Medipix detectors in radiation therapy for advanced quality-assurance

被引:12
|
作者
Rosenfeld, Anatoly [1 ]
Alnaghy, Saree [1 ]
Petasecca, Marco [1 ]
Cutajar, Dean [1 ]
Lerch, Michael [1 ]
Pospisil, Stanislav [2 ]
Giacometti, Valentina [3 ]
Schulte, Reinhard [4 ]
Rosso, Valeria [5 ,6 ]
Wuerl, Matthias [7 ]
Granja, Carlos [8 ]
Martisikova, Maria [9 ,10 ,11 ]
Parodi, Katia [7 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW, Australia
[2] Czech Tech Univ, Inst Expt & Appl Phys, Prague, Czech Republic
[3] Queens Univ Belfast, Sch Med Dent & Biomed Sci, Belfast, Antrim, North Ireland
[4] Loma Linda Univ, Sch Med, Loma Linda, CA USA
[5] Univ Pisa, Dept Phys, Pisa, Italy
[6] Ist Nazl Fis Nucl, Sez Pisa, Pisa, Italy
[7] Ludwig Maximilians Univ Munchen, Dept Med Phys, Munich, Germany
[8] Advacam, Prague, Czech Republic
[9] German Canc Res Ctr, Heidelberg, Germany
[10] Heidelberg Inst Radiat Oncol, Heidelberg, Germany
[11] Natl Ctr Radiat Res Oncol, Heidelberg, Germany
关键词
Medipix; Quality assurance; Semiconductor detectors; Radiotherapy; Particle therapy; CARBON ION-BEAMS; CHARGED-PARTICLE; OCULAR MELANOMA; PROTON-BEAM; IN-BEAM; TIMEPIX; SYSTEM; VISUALIZATION; DOSIMETRY; PATH;
D O I
10.1016/j.radmeas.2019.106211
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Spectroscopy-based photon-counting detector systems, Medipix, have many applications in medicine. Medipix detectors benefit from providing energy information as well as high spatial resolution. In this article, a review of Medipix detector technology applied to medicine and imaging techniques are presented. The technology has been used to develop quality assurance (QA) measurement devices in radiation-based treatments. A gamma camera system for radiotherapy has been developed to measure dose delivered to prostate treatments in realtime. The advantage of a high-resolution detector has been utilized in proton and heavy ion therapy for dose QA, measuring the charge particle spectra, and beam geometry for mini-beams. Applications in medical imaging using helium ion beams have been investigated to replace CT for ion beam radiotherapy. This technique provides many advantages over conventional CT such as high-resolution imaging and spectroscopy-based information for planning in helium ion treatments. The Medipix technology has shown it can be broadly applied in radiation and particle therapy applications for accurate QA as well as proving high-resolution imaging in medicine.
引用
收藏
页数:18
相关论文
共 50 条
  • [1] QUALITY-ASSURANCE IN NEUROLOGY
    WUSCHITZ, A
    NEUROPSYCHIATRIE, 1995, 9 (01): : 32 - 33
  • [2] QUALITY-ASSURANCE TECHNOLOGY IN JAPAN
    KISHIDA, K
    TERAMOTO, M
    TORII, K
    URANO, Y
    IEEE SOFTWARE, 1987, 4 (05) : 11 - 18
  • [3] QUALITY-ASSURANCE STANDARDS AND PRACTICES
    LANGSTON, ME
    NUCLEAR SAFETY, 1971, 12 (06): : 549 - &
  • [4] GOALS AND MEASURES IN QUALITY-ASSURANCE
    MANGER, H
    F&M-FEINWERKTECHNIK & MESSTECHNIK, 1988, 96 (04): : ZM5 - ZM6
  • [5] PSRO, QUALITY-ASSURANCE BLUES
    KOMAROFF, AL
    NEW ENGLAND JOURNAL OF MEDICINE, 1978, 298 (21): : 1194 - 1196
  • [6] Optically stimulated luminescence of aluminum oxide detectors for radiation therapy quality assurance
    Danzer, J.
    Dudney, C.
    Seibert, R.
    Robison, B.
    Harris, C.
    Ramsey, C.
    MEDICAL PHYSICS, 2007, 34 (06) : 2628 - 2629
  • [7] Establishing quality-assurance for invasive procedures
    Millat, B
    GASTROENTEROLOGIE CLINIQUE ET BIOLOGIQUE, 2001, 25 (02): : 129 - 130
  • [8] THE NEED FOR QUALIMETRY IN QUALITY-ASSURANCE PROGRAMS
    WOODS, GW
    AMERICAN CERAMIC SOCIETY BULLETIN, 1983, 62 (08): : 881 - 881
  • [9] CALIBRATION WITHIN A QUALITY-ASSURANCE SYSTEM
    不详
    WERKSTATTSTECHNIK ZEITSCHRIFT FUR INDUSTRIELLE FERTIGUNG, 1989, 79 (12): : 657 - 658
  • [10] ELEMENTS OF A LABORATORY QUALITY-ASSURANCE PROGRAM
    DRESSMAN, RC
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 1982, 74 (10): : 42 - 42