High precision cadmium isotope analysis of geological reference materials by double spike MC-ICP-MS

被引:1
|
作者
Peng, Huan [1 ]
He, Dong [1 ]
Guo, Rui [1 ]
Liu, Xing [1 ]
Belshaw, Nicholas S. [2 ]
Zheng, Hongtao [3 ]
Hu, Shenghong [1 ,4 ]
Zhu, Zhenli [1 ]
机构
[1] China Univ Geosci, State Key Lab Biogeol & Environm Geol, Wuhan 430074, Peoples R China
[2] Univ Oxford, Dept Earth Sci, Oxford OX1 3AN, England
[3] China Univ Geosci, Fac Mat Sci & Chem, Wuhan 430074, Peoples R China
[4] China Univ Geosci, Fac Earth Sci, Wuhan 430074, Peoples R China
基金
美国国家科学基金会;
关键词
PRIMARY PRODUCTIVITY; MASS FRACTIONATION; TRACE CADMIUM; CD ISOTOPES; POLLUTION; SAMPLES; SOILS;
D O I
10.1039/d0ja00424c
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this study, we develop a method for high precision Cd isotope analysis by double spike MC-ICP-MS. Two-step Cd purification using AG-MP-1M resin and TRU resin was used to separate Cd from samples with a recovery of more than 95% Cd and a blank less than 0.1 ng. A practical double spike design and optimization procedure is proposed and the effect of the double spike ratio in the double spike-sample mixture (p) on the measured delta Cd-114/110 is evaluated, which broadens the appropriate p range from 0.3-0.6 to 0.1-0.8. In addition, the observed shift/deviation of the measured delta Cd-114/110(NIST 3108) value from zero-delta due to the change of experimental conditions is discussed on a theoretical basis and a correction approach is developed. Potential Mo and Zr based polyatomic ions have no significant effect on delta Cd-114/110 in typical geological samples, while isobaric ions such as Sn, Pd and In can seriously affect the accuracy of measurements even at low concentration. It is shown that the tolerances of isobaric interference can be improved to 0.1, 0.05 and 0.02 for Sn/Cd, Pd/Cd and In/Cd, respectively, after mass discrimination correction. The precision and accuracy of the proposed method were verified by analyzing mixtures of NIST 3108 and a secondary reference material BGEG-Cd of different composition. Long term monitoring of the measured NIST 3108 and BGEG-Cd showed repeatability for delta Cd-114/110 of 0.00 +/- 0.04 parts per thousand and -1.00 +/- 0.04 parts per thousand (2sd, n = 45), respectively. Finally, we measured Cd isotope compositions of several geological standard materials including soil sediments and manganese nodules, and the delta Cd-114/110 values of 0.01 +/- 0.02 parts per thousand (GSD-5a), 0.04 +/- 0.02 parts per thousand (GSD-7a), -0.06 +/- 0.05 parts per thousand (GSD-10), -0.34 +/- 0.06 parts per thousand (GSD-11), -0.10 +/- 0.06 parts per thousand (GSD-12), 0.10 +/- 0.04 parts per thousand (GSD-17), 0.05 +/- 0.03 parts per thousand (GSD-21), and 0.10 +/- 0.07 parts per thousand (GSD-23) were in good agreement with the reported values, and a delta Cd-114/110 value of -0.08 +/- 0.04 parts per thousand (GSD-3a) was reported for the first time.
引用
收藏
页码:390 / 398
页数:9
相关论文
共 50 条
  • [41] Accurate and high-precision measurement of lithium isotopes in two reference materials by MC-ICP-MS
    Millot, R
    Guerrot, C
    Vigier, N
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2004, 28 (01) : 153 - 159
  • [42] High-Precision Mass-Dependent Molybdenum Isotope Variations in Magmatic Rocks Determined by Double-Spike MC-ICP-MS
    Willbold, Matthias
    Hibbert, Kate
    Lai, Yi-Jen
    Freymuth, Heye
    Hin, Remco C.
    Coath, Christopher
    Vils, Flurin
    Elliott, Tim
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2016, 40 (03) : 389 - 403
  • [43] An Analytical Method for Quantification of Sn Isotope Variations in Geological Materials Using MC-ICP-MS
    Pathak, Dipankar
    Mezger, Klaus
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2024, : 863 - 885
  • [44] Magnesium isotope analysis using a MC-ICP-MS
    Choi, Min Seok
    Lee, Sin-Woo
    Ryu, Jong-Sik
    Lee, Kwang-Sik
    Shin, Hyung Seon
    JOURNAL OF THE GEOLOGICAL SOCIETY OF KOREA, 2012, 48 (04) : 357 - 363
  • [45] High precision determination of silver isotope ratios in commercial products by MC-ICP-MS
    Yang, Lu
    Dabek-Zlotorzynska, Ewa
    Celo, Valbona
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2009, 24 (11) : 1564 - 1569
  • [46] Cadmium isotope ratio measurements in environmental matrices by MC-ICP-MS
    Pallavicini, Nicola
    Engstrom, Emma
    Baxter, Douglas C.
    Ohlander, Bjorn
    Ingri, Johan
    Rodushkin, Ilia
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (09) : 1570 - 1584
  • [47] High-precision copper and iron isotope analysis of igneous rock standards by MC-ICP-MS
    Liu, Sheng-Ao
    Li, Dandan
    Li, Shuguang
    Teng, Fang-Zhen
    Ke, Shan
    He, Yongsheng
    Lu, Yinghuai
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (01) : 122 - 133
  • [48] Ultra-precise titanium stable isotope measurements by double-spike high resolution MC-ICP-MS
    Millet, Marc-Alban
    Dauphas, Nicolas
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2014, 29 (08) : 1444 - 1458
  • [49] Accurate and precise determination of stable Cr isotope compositions in carbonates by double spike MC-ICP-MS
    Bonnand, Pierre
    Parkinson, Ian J.
    James, Rachael H.
    Karjalainen, Anne-Mari
    Fehr, Manuela A.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (03) : 528 - 535
  • [50] The stable Cr isotope inventory of solid Earth reservoirs determined by double spike MC-ICP-MS
    Schoenberg, R.
    Zink, S.
    Staubwasser, M.
    von Blanckenburg, F.
    CHEMICAL GEOLOGY, 2008, 249 (3-4) : 294 - 306