In situ measurements of bioluminescence response of Gonyaulax spinifera to various mechanical stimuli

被引:6
|
作者
Vishal, C. R. [1 ]
Parvathi, A. [1 ]
Anil, P. [1 ]
Mohammed Iqbal, P. M. [1 ]
Muraleedharan, K. R. [1 ]
Abdul Azeez, S. [1 ]
Furtado, Camey M. [1 ]
机构
[1] CSIR Natl Inst Oceanog, Reg Ctr, Dr Salim Ali Rd,POB 1913, Kochi 682018, India
关键词
Dinoflagellate; Gonyaulax spinifera; Bioluminescence; Mechanical stimuli; Glowtracka; Cochin;
D O I
10.1007/s10452-021-09836-7
中图分类号
Q14 [生态学(生物生态学)];
学科分类号
071012 ; 0713 ;
摘要
A conspicuous bioluminescence during nighttime was reported in an aquaculture farm in the Cochin estuary due to Gonyaulax spinifera bloom on March 20, 2020. In situ measurements on bioluminescence was carried out during nighttime to quantify the response of G. spinifera to various mechanical stimuli. The bioluminescence intensity (BI) was measured using Glowtracka, an advanced single channel sensor, attached to a Conductivity-Temperature-Depth Profiler. In steady environment, without any external stimuli, the bioluminescence generated due to the movement of fishes and shrimps in the water column was not detected by the sensor. However, stimuli such as a hand splash, oar and swimming movements, and a mixer could generate measurable bioluminescence responses. An abundance of similar to 2.7 x 10(6) cells L-1 of G. spinifera with exceptionally high chlorophyll a of 25 mg m(-3) was recorded. The BI in response to hand splash was recorded as high as 1.6 x 10(11) photons cm(-2) s(-1). Similarly, BI of similar to 1-6 x 10(10) photons cm(-2) s(-1) with a cumulative bioluminescence of similar to 2.51 x 10(12) photons cm(-2) (for 35 s) was recorded when there is a mixer with a constant force of 494 N/800 rpm min(-1). The response of G. spinifera was spontaneous with no time lapse between application of stimuli and the bioluminescence response. Interestingly, in natural environment, application of stimulus for longer time periods (10 min) does not lower the bioluminescence intensity due to the replenishment of water thrusted in by the mixer from surrounding areas. We also demonstrated that the bioluminescence intensity decreases with increase in distance from the source of stimuli (mixer) (av. 1.84 x 10(10) photons cm(-2) s(-1) at 0.2 m to av. 0.05 x 10(10) photons cm(-2) s(-1) at 1 m). The BI was highest in the periphery of the turbulent wake generated by the stimuli (av. 3.1 x 10(10) photons cm(-2) s(-1)) compared to the center (av. 1.8 x 10(10) photons cm(-2) s(-1)). When the stimuli was applied vertically down, the BI decreased from 0.2 m (0.3 x 10(10) photons cm(-2) s(-1)) to 0.5 m (0.10 x 10(10) photons cm(-2) s(-1)). Our study demonstrates that the BI of G. spinifera increases with increase in mechanical stimuli and decreases with increase in distance from the stimuli.
引用
收藏
页码:437 / 451
页数:15
相关论文
共 50 条
  • [41] RESPONSE OF REPTILE CUTANEOUS MECHANORECEPTOR FIBERS TO GRADED MECHANICAL STIMULI
    SIMINOFF, R
    WOO, MY
    FELDMAN, PG
    KRUGER, L
    FEDERATION PROCEEDINGS, 1967, 26 (02) : 492 - &
  • [42] Stress Engineering: The Response of Phase Change Materials to Mechanical Stimuli
    Javanbakht, Mahdi
    Mohebbi, Sajjad
    Attariani, Hamed
    ACS APPLIED ELECTRONIC MATERIALS, 2023, 5 (06) : 3521 - 3530
  • [43] Passive cell membrane regulation in response to mechanical stimuli.
    Kosmalska, A.
    Casares Garcia, L.
    Elosegui-Artola, A.
    Thottacherry, J. J.
    Mayor, S.
    Arroyo, M.
    Navajas, D.
    Trepat, X.
    Gauthier, N.
    Roca-Cusachs, P.
    MOLECULAR BIOLOGY OF THE CELL, 2014, 25
  • [44] RESPONSE OF LARYNGEAL AFFERENT-FIBERS TO MECHANICAL AND CHEMICAL STIMULI
    BOUSHEY, HA
    RICHARDSON, PS
    WIDDICOMBE, JG
    WISE, JCM
    JOURNAL OF PHYSIOLOGY-LONDON, 1974, 240 (01): : 153 - 175
  • [45] Ipsilateral primary sensorimotor cortical response to mechanical tactile stimuli
    Hadoush, Hikmat
    Inoue, Ken
    Nakanishi, Kazuyoshi
    Kurumadani, Hiroshi
    Sunagawa, Toru
    Ochi, Mitsuo
    NEUROREPORT, 2010, 21 (02) : 108 - 113
  • [46] An investigation of human cortical bone's response to mechanical stimuli
    Wang, Yanan
    PROCEEDINGS OF THE 1ST INTERNATIONAL DESIGN TECHNOLOGY CONFERENCE, DESTECH2015, 2015, 20 : 60 - 65
  • [47] Joint biomarker response to mechanical stimuli in osteoarthritis - A scoping review
    Bjerre-Bastos, Jonathan J.
    Hamrouni, Nizar
    Henrotin, Yves
    Thudium, Christian S.
    Bihlet, Asger R.
    OSTEOARTHRITIS AND CARTILAGE OPEN, 2023, 5 (04):
  • [48] EFFECT OF SECRETIN ON GASTRIC ACID AND PEPSIN SECRETION IN RESPONSE TO VARIOUS STIMULI
    NAKAJIMA, S
    NAKAMURA, M
    MAGEE, DF
    AMERICAN JOURNAL OF PHYSIOLOGY, 1969, 216 (01): : 87 - &
  • [49] EFFECTS OF BODY WEIGHT AND DIABETES ON RESPONSE OF PLASMA INSULIN TO VARIOUS STIMULI
    JOHANSEN, K
    DIABETOLOGIA, 1970, 6 (06) : 654 - &
  • [50] RESPONSE OF SINGLE FUNGIFORM PAPILLAE OF FROG TONGUE TO VARIOUS CHEMICAL STIMULI
    PIETRA, P
    TAGLIETT.V
    MIRALDI, A
    BOLLETTINO DELLA SOCIETA ITALIANA DI BIOLOGIA SPERIMENTALE, 1970, 46 (20A): : 217 - &