A modified low-cost colorimetric method for paracetamol (acetaminophen) measurement in plasma

被引:66
|
作者
Shihana, Fathima [1 ,2 ]
Dissanayake, Dhammika [1 ,2 ]
Dargan, Paul [3 ,4 ]
Dawson, Andrew [2 ,5 ]
机构
[1] Univ Peradeniya, Fac Med, Dept Pathol, Kandy 20000, Sri Lanka
[2] Univ Peradeniya, S Asian Clin Toxicol Res Collaborat, Peradeniya, Sri Lanka
[3] Guys & St Thomas NHS Fdn Trust, London, England
[4] Kings Hlth Partners, London, England
[5] Univ Newcastle, Sch Populat Hlth, Newcastle, NSW 2308, Australia
基金
英国惠康基金;
关键词
Acute poisoning; Acetaminophen; Acute renal failure; Analytical; Quantitative analysis; LIQUID-CHROMATOGRAPHIC DETERMINATION; AMINOPHENOL; MANAGEMENT;
D O I
10.3109/15563650903443137
中图分类号
R99 [毒物学(毒理学)];
学科分类号
100405 ;
摘要
Background. Despite a significant increase in the number of patients with paracetamol poisoning in the developing world, plasma paracetamol assays are not widely available. The purpose of this study was to assess a low-cost modified colorimetric paracetamol assay that has the potential to be performed in small laboratories with restricted resources. Methods. The paracetamol assay used in this study was based on the Glynn and Kendal colorimetric method with a few modifications to decrease the production of nitrous gas and thereby reduce infrastructure costs. Preliminary validation studies were performed using spiked aqueous samples with known concentrations of paracetamol. Subsequently, the results from the colorimetric method for 114 stored clinical samples from patients with paracetamol poisoning were compared with those from the current gold-standard high-performance liquid chromatography method. A prospective survey, assessing the clinical use of the paracetamol assay, was performed on all patients with paracetamol poisoning attending the Peradeniya General Hospital, Sri Lanka, over a 10-month period. Results. The recovery study showed an excellent correlation (r(2) > 0.998) for paracetamol concentrations from 25 to 400 mg/L. The final yellow color was stable for at least 10 min at room temperature. There was also excellent correlation with the high-performance liquid chromatography method (r(2) = 0.9758). In the clinical cohort study, use of the antidote N-acetylcysteine was avoided in over a third of patients who had the plasma paracetamol concentration measured. The cost of consumables used per assay was $0.50 (US). Conclusions. This colorimetric paracetamol assay is reliable and accurate and can be performed rapidly, easily, and economically. Use of this assay in resource-poor clinical settings has the potential to have a significant clinical and economic impact on the management of paracetamol poisoning.
引用
收藏
页码:42 / 46
页数:5
相关论文
共 50 条
  • [21] Low-cost fluorescence-based method for beer bitterness measurement
    Calado, L. S.
    Lacerda, A. L. F.
    Fiaux, S. B.
    Sphaier, L. A.
    Silva, V. N. H.
    Peixoto, F. C.
    JOURNAL OF FOOD ENGINEERING, 2019, 262 : 9 - 12
  • [22] Automated Superelevation Measurement Method Using a Low-Cost Mobile Device
    Tsai, Yichang
    Ai, Chengbo
    TRANSPORTATION RESEARCH RECORD, 2017, (2621) : 62 - 70
  • [23] A low-cost high-precision measurement method of string motion
    Le Carrou, J. -L.
    Chadefaux, D.
    Seydoux, L.
    Fabre, B.
    JOURNAL OF SOUND AND VIBRATION, 2014, 333 (17) : 3881 - 3888
  • [24] LOW-COST PORTABLE COLOR MEASUREMENT
    TULLOCH, MH
    PHOTONICS SPECTRA, 1995, 29 (02) : 18 - 18
  • [25] Low-Cost Measurement Devices for Education
    Vogt-Ardatjew R.
    Dudareva D.
    Wiid G.
    Leferink F.
    IEEE Electromagnetic Compatibility Magazine, 2023, 12 (04) : 100 - 104
  • [26] LOW-COST CONTINUOUS COMPRESSION MEASUREMENT
    ENGELMAN, HW
    MECHANICAL ENGINEERING, 1974, 96 (08) : 59 - 59
  • [27] Low-Cost NIR Measurement Device
    Mustafa, Luka
    Cerncic, Eva
    2015 4TH INTERNATIONAL WORKSHOP ON OPTICAL WIRELESS COMMUNICATIONS (IWOW), 2015, : 127 - 131
  • [28] A SENSITIVE, SPECIFIC COLORIMETRIC METHOD FOR DETERMINING PARACETAMOL IN HUMAN-PLASMA
    SCHMID, J
    FEDORCAK, A
    KOSS, FW
    KRUG, R
    SCHULER, S
    MADER, G
    ARZNEIMITTEL-FORSCHUNG/DRUG RESEARCH, 1980, 30-1 (06): : 996 - 998
  • [29] Simple, fast, and low-cost camera-based water content measurement with colorimetric fluorescent indicator
    Song, Seok-Jeong
    Kim, Tae-Il
    Kim, Youngmi
    Nam, Hyoungsik
    OPTICS AND LASER TECHNOLOGY, 2018, 101 : 545 - 553
  • [30] A low-cost automated titration system for colorimetric endpoint detection
    Boppana, Naga P. D.
    Snow, Robyn
    Simone, Paul S.
    Emmert, Gary L.
    Brown, Michael A.
    ANALYST, 2023, 148 (09) : 2133 - 2140