A laboratory study of the scouting ability of two reciprocating glide path instruments in mesial root canals of extracted mandibular molars

被引:4
|
作者
Pereira, R. P. [1 ]
Alcalde, M. P. [1 ]
Duarte, M. A. H. [1 ]
Vivan, R. R. [1 ]
Bueno, C. E. S. [2 ]
Duque, J. A. [1 ]
Calefi, P. H. S. [1 ]
Bramante, C. M. [1 ]
机构
[1] Univ Sao Paulo, Bauru Sch Dent, Dept Operat Dent Endodont & Dent Mat, Bauru, SP, Brazil
[2] Sao Leopoldo Mand Dent Res Ctr, Dept Endodont, Campinas, Brazil
关键词
glide path; nickel‐ titanium; root canal preparation; torsional resistance;
D O I
10.1111/iej.13492
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Aim To evaluate in a laboratory setting the performance of two reciprocating glide path systems, WaveOne Gold Glider (WO) and R-Pilot (RP), to create a glide path in mesial root canals of mandibular molars and to assess the torsional resistance of instruments after performing the glide path. Methodology A total of 60 mesial root canals of extracted human mandibular molars were divided into two groups (n = 30) according to the glide path system to be used. The data from the volume of each canal, acquired by microcomputed tomography (micro-CT), were validated statistically for the anatomical pairing of the groups. Preparation time, frequency in gaining apical patency, plastic deformation rate of instruments, and canal transportation and centring ability were recorded and compared statistically. The torsional fatigue of the instruments after use was also evaluated. Data were analysed using Fisher's exact test and Mann-Whitney U-test with a 5% significance level. Results No significant differences were found between groups regarding the time required to perform the glide path, the frequency distributions of the canals classified as patent and the instruments with plastic deformation after use (P > 0.05). No significant differences were found between groups regarding the degree of canal transportation and centring ability at the cervical, middle and apical thirds (P > 0.05). The RP groups had significantly greater maximum torsional strength values compared with the WO groups (P < 0.05). The used WO group had greater angular deflection to fracture when compared to the new WO group (P < 0.05). A significant difference was also found in the percentage of loss of angular deflection in a comparison of the WO group with the RP group (P < 0.05). Conclusions The WO and RP instruments performed the same in terms of preparation time, plastic deformation, gaining apical patency, degree of canal transportation and centring ability. The RP instruments had greater torsional strength, less angular deflection and lower percentage of loss in angular deflection than the WO. The used WO group had the greatest angular deflection values.
引用
收藏
页码:1166 / 1174
页数:9
相关论文
共 27 条
  • [21] Comparison of canal transportation and centering ability of manual K-files and reciprocating files in glide path preparation: a micro-computed tomography study of constricted canals
    Liu, Jing-Yi
    Zhou, Zhi-Xiong
    Tseng, Wei-Ju
    Karabucak, Bekir
    BMC ORAL HEALTH, 2021, 21 (01)
  • [22] Comparison of canal transportation and centering ability of manual K-files and reciprocating files in glide path preparation: a micro-computed tomography study of constricted canals
    Jing-Yi Liu
    Zhi-Xiong Zhou
    Wei-Ju Tseng
    Bekir Karabucak
    BMC Oral Health, 21
  • [23] Can size 20, .04 taper rotary files reproducibly create a glide path for the self-adjusting file? An ex vivo study in MB canals of mandibular molars
    Kfir, A.
    Goldberger, T.
    Koren, T.
    Pawar, A. M.
    Abramovitz, I.
    INTERNATIONAL ENDODONTIC JOURNAL, 2016, 49 (03) : 301 - 306
  • [24] Evaluation of Two Shaping Systems and Two Ultrasonic Irrigation Devices in Removing Root Canal Filling Material from Mesial Roots of Mandibular Molars: A Micro CT Study
    Kaloustian, Marc Krikor
    Nehme, Walid
    El Hachem, Claire
    Zogheib, Carla
    Ghosn, Nabil
    Michetti, Jerome
    Naaman, Alfred
    Diemer, Franck
    DENTISTRY JOURNAL, 2019, 7 (01)
  • [25] Comparative Evaluation of Root Canal Transportation and Centering Ability in Curved Mesiobuccal Canals of Mandibular First Molars after Instrumentation with Different File Systems-An In vitro Study
    Langaliya, Akshayraj
    Kothari, Anjali
    Buch, Aastha
    Dave, Riya
    Shah, Jinali
    Shah, Nishtha
    JOURNAL OF PHARMACY AND BIOALLIED SCIENCES, 2023, 15 : S1211 - S1214
  • [26] Comparative study on the shaping ability and cleaning efficiency of rotary Mtwo instruments.: Part 2.: Cleaning effectiveness and shaping ability in severely curved root canals of extracted teeth
    Schäfer, E
    Erler, M
    Dammaschke, T
    INTERNATIONAL ENDODONTIC JOURNAL, 2006, 39 (03) : 203 - 212
  • [27] Comparative investigation of two rotary nickel-titanium instruments:: ProTaper versus RaCe.: Part 2.: Cleaning effectiveness and shaping ability in severely curved root canals of extracted teeth
    Schäfer, E
    Vlassis, M
    INTERNATIONAL ENDODONTIC JOURNAL, 2004, 37 (04) : 239 - 248