The accuracy of the ATLAS muon X-ray tomograph

被引:5
|
作者
Avramidou, R [1 ]
Berbiers, J [1 ]
Boudineau, C [1 ]
Dechelette, C [1 ]
Drakoulakos, D [1 ]
Fabjan, C [1 ]
Grau, S [1 ]
Gschwendtner, E [1 ]
Maugain, JM [1 ]
Rieder, H [1 ]
Rangod, S [1 ]
Rohrbach, F [1 ]
Sbrissa, E [1 ]
Sedykh, E [1 ]
Sedykh, I [1 ]
Smirnov, Y [1 ]
Vertogradov, L [1 ]
Vichou, I [1 ]
机构
[1] CERN, CH-1211 Geneva 23, Switzerland
关键词
X-ray instrumentation; computerized tomography; LHC accelerators; ATLAS experiment; muon chamber detectors; quality control;
D O I
10.1016/S0168-9002(02)01611-X
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A gigantic detector, the ATLAS project, is under construction at CERN for particle physics research at the Large Hadron Collider which is to be ready by 2006. An X-ray tomograph has been developed, designed and constructed Lit CERN in order to control the mechanical quality of the ATLAS muon chambers. We reached a measurement accuracy of 2 mum systematic and 2 pin statistical uncertainties in the horizontal and vertical directions in the working area 220 cm (horizontal) x 60cm (vertical). Here we describe in detail the fundamental approach of the basic principle chosen to achieve such good accuracy. In order to crosscheck our precision, key results of measurements are presented. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:83 / 101
页数:19
相关论文
共 50 条
  • [31] The accuracy of X-ray masses of galaxy clusters
    Schindler, S
    ASTROPHYSICAL LETTERS & COMMUNICATIONS, 1997, 36 (1-6) : 173 - 179
  • [32] Image quality and accuracy in x-ray microtomography
    Davis, GR
    DEVELOPMENTS IN X-RAY TOMOGRAPHY II, 1999, 3772 : 147 - 155
  • [33] Accuracy evaluation of an X-ray microtomography system
    Fernandes, Jaquiel S.
    Appoloni, Carlos R.
    Fernandes, Celso P.
    MICRON, 2016, 85 : 34 - 38
  • [34] Retrospective Cardiac Gating with A Prototype Small- Animal X-ray Computed Tomograph
    Taschereau, Richard
    Chatziioannou, Arion F.
    Xu, Shili
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2025, (216):
  • [35] Polarized neutron imaging at NeXT (neutron and x-ray tomograph) at Institut Laue Langevin
    Oji, U. K.
    Tengattini, A.
    Helfen, L.
    Manke, I.
    Cubitt, R.
    Kardjilov, N.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2024, 95 (06):
  • [36] X-RAY DIFFERENTIAL DIAGNOSIS OF SECONDARY NASAL CAVITY DISEASES WITH SPECIAL CONSIDERATION OF TOMOGRAPH
    KLEY
    PRACTICA OTO-RHINO-LARYNGOLOGICA, 1968, 30 (02): : 124 - &
  • [37] EXPERIENCES WITH THE APPLICATION OF THE MEDICAL X-RAY COMPUTER TOMOGRAPH IN RESEARCH OF HISTORICAL AND ARTISTIC OBJECTS
    Peceny, Jakub
    ACTA ARTIS ACADEMICA 2010: THE STORY OF ART - ARTWORK CHANGES IN TIME, 2010, : 236 - 242
  • [38] Assessment of a new high-performance small-animal X-ray tomograph
    Vaquero, J. J.
    Redondo, S.
    Lage, E.
    Abella, M.
    Sisniega, A.
    Tapias, G.
    Montenegro, M. L. Soto
    Desco, M.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2008, 55 (03) : 898 - 905
  • [39] Resolution effects in a dense linear source array X-ray micro-tomograph
    Quan, Enzhuo
    Lalush, David S.
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2094 - 2097
  • [40] An All-Sky Atlas of Radio/X-ray Associations
    Flesch, E.
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF AUSTRALIA, 2010, 27 (03): : 283 - 289