A comparison between two different dried blood substrates in determination of psychoactive substances in postmortem samples

被引:16
|
作者
Moretti, Matteo [1 ]
Manfredi, Alessandro [3 ]
Freni, Francesca [1 ]
Previdere, Carlo [1 ]
Osculati, Antonio Marco Maria [1 ,2 ]
Grignani, Pierangela [1 ]
Tronconi, Livio [1 ,2 ]
Carelli, Claudia [1 ]
Vignali, Claudia [1 ]
Morini, Luca [1 ]
机构
[1] Univ Pavia, Dept Publ Hlth Expt & Forens Med, Via Forlanini 12, Pavia, Italy
[2] IRCCS Fdn Mondino, Legal Med Operat Unit, Via Mondino 2, I-27100 Pavia, PV, Italy
[3] Univ Trieste, Dept Med Surg & Hlth, Piazzale Europa 1, Trieste, Italy
关键词
Flinders Technology Associates card; Dried blood spots; Postmortem; Psychoactive substances;
D O I
10.1007/s11419-020-00567-2
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
Purpose Whatman (TM) 903 cards represent a valid type of support for collection, storage, and analysis of dried blood spots (DBS). Whatman (TM) FTA (Flinders Technology Associates) are a type of cards soaked in chemicals that cause denaturation of proteins, while preserving DNA and ensuring the safe handling of DBS; to date, these cards are still rarely employed in forensic toxicology. The aim of this study was to analyze several psychoactive substances on not-dried blood on the two different cards and to compare the qualitative and quantitative results. Methods Twenty cardiac postmortem blood samples were collected and deposed on Whatman (TM) 903 and Whatman (TM) FTA cards. Spots and not-dried blood were analyzed following our validated and previously published liquid chromatography-mass spectrometry methods. Results We were able to identify: eight drugs of abuse and their metabolites (15 cases), five benzodiazepines and their metabolites (3 cases), six antidepressants (6 cases) and two antipsychotics (3 cases). We observed a perfect qualitative correspondence and a general good quantitative correlation between data obtained from not-dried blood and the two different DBS cards, except for alprazolam, diazepam, desmethyldiazepam, fluoxetine and sertraline, that showed a lower concentration on FTA. Additional experiments suggest that the chemicals, adsorbed on FTA, are not the cause of the loss of signal observed for the substances previously mentioned and that methanol should be preferred as extraction solvent. Conclusions This study proved that FTA cards are a good and a hazard-free alternative sample storage method for analysis of several psychoactive substances in postmortem blood.
引用
收藏
页码:385 / 393
页数:9
相关论文
共 50 条
  • [41] Measurement and Comparison of Organic Compound Concentrations in Plasma, Whole Blood, and Dried Blood Spot Samples
    Batterman, Stuart A.
    Chernyak, Sergey
    Su, Feng-Chiao
    FRONTIERS IN GENETICS, 2016, 7
  • [42] Determination of Cross-Reactivity of Novel Psychoactive Substances with Drug Screen Immunoassays Kits in Whole Blood
    Mastrovito, Rebecca
    Trail, Cherie
    Lino, Marjola
    Cervantes, Abigail
    Chan-Hosokawa, Aya
    Strathmann, Fredrick
    Logan, Barry
    JOURNAL OF ANALYTICAL TOXICOLOGY, 2022, 46 (07) : 726 - 731
  • [43] Comparison of serum cell-free DNA between postmortem and living samples
    Fujihara, Junko
    Takinami, Yoshikazu
    Kawai, Yasuyuki
    Kimura-Kataoka, Kaori
    Takeshita, Haruo
    CLINICA CHIMICA ACTA, 2021, 519 : 255 - 259
  • [44] Incurred sample reanalysis comparison of dried blood spots and plasma samples on the measurement of lopinavir in clinical samples
    Meesters, Roland J. W.
    Hooff, Gero P.
    Gruters, Rob
    van Kampen, Jeroen J. A.
    Luider, Theo M.
    BIOANALYSIS, 2012, 4 (03) : 237 - 240
  • [45] Determination of perampanel in plasma samples: comparison and cross-validation between two HPLC methods utilizing two different detectors: spectrofluorimetric and mass spectrometry
    D'Urso, Annachiara
    Fontana, Federica
    Gabrieletto, Ivana
    Gilardoni, Francesca
    De Riva, Valentina
    Contarato, Giorgia
    Ranzato, Federica
    Galloni, Elisabetta
    de Grazia, Ugo
    BIOCHIMICA CLINICA, 2018, 42 (03) : 217 - 224
  • [46] The comparison between the rays produced by different radioactive substances
    Blanquies
    COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES, 1909, 148 : 1753 - 1756
  • [47] Correlation between ranitidine quantification measured in Dried Blood Spots and Plasma paediatric samples using different detection techniques
    Yakkundi, S.
    Millership, J. S.
    Collier, P. C.
    McElnay, J.
    JOURNAL OF PHARMACY AND PHARMACOLOGY, 2010, 62 (10) : 1204 - 1205
  • [48] Comparison of metabolomic information between dried blood spot and serum
    Monteiro, J.
    Lefevre, A.
    Dufour-Rainfray, D.
    Dupuy, C.
    Oury, A.
    Blasco, H.
    Galineau, L.
    Bertrand-Michel, J.
    Pujos-Guillot, E.
    Castelli, F. A.
    Nadal-Desbarats, L.
    Emond, P.
    FEBS OPEN BIO, 2024, 14 : 116 - 116
  • [49] Development and validation of a dried blood spot–HPLC assay for the determination of metronidazole in neonatal whole blood samples
    Maysa Faisal Suyagh
    Godwill Iheagwaram
    Prashant Laxman Kole
    Jeff Millership
    Paul Collier
    Henry Halliday
    James C. McElnay
    Analytical and Bioanalytical Chemistry, 2010, 397 : 687 - 693
  • [50] GLOMERULAR FILTRATION RATE (GFR) MEASURED BY IOHEXOL CLEARANCE IN CHILDREN; A COMPARISON BETWEEN VENOUS SAMPLES AND DRIED BLOOD SPOTS
    Salvador, Catrin Lytomt
    Tondel, Camilla
    Morkrid, Lars
    Bjerre, Anna
    Bolann, Bjorn
    Brun, Atle
    Brackman, Damien
    Bergan, Stein
    PEDIATRIC NEPHROLOGY, 2013, 28 (08) : 1653 - 1654