Development of an Assemblable, Daily, Quality-Assurance Device for Line-Scanning Proton Therapy

被引:1
|
作者
Chung, Kwangzoo [1 ]
Park, Jihyun [1 ]
Ahn, Sung Hwan [1 ]
Han, Youngyih [1 ]
Lim, Do Hoon [1 ]
机构
[1] Sungkyunkwan Univ, Sch Med, Dept Radiat Oncol, Samsung Med Ctr, Seoul 06351, South Korea
基金
新加坡国家研究基金会;
关键词
Proton beam therapy; Daily QA; Pencil beam scanning; Line-scanning; PLANNING SYSTEM; TECHNICAL NOTE; LOG FILES; DAILY QA; ION; BEAMS;
D O I
10.3938/jkps.75.344
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
Proton beam therapy requires a reliable and efficient method of daily quality assurance. Various daily quality-assurance systems were developed for a simple and efficient quality assurance of spot-scanning proton therapy nozzles. To promote the same effectiveness in daily quality assurance of line-scanning proton therapy nozzles, we developed an assemblable, all-in-one, daily, quality-assurance system for line-scanning proton therapy nozzles. The system uses a high-density polyethylene device mounted on a two-dimensional ionization chamber array detector. The device is modularized for routine daily quality-assurance activities (output measurements, range verifications, and scan pattern measurements). A proton beam delivery plan was created for daily quality assurance based on the CT-scanned image of the device. Each step of the daily quality-assurance procedure was tested with the developed system. Using the developed system, proton beam range verifications and gamma analysis of the scan pattern test were combined into a measurement with a single beam delivery. The developed system will improve the efficiency of daily quality assurance for line-scanning nozzles while using an assemblable design to add flexibility.
引用
收藏
页码:344 / 349
页数:6
相关论文
共 50 条
  • [1] Development of an Assemblable, Daily, Quality-Assurance Device for Line-Scanning Proton Therapy
    Kwangzoo Chung
    Jihyun Park
    Sung Hwan Ahn
    Youngyih Han
    Do Hoon Lim
    Journal of the Korean Physical Society, 2019, 75 : 344 - 349
  • [2] Evaluation of a prototype array for daily quality assurance in spot scanning proton therapy
    Flatten, Veronika
    Devendranath, Henry-Aravinth
    Kroh, Janik
    Witt, Matthias
    Baumann, Kilian-Simon
    Gall, Kenneth
    Simon, Bill
    Wulff, Joerg
    Schoenfeld, Andreas A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2024, 25 (11):
  • [3] A fast and reliable method for daily quality assurance in spot scanning proton therapy with a compact and inexpensive phantom
    Bizzocchi, Nicola
    Fracchiolla, Francesco
    Schwarz, Marco
    Algranati, Carlo
    MEDICAL DOSIMETRY, 2017, 42 (03) : 238 - 246
  • [4] A comprehensive and efficient daily quality assurance for PBS proton therapy
    Actis, O.
    Meer, D.
    Koenig, S.
    Weber, D. C.
    Mayor, A.
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (05): : 1661 - 1675
  • [5] DEVELOPMENT OF A QUALITY-ASSURANCE SYSTEM FOR A WINE PRODUCER IN GREECE
    TAGARAS, G
    GEORGIADIS, P
    PSOINOS, D
    INTERFACES, 1994, 24 (06) : 1 - 13
  • [6] Medipix detectors in radiation therapy for advanced quality-assurance
    Rosenfeld, Anatoly
    Alnaghy, Saree
    Petasecca, Marco
    Cutajar, Dean
    Lerch, Michael
    Pospisil, Stanislav
    Giacometti, Valentina
    Schulte, Reinhard
    Rosso, Valeria
    Wuerl, Matthias
    Granja, Carlos
    Martisikova, Maria
    Parodi, Katia
    RADIATION MEASUREMENTS, 2020, 130
  • [7] Development of a Quality Assurance Phantom for Proton Radiographic Images Using the MEVION Spot Scanning Proton Therapy System
    Pelas, C.
    Richards, Z.
    Alsbou, N.
    Ahmad, S.
    Ali, I.
    MEDICAL PHYSICS, 2020, 47 (06) : E527 - E527
  • [8] Characterization of a novel detector array for daily quality assurance in proton therapy
    Devendranath, H.
    Flatten, V.
    Chofor, N.
    Wulff, J.
    Timmermann, B.
    Schoenfeld, A. A.
    RADIOTHERAPY AND ONCOLOGY, 2023, 182 : S1410 - S1411
  • [9] Comprehensive Quality Assurance Procedures for Uniform Scanning Proton Therapy Machines
    Zheng, Y.
    Ding, X.
    Mascia, A.
    Hsi, W.
    Kang, Y.
    Ramirez, E.
    Zeidan, O.
    Schreuder, N.
    MEDICAL PHYSICS, 2012, 39 (06) : 3749 - 3749
  • [10] Detectors for quality assurance of pencil beam scanning gantries for proton therapy
    Gagnon-Moisan, F.
    van der Meer, R.
    Chowdhuri, Z.
    Eichin, M.
    Koenig, S.
    Schmid, F. -J.
    Weber, D. C.
    RADIOTHERAPY AND ONCOLOGY, 2016, 118 : S44 - S45