Analysis of Protein and Total Usable Nitrogen in Beer and Wine Using a Microwell Ninhydrin Assay

被引:88
|
作者
Abernathy, Daniel G. [1 ]
Spedding, Gary [2 ]
Starcher, Barry [1 ]
机构
[1] Univ Texas Hlth Sci Ctr Tyler, Tyler, TX USA
[2] Brewing & Distilling Analyt Serv LLC, Lexington, KY USA
关键词
beer; FAN; protein; wine; YAN; TRIKETOHYDRINDENE HYDRATE; ASSIMILABLE NITROGEN; MALT; LTP1; ANALOGS; ACID;
D O I
10.1002/j.2050-0416.2009.tb00356.x
中图分类号
TS2 [食品工业];
学科分类号
0832 ;
摘要
In this study we present a ninhydrin based microwell assay that can be utilized in place of the traditional Kjeldahl method for the determination of the protein content of beer or wine. In addition, the assay is ideal for the determination of free amino acids in beer (FAN), a term understood and used by brewers, and yeast assimilable nitrogen (YAN) used by enologists. The assay only measures alpha amino acids and ammonia so other nitrogen sources are not detected, resulting in a 30% reduction in total protein of a variety of beers compared to the Kjeldahl method, which measures nitro,,en from all sources. The results also showed that only 25% of the total "protein" in beer is actually derived from peptides larger than 3,500 Kd. Analysis of beer or wine with the microwell assay for total usable nitro-en was compared to the standard FAN and YAN methods and conditions were determined for maximal efficiency and precision. Superior results were obtained with low reaction volumes and a stable sodium acetate buffered ninhydrin reagent at pH 5.5. As an alternative. for use with cuvettes. a reduced volume FAN assay using the same pH 5.5 sodium acetate buffered ninhydrin reagent gave comparable results. The assay is economical, rapid, accurate and applicable to large numbers of samples.
引用
收藏
页码:122 / 127
页数:6
相关论文
共 50 条
  • [31] Analysis of total nitrogen and total phosphorus in soil using laser-induced breakdown spectroscopy
    鲁翠萍
    汪六三
    胡海瀛
    庄重
    汪玉冰
    王儒敬
    宋良图
    Chinese Optics Letters, 2013, 11 (05) : 79 - 82
  • [32] Quantitative analysis of ochratoxin A in wine and beer using solid phase extraction and high performance liquid chromatography-fluorescence detection
    Varelis, Peter
    Leong, Su-Lin L.
    Hocking, Ailsa
    Giannikopoulos, Georgina
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2006, 23 (12): : 1308 - 1315
  • [33] DETERMINATION OF PROTEIN AND TOTAL NITROGEN USING FP-228 IN COMPARISON WITH OTHER METHODS
    SIEGFRIED, R
    FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1989, 335 (05): : 489 - 492
  • [35] Total protein quantitation using the bicinchoninic acid assay and gradient elution moving boundary electrophoresis
    Kralj, Jason G.
    Munson, Matthew S.
    Ross, David
    ELECTROPHORESIS, 2014, 35 (12-13) : 1887 - 1892
  • [36] A simple method for the multi-elemental analysis of beer using total reflection X-ray fluorescence
    Gama, Ednilton M.
    Nascentes, Clesia C.
    Matos, Roberta P.
    Rodrigues, Gabrielle de C.
    Rodrigues, Guilherme D.
    TALANTA, 2017, 174 : 274 - 278
  • [37] Effects of Synchronization of Carbohydrate and Protein Supply in Total Mixed Ration with Korean Rice Wine Residue on Ruminal Fermentation, Nitrogen Metabolism and Microbial Protein Synthesis in Holstein Steers
    Piao, Min Yu
    Kim, Hyun J.
    Seo, J. K.
    Park, T. S.
    Yoon, J. S.
    Kim, K. H.
    Ha, Jong K.
    ASIAN-AUSTRALASIAN JOURNAL OF ANIMAL SCIENCES, 2012, 25 (11): : 1568 - 1574
  • [38] Multiresidue Analysis of Pesticides in Wine and Grape Using Gas Chromatography with Microelectron Capture and Nitrogen–Phosphorus Detection
    Magdalena Słowik-Borowiec
    Ewa Szpyrka
    Food Analytical Methods, 2018, 11 : 3516 - 3530
  • [39] Molecular Insights into the Aroma Difference between Beer and Wine: A Meta-Analysis-Based Sensory Study Using Concentration Leveling Tests
    Wang, Xingjie
    Frank, Stephanie
    Steinhaus, Martin
    JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2024, 72 (40) : 22250 - 22257
  • [40] Determination of free and total sulfites in wine using an automatic flow injection analysis system with voltammetric detection
    Goncalves, Luis Moreira
    Pacheco, Joao Grosso
    Magalhaes, Paulo Jorge
    Rodrigues, Jose Antonio
    Barros, Aquiles Araujo
    FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2010, 27 (02): : 175 - 180