A Monte Carlo investigation of fluence profiles collimated by an electron specific MLC during beam delivery for modulated electron radiation therapy

被引:15
|
作者
Deng, J
Lee, MC
Ma, CM
机构
[1] Yale Univ, Sch Med, Dept Therapeut Radiol, New Haven, CT 06510 USA
[2] Stanford Univ, Sch Med, Dept Radiat Oncol, Stanford, CA 94305 USA
[3] Fox Chase Canc Ctr, Dept Radiat Oncol, Philadelphia, PA 19111 USA
关键词
electron beams; multileaf collimator; beam collimation; EGS4 Monte Carlo;
D O I
10.1118/1.1513160
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Modulated electron radiation therapy (MERT) is able to deliver conformal dose to shallow tumors while significantly reducing dose to distal structures and surrounding tissues. An electron specific multileaf collimator (eMLC) has been proposed and constructed as an effective means of delivering electron beams for MERT. The aim of this work is to apply the Monte Carlo method to investigate the fluence profiles collimated by the eMLC in order to achieve accurate beam delivery for MERT. In this work, the EGS4/BEAM code was used to simulate the eMLC collimated electron beams of 6-20 MeV generated from a Varian Clinac 2100C linear accelerator. An attempt was made to describe the fluence profiles with an analytic Sigmoid function. The function parameters were determined by the fittings of the Monte Carlo simulated fluence profiles. How the function parameters depend on the eMLC aperture size, the off-axis location, and the electron beam energy has been investigated. It has been found that the eMLC collimated fluence profiles are dependent on beam energy, while almost independent of leaf location or dimension of MLC aperture. There is little difference in the fluence profiles collimated by the leaf side and the leaf end for the straight-edged leaves. It is possible that these energy-dependent Sigmoid functions can serve as operators to account for the energy dependence of the eMLC collimated fluence profiles. These operators can be incorporated into the inverse planning algorithm to derive desired dose distributions using a set of electron beams of variable energy and field size suitable for delivery by the eMLC. (C) 2002 American Association of Physicists in Medicine.
引用
收藏
页码:2472 / 2483
页数:12
相关论文
共 50 条
  • [31] Optimization of conformal electron beam therapy using energy- and fluence-modulated beams
    Hyodynmaa, S
    Gustafsson, A
    Brahme, A
    MEDICAL PHYSICS, 1996, 23 (05) : 659 - 666
  • [32] Automated delivery and quality assurance of modulated electron radiation therapy for breast
    Connell, T.
    Papaconstadopoulos, P.
    Alexander, A.
    Serban, M.
    Devic, S.
    Seuntjens, J.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S284 - S284
  • [33] Automated delivery and quality assurance of a modulated electron radiation therapy plan
    Connell, T.
    Alexander, A.
    Papaconstadopoulos, P.
    Serban, M.
    Devic, S.
    Seuntjens, J.
    MEDICAL PHYSICS, 2014, 41 (08) : 5 - 6
  • [34] Total skin electron therapy treatment: Monte Carlo verification and beam characteristics
    Carrasco, E
    Sanchez-Doblado, F
    Leal, A
    Capote, R
    Lagares, J
    Rosello, J
    Perucha, M
    Arrans, R
    RADIOTHERAPY AND ONCOLOGY, 2003, 68 : S92 - S92
  • [35] Monte Carlo study of modulated electron delivery using a conventional multi-leaf collimator
    Xiong, W
    Li, J
    Price, R
    McNeeley, S
    Qin, L
    Ma, C
    MEDICAL PHYSICS, 2004, 31 (06) : 1904 - 1904
  • [36] Monte Carlo investigation of electron specific energy distribution in a single cell model
    V. M. Markovic
    N. Stevanovic
    D. Nikezic
    Radiation and Environmental Biophysics, 2020, 59 : 161 - 171
  • [37] Monte Carlo investigation of electron specific energy distribution in a single cell model
    Markovic, V. M.
    Stevanovic, N.
    Nikezic, D.
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2020, 59 (01) : 161 - 171
  • [38] Development and verification of an electron Monte Carlo engine for applications in intraoperative radiation therapy
    Rank, Luisa
    Lysakovski, Peter
    Major, Gerald
    Ferrari, Alfredo
    Tessonnier, Thomas
    Debus, Juergen
    Mairani, Andrea
    MEDICAL PHYSICS, 2024, 51 (09) : 6348 - 6364
  • [39] A Monte Carlo study of the variation of electron fluence in water from a 6 MV photon beam outside of the field
    Kirkby, C.
    Field, C.
    MacKenzie, M.
    Syme, A.
    Fallone, B. G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (12): : 3563 - 3578
  • [40] Monte Carlo Analyses of the NEO Beam Electron Beam Facility for Space Solar Cell Radiation Qualification
    Messenger, Scott R.
    Warner, Jeffrey H.
    Uribe, Roberto
    Walters, Robert J.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2010, 57 (06) : 3470 - 3476