Femtosecond pump-probe nondestructive examination of materials (invited)

被引:129
|
作者
Norris, PM [1 ]
Caffrey, AP
Stevens, RJ
Klopf, JM
McLeskey, JT
Smith, AN
机构
[1] Univ Virginia, Dept Mech & Aerosp Engn, Charlottesville, VA 22904 USA
[2] Univ Virginia, Dept Engn Phys, Charlottesville, VA 22904 USA
[3] Virginia Commonwealth Univ, Dept Mech Engn, Richmond, VA 23284 USA
[4] USN Acad, Dept Mech Engn, Annapolis, MD 21402 USA
来源
REVIEW OF SCIENTIFIC INSTRUMENTS | 2003年 / 74卷 / 01期
关键词
D O I
10.1063/1.1517187
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Ultrashort-pulsed lasers have been demonstrated as effective tools for the nondestructive examination (NDE) of energy transport properties in thin films. After the instantaneous heating of the surface of a 100 nm metal film, it will take similar to100 ps for the influence of the substrate to affect the surface temperature profile. Therefore, direct measurement of energy transport in a thin film sample requires a technique with picosecond temporal resolution. The pump-probe experimental technique is able to monitor the change in reflectance or transmittance of the sample surface as a function of time on a subpicosecond time scale. Changes in reflectance and transmittance can then be used to determine properties of the film. In the case of metals, the change in reflectance is related to changes in temperature and strain. The transient temperature profile at the surface is then used to determine the rate of coupling between the electron and phonon systems as well as the thermal conductivity of the material. In the case of semiconductors, the change in reflectance and transmittance is related to changes in the local electronic states and temperature. Transient thermotransmission experiments have been used extensively to observe electron-hole recombination phenomena and thermalization of hot electrons. Application of the transient thermoreflectance (TTR) and transient thermotransmittance (TTT) technique to the study of picosecond phenomena in metals and semiconductors will be discussed. The pump-probe experimental setup will be described, along with the details of the experimental apparatus in use at the University of Virginia. The thermal model applicable to ultrashort-pulsed laser heating of metals will be presented along with a discussion of the limitations of this model. Details of the data acquisition and interpretation of the experimental results will be given, including a discussion of the reflectance models used to relate the measured changes in reflectance to calculated changes in temperature. Finally, experimental results will be presented that demonstrate the use of the TTR technique for measuring the electron-phonon coupling factor and the thermal conductivity of thin metallic films. The use of the TTT technique to distinguish between different levels of doping and alloying in thin film samples of hydrogenated amorphous silicon will also be discussed briefly. (C) 2003 American Institute of Physics.
引用
收藏
页码:400 / 406
页数:7
相关论文
共 50 条
  • [31] Femtosecond real-time pump-probe imaging spectroscopy
    Furukawa, N
    Mair, CE
    Kleiman, VD
    Takeda, J
    APPLIED PHYSICS LETTERS, 2004, 85 (20) : 4645 - 4647
  • [32] Detailed investigation of the femtosecond pump-probe spectroscopy of the hydrated electron
    Yokoyama, K
    Silva, C
    Son, DH
    Walhout, PK
    Barbara, PF
    JOURNAL OF PHYSICAL CHEMISTRY A, 1998, 102 (35): : 6957 - 6966
  • [33] WAVEPACKET CALCULATIONS OF FEMTOSECOND PUMP-PROBE EXPERIMENTS ON THE SODIUM TRIMER
    DOBBYN, AJ
    HUTSON, JM
    JOURNAL OF PHYSICAL CHEMISTRY, 1994, 98 (44): : 11428 - 11438
  • [34] Femtosecond pump-probe reflectivity study of silicon carrier dynamics
    Sabbah, AJ
    Riffe, DM
    PHYSICAL REVIEW B, 2002, 66 (16) : 1 - 11
  • [35] A Perspective on Femtosecond Pump-Probe Spectroscopy in the Development of Future Sunscreens
    Whittock, Abigail L.
    Abiola, Temitope T.
    Stavros, Vasilios G.
    JOURNAL OF PHYSICAL CHEMISTRY A, 2022, 126 (15): : 2299 - 2308
  • [36] Theoretical modeling of femtosecond pump-probe spectroscopy in GaN systems
    Chang, YC
    Choi, CK
    Song, JJ
    ULTRAFAST PHENOMENA IN SEMICONDUCTORS V, 2001, 4280 : 58 - 69
  • [37] ULTRAFAST PUMP-PROBE SPECTROSCOPY - FEMTOSECOND DYNAMICS IN LIOUVILLE SPACE
    YAN, YJ
    FRIED, LE
    MUKAMEL, S
    JOURNAL OF PHYSICAL CHEMISTRY, 1989, 93 (25): : 8149 - 8162
  • [38] Femtosecond pump-probe near-field optical microscopy
    Nechay, BA
    Siegner, U
    Achermann, M
    Bielefeldt, H
    Keller, U
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1999, 70 (06): : 2758 - 2764
  • [39] Femtosecond pump-probe studies of nitrosyl chloride photochemistry in solution
    Cooksey, Catherine C.
    Johnson, Kevin J.
    Reid, Philip J.
    JOURNAL OF PHYSICAL CHEMISTRY A, 2006, 110 (28): : 8613 - 8622
  • [40] Determination of the temporal response function in femtosecond pump-probe systems