Step-by-Step Controller Design for LCL-Type Grid-Connected Inverter with Capacitor-Current-Feedback Active-Damping

被引:381
|
作者
Bao, Chenlei [1 ]
Ruan, Xinbo [1 ,2 ]
Wang, Xuehua [1 ]
Li, Weiwei [1 ]
Pan, Donghua [1 ]
Weng, Kailei [1 ]
机构
[1] Huazhong Univ Sci & Technol, State Key Lab Adv Electromagnet Engn & Technol, Wuhan 430074, Peoples R China
[2] Nanjing Univ Aeronaut & Astronaut, Coll Automat Engn, Aeropower Sci Tech Ctr, Nanjing 210016, Peoples R China
基金
中国国家自然科学基金;
关键词
Active damping; controller design; grid-connected inverter; LCL filter; single-phase; VOLTAGE-SOURCE CONVERTER; H-INFINITY CONTROL; PWM CONVERTERS; FILTER; SUPPRESSION; DISTORTION; STABILITY;
D O I
10.1109/TPEL.2013.2262378
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The injected grid current regulator and active damping of the LCL filter are essential to the control of LCL-type grid-connected inverters. Generally speaking, the current regulator guarantees the quality of the injected grid current, and the active damping suppresses the resonance peak caused by the LCL filter and makes it easier to stabilize the whole system. Based on the proportional-integral (PI) and proportional-resonant (PR) compensator together with capacitor-current-feedback active-damping which are widely used for their effectiveness and simple implementations, this paper proposes a simple step-by-step controller design method for the LCL-type grid-connected inverter. By carefully dealing with the interaction between the current regulator and active damping, the complete satisfactory regions of the controller parameters for meeting the system specifications are obtained, and from which the controller parameters can be easily picked out. Based on these satisfactory regions, it is more convenient and explicit to optimize the system performance. Besides, the insight of tuning the controller parameters from these satisfactory regions is also discussed. Simulation and experimental results verify the proposed step-by-step design method.
引用
收藏
页码:1239 / 1253
页数:15
相关论文
共 50 条
  • [31] Design Considerations of Digitally Controlled LCL-Filtered Inverter With Capacitor-Current-Feedback Active Damping
    Wang, Xuehua
    Bao, Chenlei
    Ruan, Xinbo
    Li, Weiwei
    Pan, Donghua
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2014, 2 (04) : 972 - 984
  • [32] A Step-by-Step Design Procedure of a Robust Control Design for Grid-Connected Inverter by LCL Filter in a Weak and Harmonically Distorted Grid
    Majid Hosseinpour
    Mahastan Asad
    Navid Rasekh
    Iranian Journal of Science and Technology, Transactions of Electrical Engineering, 2021, 45 : 843 - 859
  • [33] A Step-by-Step Design Procedure of a Robust Control Design for Grid-Connected Inverter by LCL Filter in a Weak and Harmonically Distorted Grid
    Hosseinpour, Majid
    Asad, Mahastan
    Rasekh, Navid
    IRANIAN JOURNAL OF SCIENCE AND TECHNOLOGY-TRANSACTIONS OF ELECTRICAL ENGINEERING, 2021, 45 (03) : 843 - 859
  • [34] Current Harmonic Analysis of Multisampled LCL-Type Grid-connected Inverter
    He, Shan
    Pan, Yiwei
    Zhou, Dao
    Wang, Xiongfei
    Blaabjerg, Frede
    2020 IEEE ENERGY CONVERSION CONGRESS AND EXPOSITION (ECCE), 2020, : 4329 - 4335
  • [35] An Active Capacitor Converter for Improving Robustness of the LCL-Type Grid-Connected Inverter against Grid Impedance Variation
    Zhou, Qingfeng
    Wang, Xuehua
    Ruan, Xinbo
    Teng, Yu
    Liu, Fuxin
    2017 THIRTY SECOND ANNUAL IEEE APPLIED POWER ELECTRONICS CONFERENCE AND EXPOSITION (APEC), 2017, : 3608 - 3613
  • [36] Grid-Voltage-Feedback Active Damping With Lead Compensation for LCL-Type Inverter Connected to Weak Grid
    Zeng, Chengbi
    Wang, Hanwen
    Li, Sudan
    Miao, Hong
    IEEE ACCESS, 2021, 9 (09): : 106813 - 106823
  • [37] Capacitor Voltage Full Feedback Scheme for LCL-Type Grid-Connected Inverter to Suppress Current Distortion Due to Grid Voltage Harmonics
    Zhang, Hao
    Ruan, Xinbo
    Lin, Zhiheng
    Wu, Liguo
    Ding, Yong
    Guo, Yong
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2021, 36 (03) : 2996 - 3006
  • [38] Robust Grid-Current-Feedback Resonance Suppression Method for LCL-Type Grid-Connected Inverter Connected to Weak Grid
    Zhou, Xiaoping
    Zhou, Leming
    Chen, Yandong
    Shuai, Zhikang
    Guerrero, Josep M.
    Luo, An
    Wu, Wenhua
    Yang, Ling
    IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS, 2018, 6 (04) : 2126 - 2137
  • [39] Direct Realization of Digital Differentiators in Discrete Domain for Active Damping of LCL-Type Grid-Connected Inverter
    Pan, Donghua
    Ruan, Xinbo
    Wang, Xuehua
    IEEE TRANSACTIONS ON POWER ELECTRONICS, 2018, 33 (10) : 8461 - 8473
  • [40] Unified Active Damping Strategy Based on Generalized Virtual Impedance in LCL-Type Grid-Connected Inverter
    Chen, Wei
    Zhang, Yan
    Tu, Yiming
    Guan, Yuanpeng
    Shen, Ke
    Liu, Jinjun
    IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, 2023, 70 (08) : 8129 - 8139