Prediction of charge collection efficiency in hadron-irradiated pad and pixel silicon detectors

被引:7
|
作者
Klingenberg, R. [1 ]
Krasel, O. [1 ]
Mass, M. [1 ]
Dobos, D. [1 ]
Goessling, C. [1 ]
Wunstorf, R. [1 ]
机构
[1] Univ Dortmund, D-44221 Dortmund, Germany
关键词
tracking and position-sensitive detectors; solid-state detectors; radiation effects; neutron and proton irradiation;
D O I
10.1016/j.nima.2006.05.273
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The Transient Current Technique (TCT) is used to measure pulse shapes of charge collection and to derive trapping times in irradiated silicon pad detectors in a fluence range up to 10(15) n(eq) cm(-2). Simulations of electrical fields and charge collection mechanisms compared to the measurements of the TCT method allow to derive predictions of the charge collection efficiency. Independently, charge collection efficiencies have been determined in dedicated test beam data employing ATLAS pixel modules. Considering the geometry of pad and pixel structures the simulation for the tested fluence range can be verified and allows to extrapolate to larger fluences. This yields a useful input for the design of future silicon-based pixel detectors applicable in Super-LHC experiments. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:34 / 40
页数:7
相关论文
共 50 条
  • [1] Charge collection efficiency studies with irradiated silicon detectors
    Allport, PP
    Bowcock, TJV
    Casse, G
    Greenall, A
    Jackson, JN
    García, SMI
    Turner, PR
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 501 (01): : 146 - 152
  • [2] Determination of the Charge Collection Efficiency in Neutron Irradiated Silicon Detectors
    Petterson, M. K.
    Hurley, R. F.
    Arya, K.
    Betancourt, C.
    Bruzzi, M.
    Colby, B.
    Gerling, M.
    Meyer, C.
    Pixley, J.
    Rice, T.
    Sadrozinski, H. F. -W.
    Scaringella, M.
    Bernardini, J.
    Borrello, L.
    Fiori, F.
    Messineo, A.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2009, 56 (06) : 3828 - 3833
  • [3] Determination of the charge collection efficiency in neutron irradiated silicon detectors
    Petterson, M. K.
    Hurley, R. F.
    Arya, K.
    Betancourt, C.
    Bruzzi, M.
    Colby, B.
    Gerling, M.
    Meyer, C.
    Pixley, J.
    Rice, T.
    Sadrozinski, H. F. -W.
    Bernardini, J.
    Borrello, L.
    Fiori, F.
    Messineo, A.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 1329 - +
  • [4] Charge collection efficiency simulations of irradiated silicon strip detectors
    Peltola, T.
    JOURNAL OF INSTRUMENTATION, 2014, 9
  • [5] Temperature dependence of the charge collection efficiency in heavily irradiated silicon detectors
    Bell, WH
    Casagrande, L
    Da Via, C
    Granata, V
    Palmieri, VG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 435 (1-2): : 187 - 193
  • [6] Simulating charge collection in silicon pixel detectors
    Pindo, M
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1997, 395 (03): : 360 - 368
  • [7] Temperature dependence of the charge collection efficiency in heavily irradiated silicon detectors
    Bell, William H.
    Casagrande, Luca
    Da Via, Cinzia
    Granata, Valeria
    Palmieri, Vittorio G.
    Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 1999, 435 (1-2): : 187 - 193
  • [8] Study of anomalous charge collection efficiency in heavily irradiated silicon strip detectors
    Mikuz, M.
    Cindro, V.
    Kramberger, G.
    Mandic, I.
    Zavrtanik, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 636 : S50 - S55
  • [9] Charge collection and electrical characterization of neutron irradiated silicon pad detectors for the CMS High Granularity Calorimeter
    Akchurin, N.
    Almeida, P.
    Altopp, G.
    Alyari, M.
    Bergauer, T.
    Brondolin, E.
    Burkle, B.
    Frey, W. D.
    Gecse, Z.
    Heintz, U.
    Hinton, N.
    Kuryatkov, V
    Lipton, R.
    Mannelli, M.
    Mengke, T.
    Paulitsch, P.
    Peltola, T.
    Pitters, F.
    Sicking, E.
    Spencer, E.
    Tripathi, M.
    Pinto, M. V. Barreto
    Voelker, J.
    Wang, Z.
    Yohay, R.
    JOURNAL OF INSTRUMENTATION, 2020, 15 (09):
  • [10] Charge collection and noise analysis of heavily irradiated silicon detectors
    Borchi, E
    Bruzzi, M
    Leroy, C
    Pirollo, S
    Sciortino, S
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (02) : 141 - 145