A drop tower for controlled impact testing of biological tissues

被引:40
|
作者
Burgin, Leanne V. [1 ]
Aspden, Richard M. [1 ]
机构
[1] Univ Aberdeen, Dept Orthopaed Surg, Aberdeen, Scotland
关键词
impact; articular cartilage; mechanical properties; drop tower; mechanical testing;
D O I
10.1016/j.medengphy.2006.06.002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Impact damage, in particular to tissues such as articular cartilage, is a recognised source of morbidity. To understand better the clinical outcomes, it is important to know the mechanics of the damage sustained and the biological response of cells to rapidly applied forces and subsequent tissue disruption. An instrumented drop tower has been designed to enable controlled impact loads to be applied to small samples of biological materials. Impact severity can be controlled by using impactors of different masses and various drop heights. Force and deceleration at impact are recorded at 50,000 samples s(-1) by a force transducer under the sample and an accelerometer on the impactor. Repeatability was tested on rubber washers and coefficients of variation were found to be better than 8% for dynamic stiffness, 3.4% for stress and 4.3% for strain. Initial tests on isolated biopsies of articular cartilage showed that at an initial strain rate of 916 s(-1), the peak dynamic modulus of human femoral head cartilage was 59 MPa, and for a bovine biopsy the initial strain rate and corresponding peak dynamic modulus were 3380 s(-1) and 130 Wa, respectively. The equipment described is capable of applying an impact load to small biopsies of tissue with a defined energy and velocity and measuring deformation and load at high rates of loading. (c) 2006 IPEM. Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:525 / 530
页数:6
相关论文
共 50 条
  • [1] Some recommendations for characterization of composite panels by means of drop tower impact testing
    Feraboli, Paolo
    JOURNAL OF AIRCRAFT, 2006, 43 (06): : 1710 - 1718
  • [2] THE INFLUENCE OF VELOCITY IN LOW-VELOCITY IMPACT TESTING OF COMPOSITES USING THE DROP-WEIGHT IMPACT TOWER
    RYDIN, RW
    BUSHMAN, MB
    KARBHARI, VM
    JOURNAL OF REINFORCED PLASTICS AND COMPOSITES, 1995, 14 (02) : 113 - 127
  • [3] Axial crush drop tower testing of hydroformed sections
    Mayer, Robert R.
    Webb, Scott
    Gusko, Ruth
    Williams, Bruce
    Worswick, Michael
    PROCEEDINGS OF THE ASME INTERNATIONAL MECHANICAL ENGINEERING CONGRESS AND EXPOSITION 2007, VOL 16: TRANSPORTATION SYSTEMS, 2008, : 327 - 340
  • [4] Design and Fabrication of a Drop Tower Testing Apparatus to Investigate the Impact Behavior of Spinal Motion Segments
    Kamal, Saeid
    Hashemi, Ata
    ARCHIVES OF BONE AND JOINT SURGERY-ABJS, 2020, 8 (06): : 682 - 688
  • [5] IMPACT TESTS OF UHSS STEEL WELDED JOINTS USING THE DROP - TOWER IMPACT DROP METHOD
    Dorozynski, J.
    Nowacki, J.
    Sajek, A.
    ADVANCES IN MATERIALS SCIENCE, 2019, 19 (03): : 19 - 31
  • [6] Drop Tower Adaptation for Medium Strain Rate Tensile Testing
    Perogamvros, N.
    Mitropoulos, T.
    Lampeas, G.
    EXPERIMENTAL MECHANICS, 2016, 56 (03) : 419 - 436
  • [7] Drop Tower Adaptation for Medium Strain Rate Tensile Testing
    N. Perogamvros
    T. Mitropoulos
    G. Lampeas
    Experimental Mechanics, 2016, 56 : 419 - 436
  • [8] Drop weight impact testing
    不详
    POWDER METALLURGY, 2002, 45 (03) : 191 - 191
  • [9] A drop tower method for high rate fracture toughness testing of polymers
    Horsfall, I
    Watson, CH
    Chilese, CG
    FRACTURE OF POLYMERS, COMPOSITES AND ADHESIVES II, 2003, 32 : 221 - 229
  • [10] Concrete Slabs under Impact Load - Drop Tower Experiments
    Hummeltenberg, Anja
    Beckmann, Birgit
    Weber, Tony
    Curbach, Manfred
    BETON- UND STAHLBETONBAU, 2011, 106 (03) : 160 - 168