti, Istvan
    Traxler, Hannes
    Wagner, Florian
    Moser, Veith
    Bodner, Gerd
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2020, 46 (07): : 1599 - 1607
  • [40] THE PREDICTIVE ACCURACY OF HIGH-RESOLUTION FETAL ULTRASONOGRAPHY
    CURRY, CJR
    CLINICAL RESEARCH, 1985, 33 (02): : A329 - A329