Teaching percutaneous renal biopsy using unfixed human cadavers

被引:6
|
作者
Oliver, Scott W. [1 ,2 ,3 ,6 ]
Patel, Rajan K. [2 ]
Ali, Khalid A. [4 ]
Geddes, Colin C. [2 ,5 ]
MacKinnon, Bruce [2 ,5 ]
机构
[1] Univ Glasgow, Sch Med, Glasgow G12 8QQ, Lanark, Scotland
[2] Queen Elizabeth Univ Hosp, Renal & Transplant Unit, Glasgow, Lanark, Scotland
[3] NHS Lanarkshire, Med Educ, Bothwell, Scotland
[4] Queen Elizabeth Univ Hosp, Dept Radiol, Glasgow, Lanark, Scotland
[5] Univ Glasgow, Clin Skills Anat Ctr, Glasgow G12 8QQ, Lanark, Scotland
[6] Wishaw Gen Hosp, Postgrad Off, Wishaw ML2 0DP, England
来源
BMC NEPHROLOGY | 2015年 / 16卷
关键词
Kidney biopsy; Nephrology; Haemorrhage; Cadaveric simulation; NATIVE KIDNEYS; ULTRASOUND; SIMULATION; COMPLICATIONS; SAFETY;
D O I
10.1186/s12882-015-0210-6
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Background: Percutaneous renal biopsy (PRB) is an important diagnostic procedure. Despite advances in its safety profile there remains a small but significant risk of bleeding complications. Traditionally, operators train to perform PRB through tutor instruction and directly supervised PRB attempts on real patients. We describe an approach to teaching operators to perform PRB using cadaveric simulation. Methods: We devised a full day course hosted in the Clinical Anatomy Skills Centre, with places for nine candidates. Course faculty consisted of two Consultant Nephrologists, two Nephrology trainees experienced in PRB, and one Radiologist. Classroom instruction included discussion of PRB indications, risk minimisation, and management of complications. Two faculty members acted as models for the demonstration of kidney localisation using real-time ultrasound scanning. PRB was demonstrated using a cadaveric model, and candidates then practised PRB using each cadaver model. Results: Written candidate feedback was universally positive. Faculty considered the cadaveric model a realistic representation of live patients, while the use of multiple cadavers introduced anatomical variation. Conclusions: Our model facilitates safe simulation of a high risk procedure. This might reduce serious harm associated with PRB and improve patient safety, benefiting trainee operators and patients alike.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] RENAL SCAN AS AN AID IN PERCUTANEOUS RENAL BIOPSY
    BAUM, S
    RABINOWITZ, P
    MALLOY, WA
    JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1966, 195 (11) : 913 - +
  • [22] THE SAFETY AND EFFICACY OF PERCUTANEOUS RENAL BIOPSY BY PHYSIAN-IN-TRAINING IN AN ACADEMIC TEACHING SETTING
    Alemu, B.
    Hamrahian, S.
    Csongradi, E.
    Juncos, L. A.
    Dreisbach, A.
    Fulop, T.
    JOURNAL OF INVESTIGATIVE MEDICINE, 2012, 60 (01) : 383 - 383
  • [23] Safety and Efficacy of Percutaneous Renal Biopsy by Physicians-in-Training in an Academic Teaching Setting
    Fueloep, Tibor
    Alemu, Bereket
    Dossabhoy, Neville R.
    Bain, Justin H.
    Pruett, David E.
    Szombathelyi, Anita
    Dreisbach, Albert W.
    Tapolyai, Mihaly
    SOUTHERN MEDICAL JOURNAL, 2014, 107 (08) : 520 - 525
  • [24] Utility of transjugular renal biopsy as an alternative to percutaneous biopsy
    Bolufer, Monica
    Garcia-Carro, Clara
    Agraz, Irene
    Diez Miranda, Iratxe
    Jaramillo, Juliana
    Arredondo, Karla
    Bury, Roxana
    Ramos, Natalia
    Azancot, Maria A.
    Gabaldon, Alejandra
    Perez Lafuente, Mercedes
    Espinel, Eugenia
    Segarra, Alfons
    Seron, Daniel
    Jose Soler, Maria
    NEFROLOGIA, 2020, 40 (06): : 634 - 639
  • [25] UTILITY OF TRANSYUGULAR RENAL BIOPSY AS AN ALTERNATIVE TO PERCUTANEOUS BIOPSY
    Bolufer, Monica
    Jose Soler, Maria
    Agraz, Irene
    Garcia-Carro, Clara
    Jaramillo, Juliana
    Arredondo, Karla
    Bury, Roxana
    Ramos, Natalia
    Antonia Azancot, M.
    Gabaldon, Alejandra
    Perez, Mercedes
    Espinel, Eugenia
    Seron, Daniel
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2019, 34
  • [26] PERCUTANEOUS PEDIATRIC RENAL BIOPSY - USE OF THE BIOPSY GUN
    POSTER, RB
    JONES, DB
    SPIRT, BA
    RADIOLOGY, 1990, 176 (03) : 725 - 727
  • [27] Using Porcine Cadavers as an Alternative to Human Cadavers for Teaching Minimally Invasive Spinal Fusion: Proof of Concept and Anatomical Comparison
    Abbasi, Hamid
    Abbasi, Ali
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2019, 11 (11)
  • [28] RADIORENOGRAM AFTER PERCUTANEOUS RENAL BIOPSY
    DAVIN, JC
    CHANTRAINE, JM
    ACTA PAEDIATRICA BELGICA, 1977, 30 (01) : 27 - 29
  • [29] PERCUTANEOUS RENAL BIOPSY IN COW AND HORSE
    OSBORNE, CA
    FAHNING, ML
    SCHULTZ, RH
    PERMAN, V
    JOURNAL OF THE AMERICAN VETERINARY MEDICAL ASSOCIATION, 1968, 153 (05) : 563 - &
  • [30] COMPLICATIONS AND RISKS OF PERCUTANEOUS RENAL BIOPSY
    Trajceska, Lada
    Selim, Gjulshen
    Busletik, Irena Rambabova
    Sikole, Aleksandar
    Severova, Galina
    Nikolov, Igor
    Dzekova, Pavlina Vidimliska
    Spasovski, Goce
    Ristovska, Vesna
    Grcevska, Ladislava
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2019, 34