Unit commitment in a hybrid diesel/wind/pumped-storage isolated power system considering the net demand intra-hourly variability

被引:9
|
作者
Fernandez-Munoz, Daniel [1 ]
Perez-Diaz, Juan I. [1 ]
机构
[1] Univ Politecn Madrid UPM, Dept Hydraul Energy & Environm Engn, ETSICCP, C Prof Aranguren S-N, Madrid 28040, Spain
关键词
WIND POWER; STOCHASTIC OPTIMIZATION; ENERGY; IMPACT; PLANT;
D O I
10.1049/rpg2.12003
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
This paper presents a novel two-stage stochastic mixed-integer linear programming model for the generation scheduling of a hybrid diesel/wind/pumped-storage power system that considers the intra-hourly net demand variability during the first stage. The model aims to minimise the scheduling cost, calculates the power system storage opportunity cost and considers that the start-up cost of thermal units depends on the time passed since the previous shutdown in a detailed manner for the first stage (i.e. using integer variables) and in an approximate manner (relaxing the integrality constraints) for the second stage. To increase the model's computational efficiency, a solution approach based on the Benders decomposition technique is applied. The model is implemented in the real power system of El Hierro island, an isolated hybrid diesel/wind/pumped-storage power system with a closed-loop pumped-storage plant and high wind power installed capacity. The schedules provided by the proposed model are compared to the ones provided by a similar model that does not consider the intra-hourly net demand variability, resulting in generation schedules with a significantly lower wind energy curtailment. The results demonstrate the importance of considering the intra-hourly net demand variability in order to integrate more wind energy at a moderate extra cost.
引用
收藏
页码:30 / 42
页数:13
相关论文
共 30 条
  • [21] Analysis of energy variability and costs for offshore wind and hybrid power unit with equivalent energy storage system
    Gao, Qiang
    Yuan, Rui
    Ertugrul, Nesimi
    Ding, Boyin
    Hayward, Jennifer A.
    Li, Ye
    APPLIED ENERGY, 2023, 342
  • [22] Multi-Objective Optimal Scheduling of Power System Considering the Coordinated Operation of Photovoltaic-Wind-Pumped Storage Hybrid Power
    Ma, Rui
    Li, Xuan
    Wu, Zhaoyu
    Zhang, Qiang
    2015 5TH INTERNATIONAL CONFERENCE ON ELECTRIC UTILITY DEREGULATION AND RESTRUCTURING AND POWER TECHNOLOGIES (DRPT 2015), 2015, : 693 - 698
  • [23] Dual mode linguistic hedge fuzzy logic controller for an isolated wind-diesel hybrid power system with superconducting magnetic energy storage unit
    Ansari, M. Md. Thameem
    Velusami, S.
    ENERGY CONVERSION AND MANAGEMENT, 2010, 51 (01) : 169 - 181
  • [24] Fault-tolerant controller design for a master generation unit in an isolated hybrid wind-diesel power system
    Vargas-Martinez, Adriana
    Ismael Minchala-Avila, Luis
    Zhang, Youmin
    Eduardo Garza-Castanon, Luis
    Acosta-Santana, Patricia
    INTERNATIONAL JOURNAL OF ROBUST AND NONLINEAR CONTROL, 2015, 25 (05) : 761 - 772
  • [25] Design of Dual Mode Linguistic Hedge Fuzzy Logic Controller for an Isolated Wind-Diesel Hybrid Power System with Lossy Magnetic Energy Storage Unit
    Ansari, M. Md. Thameem
    Velusami, S.
    WIND ENGINEERING, 2009, 33 (06) : 607 - 629
  • [26] DMLHFLC (Dual mode linguistic hedge fuzzy logic controller) for an isolated wind-diesel hybrid power system with BES (battery energy storage) unit
    Ansari, M. Mohamed Thameem
    Velusami, S.
    ENERGY, 2010, 35 (09) : 3827 - 3837
  • [27] A Mixed-Integer Convex Programming Algorithm for Security-Constrained Unit Commitment of Power System with 110-kV Network and Pumped-Storage Hydro Units
    Lin, Shunjiang
    Fan, Guansheng
    Lu, Yuan
    Liu, Mingbo
    Lu, Yi
    Li, Qifeng
    ENERGIES, 2019, 12 (19)
  • [28] DYNAMICS AND STABILITY OF WIND AND DIESEL TURBINE GENERATORS WITH SUPERCONDUCTING MAGNETIC ENERGY-STORAGE UNIT ON AN ISOLATED POWER-SYSTEM
    TRIPATHY, SC
    KALANTAR, M
    BALASUBRAMANIAN, R
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 1991, 6 (04) : 579 - 585
  • [29] Dynamic performance assessment of an isolated wind-diesel power system with superconducting magnetic energy storage unit under turbulent wind and load disturbances
    Mufti, MD
    Balasubramanian, R
    Tripathy, SC
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2002, 26 (03) : 185 - 201
  • [30] A coordinated operating control strategy for hybrid isolated microgrid including wind power, photovoltaic system, diesel generator, and battery storage
    Key Laboratory of Smart Grid of Ministry of Education, Tianjin University, Tianjin 300072, China
    不详
    不详
    Dianli Xitong Zidonghue, 2012, 15 (19-24):