The diagnostic value of 11C-methionine PET in hyperparathyroidism with negative 99mTc-MIBI SPECT: a meta-analysis

被引:28
|
作者
Yuan, Leilei [1 ]
Liu, Jun [1 ]
Kan, Ying [1 ]
Yang, Jigang [1 ]
Wang, Xufu [2 ]
机构
[1] Capital Med Univ, Beijing Friendship Hosp, Dept Nucl Med, Beijing, Peoples R China
[2] Qingdao Univ, Coll Med, Affiliated Hosp, Dept Nucl Med, Qingdao, Peoples R China
基金
北京市自然科学基金;
关键词
11C-methionine; positron emission tomography (PET); hyperparathyroidism; 99mTc-MIBI; SPECT; ACCURATE PREOPERATIVE LOCALIZATION; POSITRON-EMISSION-TOMOGRAPHY; C-11-METHIONINE PET/CT; PARATHYROID ADENOMAS; SCINTIGRAPHY; NECK; MANAGEMENT; SURGERY; THERAPY;
D O I
10.1177/0284185116661878
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Background: 99mTc-sestamibi (MIBI) parathyroid SPECT is generally regarded as the best preoperative localizing method in patients with hyperparathyroidism (HPT). However, 99mTc-MIBI SPECT is false negative in approximately 25% of adenomas. 11C-methionine positron emission tomography (PET) has been used in HPT with negative 99mTc-MIBI SPECT scan results. Purpose: To systematically review and conduct a meta-analysis of published data on the performance of 11C-methionine PET in patients with HPT with negative 99mTc-MIBI SPECT. Material and Methods: A comprehensive review of the literature was performed. Pooled sensitivity and specificity of 11C-methionine PET in patients with HPT and a negative 99mTc-MIBI SPECT was calculated on a per-patient basis using receiver-operating characteristic (ROC) methodology. Results: Nine studies that met all inclusion and exclusion criteria were included into our meta-analysis, comprising a total sample size of 137 patients. Pooled sensitivity and specificity of 11C-methionine PET in patients with HPT with negative or inconclusive 99mTc-MIBI SPECT scans was 86% and 86%, respectively. The area under the ROC curve was 0.87. Conclusion: By merit of the high overall sensitivity, specificity, and accuracy, 11C-methionine PET can potentially complement the diagnostic workup of patients with HPT and negative or inconclusive 99mTc-MIBI SPECT. 11C-methionine PET appears to be a promising diagnostic modality in complicated cases with HPT.
引用
收藏
页码:558 / 564
页数:7
相关论文
共 50 条
  • [1] 99mTc-MIBI Or 11C-Methionine PET/CT In Primary Hyperparathyroidism With Inconclusive Preoperative Work-up?
    Maccora, D.
    Caldarella, C.
    Giordano, A.
    Bruno, I.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S821 - S822
  • [2] 99mTc-Mibi SPECT and 11C-Methionine PETCT imaging of patients with persistent primary hyperparathyreoidism
    Traub-Weidinger, T.
    Koelblinger, K.
    Duan, H.
    Riss, S.
    Scheuba, C.
    Koperek, O.
    Karanikas, G.
    Dudczak, R.
    Niederle, B.
    Hoffmann, M.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2011, 38 : S128 - S129
  • [3] 11C-methionine PET/CT for the evaluation of patients with recurrent or persistent secondary hyperparathyroidism after surgery and negative or inconclusive 99mTc-MIBI scintigraphy
    Damian, A.
    Quagliata, A.
    San Roman, S.
    Silvera, E.
    Rodriguez Taroco, M.
    Niell, N.
    Castro, R.
    Silvarino, R.
    Alonso, O.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2020, 47 (SUPPL 1) : S192 - S193
  • [4] 11C-Methionine PET/CT Imaging of 99mTc-MIBI-SPECT/CT-Negative Patients With Primary Hyperparathyroidism and Previous Neck Surgery
    Traub-Weidinger, Tatjana
    Mayerhoefer, Marius E.
    Koperek, Oskar
    Mitterhauser, Markus
    Duan, Heying
    Karanikas, Georgios
    Niederle, Bruno
    Hoffmann, Martha
    JOURNAL OF CLINICAL ENDOCRINOLOGY & METABOLISM, 2014, 99 (11): : 4199 - 4205
  • [5] 11C-methionine PET/CT after inconclusive 99mTc-MIBI-SPECT/CT for localisation of parathyroid adenomas in primary hyperparathyroidism
    Braeuning, U.
    Pfannenberg, C.
    Gallwitz, B.
    Teichmann, R.
    Mueller, M.
    Dittmann, H.
    Reimold, M.
    Bares, R.
    NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2015, 54 (01): : 26 - 30
  • [6] Comparative Analysis of Diagnostic Efficacy in Primary Hyperparathyroidism: A Comparison Analysis of 11C-Choline PET/CT, Neck Ultrasonography, 99mTc-MIBI Dual-Phase Planar Scintigraphy, and 99mTc-MIBI SPECT/CT Imaging
    Zhang, Zhining
    Zhao, Min
    Chen, Bin
    Cao, Yiming
    Gao, Shi
    JOURNAL OF CANCER, 2024, 15 (07): : 1863 - 1869
  • [7] Diagnostic performance of planar scintigraphy using 99mTc-MIBI in patients with secondary hyperparathyroidism: a meta-analysis
    Caldarella, Carmelo
    Treglia, Giorgio
    Pontecorvi, Alfredo
    Giordano, Alessandro
    ANNALS OF NUCLEAR MEDICINE, 2012, 26 (10) : 794 - 803
  • [8] Diagnostic performance of planar scintigraphy using 99mTc-MIBI in patients with secondary hyperparathyroidism: a meta-analysis
    Carmelo Caldarella
    Giorgio Treglia
    Alfredo Pontecorvi
    Alessandro Giordano
    Annals of Nuclear Medicine, 2012, 26 : 794 - 803
  • [9] SPECT/CT with 99mTc-MIBI in Diagnosing Primary Hyperparathyroidism
    Rumyantsev, P. O.
    Slaschuck, K.
    Degtyarev, M.
    Serzhenko, S.
    Trukhin, A.
    Sirota, Y.
    Nikiforovich, P.
    Sheremeta, M.
    Baranova, O.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2019, 46 (SUPPL 1) : S484 - S485
  • [10] C11-Choline PET/CT usefulness in patients with primary hyperparathyroidism and negative or inconclusive 99mTc-MIBI scan
    Gutierrez-Gonzalez, A.
    Cuenca-Vera, O.
    Martinez-Rodriguez, I.
    la Fuente, F. Gomez-De
    De Arcocha-Torres, M.
    Sanchez-Salmon, A.
    Martinez-Amador, N.
    Ruiz-Llama, S.
    Jimenez-Bonilla, J.
    Andres-Pacheco, J.
    Quirce, R.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2021, 48 (SUPPL 1) : S385 - S385