Three-dimensional photoacoustic imaging of breast tissue phantoms

被引:1
|
作者
Manohar, S [1 ]
Kharine, A [1 ]
Steenbergen, W [1 ]
van Leeuwen, TG [1 ]
机构
[1] Univ Twente, Fac Appl Phys, Biophys Tech Grp, NL-7500 AE Enschede, Netherlands
关键词
photoacoustics; photoacoustic imaging; photoacoustic mammography; phantoms; poly(vinyl alcohol) gel;
D O I
10.1117/12.572028
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A laboratory prototype of a time-resolved photoacoustic mammograph, based on a parallel plate geometry is presented. Light is delivered from a Q-switched Nd:YAG laser using fibre-optic bundles which can be mechanically scanned across the surface of a phantom. The ultrasound signals produced by the photoacoustic effect are measured in a transmission mode, using a large-area ultrasound detector matrix. Signals from the matrix are acquired using fast digitizers. Various performance studies of the system are presented. A breast phantom of dimensions (150x120x60)mm was created based on poly(vinyl alcohol) (PVA) gel, which can be imparted with the average optical scattering properties of breast tissue by a simple process of freezing and thawing of an aqueous poly(vinyl alcohol) solution. The acoustic properties are also found to match those of breast tissue. Such a photoacoustic breast phantom was embedded with several tumour-simulating inhomogeneities. These inserts were also based on poly(vinyl alcohol) gels, appropriately dyed at the time of formation, to possess various optical absorption coefficients, between 2 and 7 times that of the background. Using the signals collected from regions-of-interest (ROI) in the volume of the phantom, three-dimensional images were obtained using a modified delay-and-sum beamforming algorithm. The results indicate that photoacoustics, as embodied in this instrument, has a potential for detecting tumours in the breast.
引用
收藏
页码:247 / 251
页数:5
相关论文
共 50 条
  • [31] A photoacoustic patch for three-dimensional imaging of hemoglobin and core temperature
    Gao, Xiaoxiang
    Chen, Xiangjun
    Hu, Hongjie
    Wang, Xinyu
    Yue, Wentong
    Mu, Jing
    Lou, Zhiyuan
    Zhang, Ruiqi
    Shi, Keren
    Chen, Xue
    Lin, Muyang
    Qi, Baiyan
    Zhou, Sai
    Lu, Chengchangfeng
    Gu, Yue
    Yang, Xinyi
    Ding, Hong
    Zhu, Yangzhi
    Huang, Hao
    Ma, Yuxiang
    Li, Mohan
    Mishra, Aditya
    Wang, Joseph
    Xu, Sheng
    NATURE COMMUNICATIONS, 2022, 13 (01)
  • [32] Analysis of three-dimensional photoacoustic imaging of a vascular tree in vitro
    Pilatou, MC
    Voogd, NJ
    de Mul, FFM
    Steenbergen, W
    van Adrichem, LNA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2003, 74 (10): : 4495 - 4499
  • [33] A photoacoustic patch for three-dimensional imaging of hemoglobin and core temperature
    Xiaoxiang Gao
    Xiangjun Chen
    Hongjie Hu
    Xinyu Wang
    Wentong Yue
    Jing Mu
    Zhiyuan Lou
    Ruiqi Zhang
    Keren Shi
    Xue Chen
    Muyang Lin
    Baiyan Qi
    Sai Zhou
    Chengchangfeng Lu
    Yue Gu
    Xinyi Yang
    Hong Ding
    Yangzhi Zhu
    Hao Huang
    Yuxiang Ma
    Mohan Li
    Aditya Mishra
    Joseph Wang
    Sheng Xu
    Nature Communications, 13
  • [34] Automated three-dimensional image registration for longitudinal photoacoustic imaging
    De Santi, Bruno
    Kim, Lucia
    Bulthuis, Rianne F. G.
    Lucka, Felix
    Manohar, Srirang
    JOURNAL OF BIOMEDICAL OPTICS, 2024, 29 : S11515
  • [35] Three-dimensional photoacoustic imaging technique based on acoustic lens
    Zhang Yu
    Tang Zhi-Lie
    Wu Yong-Bo
    Shu Gang
    ACTA PHYSICA SINICA, 2015, 64 (24)
  • [36] Simultaneous three-dimensional laser-ultrasound and photoacoustic imaging
    Wurzinger, Gerhild
    Nuster, Robert
    Schmitner, Nicole
    Gratt, Sibylle
    Paltauf, Guenther
    OPTO-ACOUSTIC METHODS AND APPLICATIONS, 2013, 8800
  • [37] Three-dimensional microwave tomography: Experimental imaging of phantoms and biological objects
    Semenov, SY
    Bulyshev, AE
    Souvorov, AE
    Nazarov, AG
    Sizov, YE
    Svenson, RH
    Posukh, VG
    Pavlovsky, A
    Repin, PN
    Tatsis, GP
    IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2000, 48 (06) : 1071 - 1074
  • [38] Three-dimensional phantoms for curvature correction in spatial frequency domain imaging
    Nguyen, Thu T. A.
    Le, Hanh N. D.
    Vo, Minh
    Wang, Zhaoyang
    Luu, Long
    Ramella-Roman, Jessica C.
    BIOMEDICAL OPTICS EXPRESS, 2012, 3 (06): : 1200 - 1214
  • [39] Three-Dimensional Photoacoustic Imaging Using a Two-Dimensional CMUT Array
    Vaithilingam, Srikant
    Ma, Te-Jen
    Furukawa, Yukio
    Wygant, Ira O.
    Zhuang, Xuefeng
    De la Zerda, Adam
    Oralkan, Oemer
    Kamaya, Aya
    Gambhir, Sanjiv S.
    Jeffrey, R. Brooke, Jr.
    Khuri-Yakub, Butrus T.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2009, 56 (11) : 2411 - 2419
  • [40] Three-dimensional Imaging of the Vasculature in Chicken Embryo by Combination of Ultrasonic and Photoacoustic Imaging
    Sato, Mika
    Izumi, Takuya
    Saijo, Yoshifumi
    Watanabe, Yuji
    Nakamura, Harukazu
    2013 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2013, : 1528 - +