Thulium Fiber Laser Lithotripsy using Small, Medium, and Large Muzzle Brake Fiber Optic Tips

被引:0
|
作者
Gonzalez, David A. [1 ]
Fried, Nathaniel M. [1 ,2 ,3 ]
机构
[1] Univ N Carolina, Dept Phys & Opt Sci, Charlotte, NC 28223 USA
[2] Carolinas Med Ctr, McKay Dept Urol, Charlotte, NC 28203 USA
[3] Johns Hopkins Univ, Brady Urol Inst, Baltimore, MD 21218 USA
关键词
ablation; laser; muzzle brake tip; retropulsion; thulium; HOLMIUM-YAG LASER; IN-VITRO INVESTIGATIONS; PULSE DURATION; STONE RETROPULSION; HO-YAG; FRAGMENTATION; PROPULSION; SETTINGS; WIDTH;
D O I
10.1117/12.2506784
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Previous Thulium fiber laser (TFL) studies using fiber optic muzzle brake tips reported reduced stone retropulsion and distal fiber tip degradation. This study compares muzzle brake tips of various dimensions using the TFL at 1908 and 1940 nm wavelengths in terms of stone phantom retropulsion displacement using a pendulum setup, needle hydrophone pressure transient measurements, and uric acid (UA) stone ablation rates. Low and high TFL pulse energies of 35 and 140 mJ, 500 mu s pulse duration, and pulse rates up to 300 Hz were used with 100- and 200-mu m-core optical fibers. "Small", "medium", and "large" muzzle brake tips dimensions measured 180/340, 360/560, and 550/710 mu m inner/outer diameter, respectively, with a porthole positioned 500 mu m from distal muzzle brake end. Pendulum displacement measured 50%, 200%, and 50% of bare trunk fibers for small, medium and large muzzle tips, respectively, in optimal configuration. Needle hydrophone pressures measured 300%, 20%, and 50% of bare trunk fiber for small, medium and large muzzle tips, respectively, in optimal configuration. Stone ablation rates at low pulse energy (35 mJ) were maintained for medium muzzle brake tips while small and large muzzle brake tips performed about 10 and 7.5 times worse than bare fibers. At high pulse energy (140 mJ), the large muzzle tip performed similar to a bare 200-mu m-core fiber with 100%, 50%, and 100% the displacement, pressure, and ablation rate. These studies show feasibility of modifying muzzle brake tip dimensions to obtain comparative ablation rates and minimal stone retropulsion for lithotripsy.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Comparison of 1908 and 1940 nm Wavelengths for Thulium Fiber Laser Lithotripsy
    Hardy, Luke A.
    Fried, Nathaniel M.
    THERAPEUTICS AND DIAGNOSTICS IN UROLOGY 2019, 2019, 10852
  • [32] Thulium-Doped Fiber Laser and Its Application in Urinary Lithotripsy
    Runyan Gu
    Zhilong Li
    Cheng Lei
    Sheng Li
    Du Wang
    Xinghuan Wang
    Journal of Medical and Biological Engineering, 2023, 43 : 351 - 361
  • [33] Mechanism of Lithotripsy by Superpulse Thulium Fiber Laser and Its Clinical Efficiency
    Lekarev, Vladimir
    Dymov, Alim
    Vinarov, Andrey
    Sorokin, Nikolay
    Minaev, Vladimir
    Minaev, Nikita
    Tsypina, Svetlana
    Yusupov, Vladimir
    APPLIED SCIENCES-BASEL, 2020, 10 (21): : 1 - 11
  • [34] Miniature Ureteroscope Tip Designs for use in Thulium Fiber Laser Lithotripsy
    Kennedy, Joshua D.
    Wilson, Christopher R.
    Irby, Pierce B.
    Fried, Nathaniel M.
    THERAPEUTICS AND DIAGNOSTICS IN UROLOGY: LASERS, ROBOTICS, MINIMALLY INVASIVE, AND ADVANCED BIOMEDICAL DEVICES, 2017, 10038
  • [35] Ureteroscopic lithotripsy of ureteric stone using thulium fiber laser in a pregnant patient, case report
    Alajmani, Lujin B.
    Rafi, Badr
    Banjar, Rowaa
    Alsenani, Faisal
    Hassan, Fadil
    Qashgry, Abdullah
    UROLOGY CASE REPORTS, 2023, 49
  • [36] Evaluating the learning curve for flexible ureteroscopic thulium fiber laser lithotripsy using CUSUM analysis
    Li, Zhilong
    Wu, Shaojie
    Tang, Xiaoyu
    Luo, Yongwen
    Wang, Du
    Liu, Tongzu
    Li, Sheng
    Wang, Xinghuan
    INTERNATIONAL JOURNAL OF SURGERY, 2025, 111 (03) : 2430 - 2438
  • [37] MOLDING OF LASER ENERGY BY SHAPED OPTIC FIBER TIPS
    WARD, H
    LASERS IN SURGERY AND MEDICINE, 1987, 7 (05) : 405 - 413
  • [38] THULIUM FIBER LASER RESULTS IN SHORTER OPERATING TIMES DURING URETEROSCOPY AND LASER LITHOTRIPSY
    Ryan, James R.
    Nguyen, Mitchell H.
    Linscott, Joshua A.
    Nowicki, Samuel W.
    Jumper, Brian M.
    Ingimarsson, Johann P.
    JOURNAL OF UROLOGY, 2021, 206 : E925 - E925
  • [39] A review of thulium-fiber laser in stone lithotripsy and soft tissue surgery
    Enikeev, Dmitry
    Traxer, Olivier
    Taratkin, Mark
    Okhunov, Zhamshid
    Shariat, Shahrokh
    CURRENT OPINION IN UROLOGY, 2020, 30 (06) : 853 - 860
  • [40] Thulium-fiber laser for lithotripsy: first clinical experience in percutaneous nephrolithotomy
    Enikeev, Dmitry
    Taratkin, Mark
    Klimov, Roman
    Alyaev, Yuriy
    Rapoport, Leonid
    Gazimiev, Magomed
    Korolev, Dmitry
    Ali, Stanislav
    Akopyan, Gagik
    Tsarichenko, Dmitry
    Markovina, Irina
    Ventimiglia, Eugenio
    Goryacheva, Evgenia
    Okhunov, Zhamshid
    Jefferson, Francis A.
    Glybochko, Petr
    Traxer, Olivier
    WORLD JOURNAL OF UROLOGY, 2020, 38 (12) : 3069 - 3074