There are various scanners available in dental practice with various accuracies. The aim of this study was to compare the 3D capturing accuracy of scans obtained from Trios 3 and Dental Wings scanner. A reference mandibular model was printed from FormLab with reference points in three axes (X, Y, and XY and Z). The printed model was scanned 5 times with 3 scans: normal scan by Trios 3 (Trios 3A), high-resolution scan by Trios 3 (Trios 3B), and normal scan by Dental Wings. After scan, the stereolithography (stl) files were generated. Then, the measurements were made from the computer software using Rhinoceros 3D (Rhino, Robert Mc Neel & Associates for Windows, Washington DC, USA). The measurements made with digital caliper were taken as control. Statistical analysis was done using one-way ANOVA with post hoc using Sheffe (P < 0.01). Trios 3 presented higher accuracy than Dental Wings and high resolution showed better results. The Dental Wings showed less accuracy at the measurements >50 mm of length and >30mmin width. There was no significant difference (P > 0.05) of control with the Trios 3A and Trios 3B. Similarly, for the measurements in Z-axis, there was no significant difference of control with each scan (Trios 3A, Trios 3B, and Dental Wings). Accuracy of the scan is affected by the length of the scanning area and scanning pattern. It is less recommended to Dental Wings scan >3-unit prosthesis and that crosses the midline.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Assessment of Compatibility between Various Intraoral Scanners and 3D Printers through an Accuracy Analysis of 3D Printed Models
    Im, Chang-Hee
    Park, Ji-Man
    Kim, Jang-Hyun
    Kang, You-Jung
    Kim, Jee-Hwan
    MATERIALS, 2020, 13 (19) : 1 - 16
  • [32] INFLUENCE OF THE MATERIAL ON THE ACCURACY OF OPTICAL 3D DIGITALISATION
    Mendricky, Radomir
    Langer, Ondrej
    MM SCIENCE JOURNAL, 2019, 2019 : 2783 - 2789
  • [33] ASPECTS AFFECTING ACCURACY OF OPTICAL 3D DIGITIZATION
    Mendricky, Radomir
    MM SCIENCE JOURNAL, 2018, 2018 : 2267 - 2275
  • [34] 3D Monitoring and Quality Control Using Intraoral Optical Camera Systems
    Mehl, A.
    Koch, R.
    Zaruba, M.
    Ender, A.
    INTERNATIONAL JOURNAL OF COMPUTERIZED DENTISTRY, 2013, 16 (01) : 23 - 36
  • [35] Accuracy of single implant scans with a combined healing abutment-scan body system and different intraoral scanners: An in vitro study
    Cakmak, Gulce
    Donmez, Mustafa Borga
    Atalay, Sevda
    Yilmaz, Hakan
    Kokat, Ali Murat
    Yilmaz, Burak
    JOURNAL OF DENTISTRY, 2021, 113
  • [36] Effect of pulp chamber depth on the accuracy of endocrown scans made with different intraoral scanners versus an industrial scanner: An in vitro study
    Gurpinar, Bahar
    Tak, Onjen
    JOURNAL OF PROSTHETIC DENTISTRY, 2022, 127 (03): : 430 - 437
  • [37] Digital workflow: In vitro accuracy of 3D printed casts generated from complete-arch digital implant scans
    Papaspyridakos, Panos
    Chen, Yo-Wei
    Alshawaf, Bahaa
    Kang, Kiho
    Finkelman, Matthew
    Chronopoulos, Vasilios
    Weber, Hans-Peter
    JOURNAL OF PROSTHETIC DENTISTRY, 2020, 124 (05): : 589 - 593
  • [38] 3D-accuracy of conventional and intraoral-optical (CEREC®) impression procedures.
    Luthardt, RG
    Bornemann, G
    Lemelson, S
    Claas, H
    JOURNAL OF DENTAL RESEARCH, 2002, 81 : A402 - A402
  • [39] Effect of auxiliary geometric devices on the accuracy of intraoral scans in full-arch implant-supported rehabilitations: An in vitro study
    Canullo, Luigi
    Pesce, Paolo
    Caponio, Vito Carlo Alberto
    Iacono, Roberta
    Raffone, Carlo
    Luciani, Francesco Saverio
    Menini, Maria
    JOURNAL OF DENTISTRY, 2024, 145
  • [40] Accuracy of intraoral scanners in maxillary multiple restorations: An in vitro study
    Aung, Hlaing Myint Myat
    Linn, Thu Ya
    Lee, Wei-Fang
    Chao, Jen-Chih
    Teng, Nai-Chia
    Renn, Ting-Yi
    Chang, Wei-Jen
    JOURNAL OF DENTAL SCIENCES, 2024, 19 : S116 - S121