Detection of chemical warfare agent simulants and hydrolysis products in biological samples by paper spray mass spectrometry

被引:61
|
作者
McKenna, Josiah [1 ]
Dhummakupt, Elizabeth S. [2 ]
Connell, Theresa [3 ]
Demond, Paul S. [3 ]
Miller, Dennis B. [2 ]
Nilles, J. Michael [3 ]
Manicke, Nicholas E. [1 ]
Glaros, Trevor [2 ]
机构
[1] Indiana Univ Purdue Univ Indianapolis, Dept Chem & Chem Biol, Indianapolis, IN 46202 USA
[2] US Army, BioSci Div, BioDef Branch, Edgewood Chem Biol Ctr, Aberdeen Proving Ground, MD 21010 USA
[3] Excet Inc, 6225 Brandon Ave,Suite 360, Springfield, VA 22150 USA
关键词
ELECTROSPRAY-IONIZATION; QUANTITATIVE-ANALYSIS; ELECTRIC-DISCHARGE; MS; DERIVATIZATION; SUPPRESSION; DRUGS;
D O I
10.1039/c7an00144d
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Paper spray ionization coupled to a high resolution tandem mass spectrometer (a quadrupole orbitrap) was used to identify and quantitate chemical warfare agent (CWA) simulants and their hydrolysis products in blood and urine. Three CWA simulants, dimethyl methylphosphonate (DMMP), trimethyl phosphate (TMP), and diisopropyl methylphosphonate (DIMP), and their isotopically labeled standards were analyzed in human whole blood and urine. Calibration curves were generated and tested with continuing calibration verification standards. Limits of detection for these three compounds were in the low ng mL(-1) range for the direct analysis of both blood and urine samples. Five CWA hydrolysis products, ethyl methylphosphonic acid (EMPA), isopropyl methylphosphonic acid (IMPA), isobutyl methylphosphonic acid (iBuMPA), cyclohexyl methylphosphonic acid (CHMPA), and pinacolyl methylphosphonic acid (PinMPA), were also analyzed. Calibration curves were generated in both positive and negative ion modes. Limits of detection in the negative ion mode ranged from 0.36 ng mL(-1) to 1.25 ng mL(-1) in both blood and urine for the hydrolysis products. These levels were well below those found in victims of the Tokyo subway attack of 2 to 135 ng mL(-1.1) Improved stability and robustness of the paper spray technique in the negative ion mode was achieved by the addition of chlorinated solvents. These applications demonstrate that paper spray mass spectrometry (PS-MS) can be used for rapid, sample preparation-free detection of chemical warfare agents and their hydrolysis products at physiologically relevant concentrations in biological samples.
引用
收藏
页码:1442 / 1451
页数:10
相关论文
共 50 条
  • [41] In situ NMR analysis of chemical warfare agent simulants and their reaction products with nanomaterials in a perfluoropolymer matrix.
    Hobson, ST
    Sartori, DA
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2001, 221 : U617 - U617
  • [42] Construction of MOF-loaded polypropylene nonwoven fabrics for fast catalytic hydrolysis of chemical warfare agent simulants
    Zhang, Shiyu
    Dong, Chenshan
    Wang, Yilun
    Huang, Jingjing
    Gu, Shaojin
    Yang, Hongjun
    Liu, Xin
    Xu, Weilin
    Ye, Dezhan
    MATERIALS LETTERS, 2022, 326
  • [43] Detecting drugs and chemical agents in biological samples by paper spray mass dpectrometry: Applications and new developments
    Manicke, Nicholas
    Zhang, Chengsen
    Bills, Brandon
    Potter, Rachel
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2015, 250
  • [44] Detection and Quantification of Chemical Warfare Agent Precursors and Surrogates by Selected Ion Flow Tube Mass Spectrometry
    Francis, Gregory J.
    Milligan, Daniel B.
    McEwan, Murray J.
    ANALYTICAL CHEMISTRY, 2009, 81 (21) : 8892 - 8899
  • [45] Analysis of Biological Samples Using Paper Spray Mass Spectrometry: An Investigation of Impacts by the Substrates, Solvents and Elution Methods
    Ren, Yue
    Wang, He
    Liu, Jiangjiang
    Zhang, Zhiping
    McLuckey, Morgan N.
    Ouyang, Zheng
    CHROMATOGRAPHIA, 2013, 76 (19-20) : 1339 - 1346
  • [46] Rapid screening of aqueous chemical warfare agent degradation products: Ambient pressure ion mobility mass spectrometry
    Steiner, WE
    Clowers, BH
    Matz, LM
    Siems, WF
    Hill, HH
    ANALYTICAL CHEMISTRY, 2002, 74 (17) : 4343 - 4352
  • [47] Analysis of Biological Samples Using Paper Spray Mass Spectrometry: An Investigation of Impacts by the Substrates, Solvents and Elution Methods
    Yue Ren
    He Wang
    Jiangjiang Liu
    Zhiping Zhang
    Morgan N. McLuckey
    Zheng Ouyang
    Chromatographia, 2013, 76 : 1339 - 1346
  • [48] Surface-enhanced Raman scattering, detection of chemical and biological agent simulants
    Yan, F
    Wabuyele, MB
    Griffin, GD
    Vass, AA
    Vo-Dinh, T
    IEEE SENSORS JOURNAL, 2005, 5 (04) : 665 - 670
  • [49] Graphene Nanoplatelet-Polymer Chemiresistive Sensor Arrays for the Detection and Discrimination of Chemical Warfare Agent Simulants
    Wiederoder, Michael S.
    Nallon, Eric C.
    Weiss, Matt
    McGraw, Shannon K.
    Schnee, Vincent P.
    Bright, Collin J.
    Polcha, Michael P.
    Paffenroth, Randy
    Uzarski, Joshua R.
    ACS SENSORS, 2017, 2 (11): : 1669 - 1678
  • [50] Paper-capillary spray for direct mass spectrometry analysis of biofluid samples
    Yue Ren
    Spencer Chiang
    Wenpeng Zhang
    Xiao Wang
    Ziqing Lin
    Zheng Ouyang
    Analytical and Bioanalytical Chemistry, 2016, 408 : 1385 - 1390