Prediction of charge collection efficiency in hadron-irradiated pad and pixel silicon detectors

被引:7
|
作者
Klingenberg, R. [1 ]
Krasel, O. [1 ]
Mass, M. [1 ]
Dobos, D. [1 ]
Goessling, C. [1 ]
Wunstorf, R. [1 ]
机构
[1] Univ Dortmund, D-44221 Dortmund, Germany
关键词
tracking and position-sensitive detectors; solid-state detectors; radiation effects; neutron and proton irradiation;
D O I
10.1016/j.nima.2006.05.273
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Transient Current Technique (TCT) is used to measure pulse shapes of charge collection and to derive trapping times in irradiated silicon pad detectors in a fluence range up to 10(15) n(eq) cm(-2). Simulations of electrical fields and charge collection mechanisms compared to the measurements of the TCT method allow to derive predictions of the charge collection efficiency. Independently, charge collection efficiencies have been determined in dedicated test beam data employing ATLAS pixel modules. Considering the geometry of pad and pixel structures the simulation for the tested fluence range can be verified and allows to extrapolate to larger fluences. This yields a useful input for the design of future silicon-based pixel detectors applicable in Super-LHC experiments. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 50 条
  • [21] Analysis and simulation of charge collection efficiency in silicon thin detectors
    Petasecca, M
    Moscatelli, F
    Pignatel, GU
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 546 (1-2): : 291 - 295
  • [22] Charge collection efficiency of standard and oxygenated silicon microstrip detectors
    Stavitski, I
    Rando, R
    Bisello, D
    Bacchetta, N
    Candelori, A
    Kaminski, A
    Wyss, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 485 (1-2): : 105 - 108
  • [23] Charge sharing in silicon pixel detectors
    Mathieson, K
    Passmore, MS
    Seller, P
    Prydderch, ML
    O'Shea, V
    Bates, RL
    Smith, KM
    Rahman, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 487 (1-2): : 113 - 122
  • [24] Simulation of signal in irradiated silicon pixel detectors
    Kramberger, G
    Contarato, D
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 511 (1-2): : 82 - 87
  • [25] MODELING AND SIMULATION OF CHARGE COLLECTION PROPERTIES FOR NEUTRON-IRRADIATED SILICON DETECTORS
    LI, Z
    KRANER, HW
    NUCLEAR PHYSICS B, 1993, : 398 - 409
  • [26] Evidence for plasma effect on charge collection efficiency in proton irradiated GaAs detectors
    Nava, F
    Vanni, P
    Canali, C
    Vittone, E
    Polesello, P
    Biggeri, U
    Leroy, C
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 426 (01): : 185 - 191
  • [27] Comprehensive study of the effects of irradiation on charge collection efficiency in silicon detectors
    Borrello, L
    Dell'Orso, R
    Dutta, S
    Gennai, S
    Mariani, M
    Messineo, A
    Segneri, G
    Starodumov, A
    Teodorescu, L
    Tonelli, G
    Verdini, PG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 461 (1-3): : 178 - 181
  • [28] Charge collection efficiency in double-sided silicon microstrip detectors
    Hoffman, KD
    Bortoletto, D
    Cihangir, S
    Spalding, J
    GarciaSciveres, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1996, 379 (02): : 237 - 242
  • [29] Charge collection efficiency of irradiated silicon detector operated at cryogenic temperatures
    Borer, K
    Janos, S
    Palmieri, VG
    Dezillie, B
    Li, Z
    Collins, P
    Niinikoski, TO
    Lourenço, C
    Sonderegger, P
    Borchi, E
    Bruzzi, M
    Pirollo, S
    Granata, V
    Pagano, S
    Chapuy, S
    Dimcovski, Z
    Grigoriev, E
    Bell, W
    Devine, SRH
    O'Shea, V
    Smith, K
    Berglund, P
    de Boer, W
    Hauler, F
    Heising, S
    Jungermann, L
    Casagrande, L
    Cindro, V
    Mikuz, M
    Zavartanik, M
    da Viá, C
    Esposito, A
    Konorov, I
    Paul, S
    Schmitt, L
    Buontempo, S
    D'Ambrosio, N
    Pagano, S
    Ruggiero, G
    Eremin, V
    Verbitskaya, E
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2000, 440 (01): : 5 - 16
  • [30] CHARGE COLLECTION IN SILICON STRIP DETECTORS
    BELAU, E
    KLANNER, R
    LUTZ, G
    NEUGEBAUER, E
    SEEBRUNNER, HJ
    WYLIE, A
    BOHRINGER, T
    HUBBELING, L
    WEILHAMMER, P
    KEMMER, J
    KOTZ, U
    RIEBESELL, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1983, 214 (2-3): : 253 - 260