摘要
Enhancements have been made in the development of a real-time optical pose measurement and tracking system that provides 3D position and orientation data for a single photon emission computed tomography (SPECT) imaging system for awake, unanesthetized, unrestrained small animals. Three optical cameras with infrared (IR) illumination view the head movements of an animal enclosed in a transparent burrow. Markers placed on the head provide landmark points for image segmentation. Strobed IR LED's are synchronized to the cameras and illuminate the markers to prevent motion blur for each set of images. The system using the three cameras automatically segments the markers, detects missing data, rejects false reflections, performs trinocular marker correspondence, and calculates the 3D pose of the animal's head. Improvements have been made in methods for segmentation, tracking, and 3D calculation to give higher speed and more accurate measurements during a scan. The optical hardware has been installed within a Siemens MicroCAT II small animal scanner at Johns Hopkins without requiring functional changes to the scanner operation. The system has undergone testing using both phantoms and live mice and has been characterized in terms of speed, accuracy, robustness, and reliability. Experimental data showing these motion tracking results are given.
引用
收藏
页码:3980 / +
页数:2
相关论文
共 50 条
  • [41] AN INFRARED MOTION DETECTOR SYSTEM FOR LOSSLESS REAL-TIME MONITORING OF ANIMAL PREFERENCE TESTS
    Pogany, A.
    Heszberger, J.
    Szurovecz, Zita
    Vincze, E.
    Szekely, T.
    [J]. ACTA BIOLOGICA HUNGARICA, 2014, 65 (04): : 385 - 395
  • [42] An Infrared Motion Detector System for Lossless Real-Time Monitoring of Animal Preference Tests
    Á. Pogány
    J. Heszberger
    Zita Szurovecz
    E. Vincze
    T. Székely
    [J]. Acta Biologica Hungarica, 2014, 65 : 385 - 395
  • [43] Dual-headed SPECT for awake animal brain imaging
    Lee, S.
    Kross, B.
    Weisenberger, A. G.
    McKisson, J.
    Goddard, J. S.
    Baba, J. S.
    Smith, M. F.
    [J]. 2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3250 - 3252
  • [44] Intrinsic Feature Pose Measurement for Awake Animal SPECT Imaging
    Goddard, J. S.
    Baba, J. S.
    Lee, S. J.
    Weisenberger, A. G.
    Stolin, A.
    McKisson, J.
    Smith, M. F.
    [J]. 2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2557 - +
  • [45] Detached multipinhole small animal SPECT device with real-time calibration
    DiFilippo, Frank P.
    Riffe, Matthew J.
    Harsch, Kelley M.
    McCabe, N. Patrick
    Heston, Warren D.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2006, 53 (05) : 2605 - 2612
  • [46] Real-Time Motion Tracking Detection System for a Spherical Pendulum Using a USB Camera
    Moon, Byung-Yoon
    Hong, Sung-Rak
    Ha, Manh-Tuan
    Kang, Chul-Goo
    [J]. TRANSACTIONS OF THE KOREAN SOCIETY OF MECHANICAL ENGINEERS A, 2016, 40 (09) : 807 - 813
  • [47] Human Limb Motion Real-time Tracking Based on CamShift for Intelligent Rehabilitation System
    Luo, Yuan
    Yang, Hongmei
    Hu, Zhangfang
    [J]. 2009 IEEE INTERNATIONAL CONFERENCE ON ROBOTICS AND BIOMIMETICS (ROBIO 2009), VOLS 1-4, 2009, : 343 - +
  • [48] A Regularized Real-Time Motion Tracking Algorithm Using Dynamic Programming for Ultrasonic Strain Imaging
    Jiang, Jingfeng
    Hall, Timothy J.
    [J]. 2006 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-5, PROCEEDINGS, 2006, : 606 - 609
  • [49] A hybrid real-time face tracking system
    Wang, C
    Brandstein, MS
    [J]. PROCEEDINGS OF THE 1998 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH AND SIGNAL PROCESSING, VOLS 1-6, 1998, : 3737 - 3740
  • [50] Real-Time Photoplethysmography Imaging System
    Rubins, U.
    Upmalis, V.
    Rubenis, O.
    Jakovels, D.
    Spigulis, J.
    [J]. 15TH NORDIC-BALTIC CONFERENCE ON BIOMEDICAL ENGINEERING AND MEDICAL PHYSICS (NBC 2011), 2011, 34 : 183 - 186