ANFIS Based Hvdc Control and Fault Identification of HVDC Converter

被引:0
|
作者
Santhosh, S. [1 ]
机构
[1] Pannai Coll Engn & Technol, Dept Elect & Elect Engn, Sivagangai 630561, India
关键词
HVDC converter; ANFIS; ANFLBI; ANFLBC; controller; arithmetical replica; error identifier;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Identifying errors in HVDC converter and controlling HVDC system is presented in my paper. The easy and exact connoisseur system is neatly presented applying ANFIS (Acclimatized Neuro-Fuzzy Inference system. In both inversion and rectification mode faults are being identified when high voltage direct current with strong ac side and high voltage direct current with weak ac sides are available and incorporated fault identifier is developed replacing the old system of using individual error identifier in complete bridge converter. The conventionally used controller is PI which are in the existing HVDC systems is clearly operating good, they are prone to changes in system limits, holdups or other non-linearities in the system and endure from some limitations. ANFLBI and ANFLBC are the fuzzy logic supported error identifier and current controller respectively. ANFIS controller can function independently with arithmetical replica of the system and controlled input under interruption condition can be obtained without difficulty. My proposed system is easily combinable with error identifier, which can perk up active response of HYDC system. Quite a lot of digital replication results are obtainable to authenticate the process sketched in the paper.
引用
收藏
页码:186 / 190
页数:5
相关论文
共 50 条
  • [31] Study on Fault of Voltage Source Converter HVDC with MMC Technology
    Suherlan, Erik Jenjen
    Haroen, Yanuarsyah
    PROCEEDINGS OF THE 2015 10TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, 2015, : 1396 - 1401
  • [32] DC overvoltage control during loss of converter in multiterminal voltage-source converter-based HVDC (M-VSC-HVDC)
    Lu, WX
    Ooi, BT
    IEEE TRANSACTIONS ON POWER DELIVERY, 2003, 18 (03) : 915 - 920
  • [33] Transient fault identification method for bipolar short-circuit fault on MMC-HVDC overhead lines based on hybrid HVDC breaker
    Li, Botong
    Li, Chunbo
    Li, Bin
    Wen, Weijie
    Cui, Hanqing
    Su, Jiang
    HIGH VOLTAGE, 2021, 6 (05) : 881 - 893
  • [34] Control and protection scheme of HVDC system with self-commutated converter in system fault conditions
    Takasaki, M
    Gibo, N
    Takenaka, K
    Hayashi, T
    Konishi, H
    Tanaka, S
    Ito, H
    ELECTRICAL ENGINEERING IN JAPAN, 2000, 132 (02) : 6 - 18
  • [35] Experimental Validation of Autonomous Converter Control in a HVDC Grid
    Wang, Sheng
    Barker, C. D.
    Whitehouse, R. S.
    Liang, Jun
    2014 16TH EUROPEAN CONFERENCE ON POWER ELECTRONICS AND APPLICATIONS (EPE'14-ECCE EUROPE), 2014,
  • [36] Current control of a modular multilevel converter for HVDC applications
    Martinez-Rodrigo, Fernando
    de Pablo, Santiago
    Carlos Herrero-de Lucas, L.
    RENEWABLE ENERGY, 2015, 83 : 318 - 331
  • [37] Control and protection scheme of HVDC system with self-commutated converter in system fault conditions
    Takasaki, Masahiro, 2000, Scripta Technica Inc, New York, NY, United States (132):
  • [38] STABILITY OF CONVERTER CONTROL FOR MULTITERMINAL HVDC SYSTEMS.
    Padiyar, K.R.
    Sachchidanand
    IEEE transactions on power apparatus and systems, 1985, PAS-104 (03): : 690 - 696
  • [39] CONTROL AND PROTECTION OF HVDC SYSTEMS WITH DIODE VALVE CONVERTER
    MACHIDA, T
    ISHIKAWA, I
    OKADA, E
    KARASAWA, E
    ELECTRICAL ENGINEERING IN JAPAN, 1978, 98 (01) : 62 - 70
  • [40] DC Fault Identification in Multiterminal HVDC Systems Based on Reactor Voltage Gradient
    Hassan, Mehedi
    Hossain, M. Jahangir
    Shah, Rakibuzzaman
    IEEE ACCESS, 2021, 9 : 115855 - 115867