The diagnostic value of 11C-methionine PET in hyperparathyroidism with negative 99mTc-MIBI SPECT: a meta-analysis

被引:28
|
作者
Yuan, Leilei [1 ]
Liu, Jun [1 ]
Kan, Ying [1 ]
Yang, Jigang [1 ]
Wang, Xufu [2 ]
机构
[1] Capital Med Univ, Beijing Friendship Hosp, Dept Nucl Med, Beijing, Peoples R China
[2] Qingdao Univ, Coll Med, Affiliated Hosp, Dept Nucl Med, Qingdao, Peoples R China
基金
北京市自然科学基金;
关键词
11C-methionine; positron emission tomography (PET); hyperparathyroidism; 99mTc-MIBI; SPECT; ACCURATE PREOPERATIVE LOCALIZATION; POSITRON-EMISSION-TOMOGRAPHY; C-11-METHIONINE PET/CT; PARATHYROID ADENOMAS; SCINTIGRAPHY; NECK; MANAGEMENT; SURGERY; THERAPY;
D O I
10.1177/0284185116661878
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: 99mTc-sestamibi (MIBI) parathyroid SPECT is generally regarded as the best preoperative localizing method in patients with hyperparathyroidism (HPT). However, 99mTc-MIBI SPECT is false negative in approximately 25% of adenomas. 11C-methionine positron emission tomography (PET) has been used in HPT with negative 99mTc-MIBI SPECT scan results. Purpose: To systematically review and conduct a meta-analysis of published data on the performance of 11C-methionine PET in patients with HPT with negative 99mTc-MIBI SPECT. Material and Methods: A comprehensive review of the literature was performed. Pooled sensitivity and specificity of 11C-methionine PET in patients with HPT and a negative 99mTc-MIBI SPECT was calculated on a per-patient basis using receiver-operating characteristic (ROC) methodology. Results: Nine studies that met all inclusion and exclusion criteria were included into our meta-analysis, comprising a total sample size of 137 patients. Pooled sensitivity and specificity of 11C-methionine PET in patients with HPT with negative or inconclusive 99mTc-MIBI SPECT scans was 86% and 86%, respectively. The area under the ROC curve was 0.87. Conclusion: By merit of the high overall sensitivity, specificity, and accuracy, 11C-methionine PET can potentially complement the diagnostic workup of patients with HPT and negative or inconclusive 99mTc-MIBI SPECT. 11C-methionine PET appears to be a promising diagnostic modality in complicated cases with HPT.
引用
收藏
页码:558 / 564
页数:7
相关论文
共 50 条
  • [21] Diagnostic performance of 99mTc-MIBI scan in predicting the malignancy of thyroid nodules: a meta-analysis
    Treglia, Giorgio
    Caldarella, Carmelo
    Saggiorato, Enrico
    Ceriani, Luca
    Orlandi, Fabio
    Salvatori, Massimo
    Giovanella, Luca
    ENDOCRINE, 2013, 44 (01) : 70 - 78
  • [22] Diagnostic performance of 99mTc-MIBI scan in predicting the malignancy of thyroid nodules: a meta-analysis
    Giorgio Treglia
    Carmelo Caldarella
    Enrico Saggiorato
    Luca Ceriani
    Fabio Orlandi
    Massimo Salvatori
    Luca Giovanella
    Endocrine, 2013, 44 : 70 - 78
  • [23] Diagnostic performance of ultrasonography, dual-phase 99mTc-MIBI scintigraphy, early and delayed 99mTc-MIBI SPECT/CT in preoperative parathyroid gland localization in secondary hyperparathyroidism
    Zhang, Rongqin
    Zhang, Zhanwen
    Huang, Pinbo
    Li, Zhi
    Hu, Rui
    Zhang, Jie
    Qiu, Wanglin
    Hu, Ping
    BMC MEDICAL IMAGING, 2020, 20 (01)
  • [24] Diagnostic performance of ultrasonography, dual-phase 99mTc-MIBI scintigraphy, early and delayed 99mTc-MIBI SPECT/CT in preoperative parathyroid gland localization in secondary hyperparathyroidism
    Rongqin Zhang
    Zhanwen Zhang
    Pinbo Huang
    Zhi Li
    Rui Hu
    Jie Zhang
    Wanglin Qiu
    Ping Hu
    BMC Medical Imaging, 20
  • [25] Localization of parathyroid adenomas with 11C-Methionine PET/CT and 99mTc-sestamibi in primary hyperparathyroidism.
    Martinez-Rodriguez, I.
    Portilla-Quattrociocchi, H.
    Banzo, I.
    Quirce, R.
    De Arcocha, M.
    Jimenez-Bonilla, J.
    Rubio-Vassallo, A.
    Del Castillo Matos, R.
    Carril, J.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S164 - S164
  • [26] Comparison of 99mTc-sestamibi and 11C-methionine PET/CT in the localization of parathyroid adenomas in primary hyperparathyroidism
    Martinez-Rodriguez, I.
    Martinez-Amador, N.
    de Arcocha-Torres, M.
    Quirce, R.
    Ortega-Nava, F.
    Ibanez-Bravo, S.
    Lavado-Perez, C.
    Bravo-Ferrer, Z.
    Carril, J. M.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2014, 33 (02): : 93 - 98
  • [27] Improvement of 99MTc-MIBI in preoperative diagnostic of primary hyperparathyroidism using SPECT and iterative reconstruction algorithm.
    Moka, DC
    Eschner, W
    Dietlein, M
    Smolarz, K
    Voth, E
    Larena-Avellaneda, A
    Schicha, H
    JOURNAL OF NUCLEAR MEDICINE, 1999, 40 (05) : 50P - 50P
  • [28] Factors associated with negative 99mTc-MIBI scanning in patients with primary hyperparathyroidism
    Carral, F.
    Jimenez, A., I
    Tome, M.
    Alvarez, J.
    Diez, A.
    Partida, F.
    Ayala, C.
    REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2021, 40 (04): : 222 - 228
  • [29] Effect of calcium channel blockers on the sensitivity of preoperative 99MTC-MIBI SPECT for hyperparathyroidism
    Friedman, K
    Somervell, H
    Patel, P
    Melton, GB
    Garrett-Mayer, E
    Dackiw, APB
    Civelek, C
    Zeiger, MA
    SURGERY, 2004, 136 (06) : 1199 - 1204
  • [30] Analyze the causes of missed diagnosis with 99mTc-MIBI SPECT/CT for secondary hyperparathyroidism
    Jiang, Qin
    Yang, Ting
    Zou, Qiong
    Lei, Xu
    Ting, Ye
    Qian, Kang
    Ju, Jiao
    Zhang, Yong
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61