A comparison between two different dried blood substrates in determination of psychoactive substances in postmortem samples

被引:16
|
作者
Moretti, Matteo [1 ]
Manfredi, Alessandro [3 ]
Freni, Francesca [1 ]
Previdere, Carlo [1 ]
Osculati, Antonio Marco Maria [1 ,2 ]
Grignani, Pierangela [1 ]
Tronconi, Livio [1 ,2 ]
Carelli, Claudia [1 ]
Vignali, Claudia [1 ]
Morini, Luca [1 ]
机构
[1] Univ Pavia, Dept Publ Hlth Expt & Forens Med, Via Forlanini 12, Pavia, Italy
[2] IRCCS Fdn Mondino, Legal Med Operat Unit, Via Mondino 2, I-27100 Pavia, PV, Italy
[3] Univ Trieste, Dept Med Surg & Hlth, Piazzale Europa 1, Trieste, Italy
关键词
Flinders Technology Associates card; Dried blood spots; Postmortem; Psychoactive substances;
D O I
10.1007/s11419-020-00567-2
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
Purpose Whatman (TM) 903 cards represent a valid type of support for collection, storage, and analysis of dried blood spots (DBS). Whatman (TM) FTA (Flinders Technology Associates) are a type of cards soaked in chemicals that cause denaturation of proteins, while preserving DNA and ensuring the safe handling of DBS; to date, these cards are still rarely employed in forensic toxicology. The aim of this study was to analyze several psychoactive substances on not-dried blood on the two different cards and to compare the qualitative and quantitative results. Methods Twenty cardiac postmortem blood samples were collected and deposed on Whatman (TM) 903 and Whatman (TM) FTA cards. Spots and not-dried blood were analyzed following our validated and previously published liquid chromatography-mass spectrometry methods. Results We were able to identify: eight drugs of abuse and their metabolites (15 cases), five benzodiazepines and their metabolites (3 cases), six antidepressants (6 cases) and two antipsychotics (3 cases). We observed a perfect qualitative correspondence and a general good quantitative correlation between data obtained from not-dried blood and the two different DBS cards, except for alprazolam, diazepam, desmethyldiazepam, fluoxetine and sertraline, that showed a lower concentration on FTA. Additional experiments suggest that the chemicals, adsorbed on FTA, are not the cause of the loss of signal observed for the substances previously mentioned and that methanol should be preferred as extraction solvent. Conclusions This study proved that FTA cards are a good and a hazard-free alternative sample storage method for analysis of several psychoactive substances in postmortem blood.
引用
收藏
页码:385 / 393
页数:9
相关论文
共 50 条
  • [1] A comparison between two different dried blood substrates in determination of psychoactive substances in postmortem samples
    Matteo Moretti
    Alessandro Manfredi
    Francesca Freni
    Carlo Previderé
    Antonio Marco Maria Osculati
    Pierangela Grignani
    Livio Tronconi
    Claudia Carelli
    Claudia Vignali
    Luca Morini
    Forensic Toxicology, 2021, 39 : 385 - 393
  • [2] Psychoactive substances in suicides - Comparison of toxicologic findings in two samples
    Dhossche, DM
    Rich, CL
    Isacsson, G
    AMERICAN JOURNAL OF FORENSIC MEDICINE AND PATHOLOGY, 2001, 22 (03): : 239 - 243
  • [3] Chitotriosidase determination in plasma and in dried blood spots:: A comparison using two different substrates in a microplate assay
    Rodrigues, M. D. B.
    Oliveira, A. C.
    Mueller, K. B.
    Martins, A. M.
    D'Almeida, V
    JOURNAL OF INHERITED METABOLIC DISEASE, 2008, 31 : 96 - 96
  • [4] Chitotriosidase determination in plasma and in dried blood spots: A comparison using two different substrates in a microplate assay
    Rodrigues, Mayra D. B.
    de Oliveira, Allan C.
    Mueller, Karen B.
    Martins, Ana Maria
    D'Almeida, Vania
    CLINICA CHIMICA ACTA, 2009, 406 (1-2) : 86 - 88
  • [5] Determination of new psychoactive substances and other drugs in postmortem blood and urine by UHPLC–MS/MS: method validation and analysis of forensic samples
    Ettore Ferrari Júnior
    Eloisa Dutra Caldas
    Forensic Toxicology, 2022, 40 : 88 - 101
  • [6] Determination of new psychoactive substances and other drugs in postmortem blood and urine by UHPLC-MS/MS: method validation and analysis of forensic samples
    Ferrari Junior, Ettore
    Caldas, Eloisa Dutra
    FORENSIC TOXICOLOGY, 2022, 40 (01) : 88 - 101
  • [7] Newborn Screening for Congenital Hypothyroidism-Clinical Evaluation and Comparison of Two Different Test Kits for the Determination of TSH in Dried Blood Samples on Two Different Platforms
    Fingerhut, Ralph
    INTERNATIONAL JOURNAL OF NEONATAL SCREENING, 2021, 7 (03)
  • [8] Use of psychoactive substances in two samples of children between 10 and 12 years old
    Slapak, S
    Grigoravicius, MJ
    INTERNATIONAL JOURNAL OF PSYCHOLOGY, 2004, 39 (5-6) : 450 - 450
  • [9] Determination of 19 Psychoactive Substances in Premortem and Postmortem Whole Blood Samples Using Ultra-High-Performance Liquid Chromatography-Tandem Mass Spectrometry
    Karampela, Sevasti
    Smith, Jessica
    Panderi, Irene
    SEPARATIONS, 2021, 8 (06)
  • [10] Comparison of Different Analytical Methods for the Determination of Carbon Monoxide in Postmortem Blood
    Zanaboni, Moira
    Roda, Gabriella
    Arnoldi, Sebastiano
    Casagni, Eleonora
    Gambaro, Veniero
    Dei Cas, Michele
    JOURNAL OF FORENSIC SCIENCES, 2020, 65 (02) : 636 - 640